suhan Pyo

Mr. suhan Pyo

Dept of Electrical and Control Engineering, Mokpo National University, Korea
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2023 in Energies
Verified
Journal Article
Open access
PDF file
JCJunsoo Che
Junsoo Che
TKTae-Hun Kim
Tae-Hun Kim
SPsuhan Pyo
suhan Pyo
JPJaedoek Park
Jaedoek Park
BAByeongHyeon An
ByeongHyeon An
TPTaesik Park
Taesik Park
Overhead lines that are exposed to the outdoors are susceptible to faults such as open conductors on weak points and disconnection caused by external factors such as typhoons. Arcs that occur during disconnection generate energy at a high heat of over 10,000 °C, requiring swift fault shut-off. However, most conventional fault detection methods to protect electrical power systems detect an overcurrent; thus, they can only detect faults after the line is disconnected and the cross-section of the line that generates the arc discharge makes contact with another line or the ground, causing a high risk of fire. Furthermore, in the case of ground faults owing to the disconnection of overhead lines, the load and the grounding impedance are not parallel. Therefore, in the case of the fault current not exceeding the threshold or a high impedance fault due to the high grounding impedance of the surrounding environment, such as grass or trees, it is difficult to determine overhead line faults with conventional fault detection methods. To solve these issues, this paper proposes an AI-based open conductor fault detection method on overhead lines that can clear the fault before the falling open conductor line comes into contact with the ground’s surface so as to prevent fire. The falling time according to the height and span of the overhead line was calculated using a falling conductor model for the overhead line, to which the pendulum motion was applied. The optimal input data cycle that enables fault detection before a line–ground fault occurs was derived. For artificial intelligence learning to prevent wildfires, the voltage and current signals were collected through a total of 432 fault simulations and were wavelet-transformed with a deep neural network to verify the method. The proposed total scheme was simulated and verified with MATLAB.

26 February 2022 in Energies
Verified
Journal Article
Open access
PDF file
SPsuhan Pyo
suhan Pyo
TKTae-Hun Kim
Tae-Hun Kim
BAByeongHyeon An
ByeongHyeon An
JPJaedoek Park
Jaedoek Park
JPJang-Hyun Park
Jang-Hyun Park
TPTaesik Park
Taesik Park
Recently, because of the increase in the number of connections to Distributed Generation (DG), the problem of lowering voltage stability in the distribution system has become an issue. Reactive power compensators, such as Static Synchronous Compensators (STATCOM), may be used to solve the problem of voltage stability degradation. However, because of the complexity of the distribution system, it is very difficult to select the installation location for STATCOM. Furthermore, when installed in the wrong location, economical efficiency and availability problems may occur. This paper proposes a Virtual STATCOM Configuration and Control method that would operate like a single STATCOM based on multiple DGs connected to the system. The proposed Virtual STATCOM has the merit of being economical by using existing facilities without adding new power facilities, and it solves the problem of the difficulty of selecting the installation location because of the complexity of the distribution system. In addition, while the conventional STATCOM uses an independent control method in consideration of the power quality of the access point, the Virtual STATCOM performs the Point of Common Coupling (PCC) power quality compensation using the integrated control of multiple DGs connected to the system. In the proposed method, the Virtual STATCOM integrated control algorithm is configured by adopting linear programming, and the compensation is performed while considering the distance between DG and PCC, the inverter’s rated capacity, and the power generation. The performance of the Virtual STATCOM power quality compensation was verified using MATLAB/SIMULINK and Real Time Simulator (OPAL-RT).

13 December 2024 in IEEE Access
Verified
Journal Article
Open access
JCJunsoo Che
Junsoo Che
GPGihun Park
Gihun Park
JOJeongsik Oh
Jeongsik Oh
SPsuhan Pyo
suhan Pyo
BAByeongHyeon An
ByeongHyeon An
TPTaesik Park
Taesik Park
Power companies employ comprehensive evaluations to manage facilities, such as transformers, lines, and generators, assessing their status and calculating the probability of failure. Within this asset management framework, a key metric that indicates the condition of facilities is the health index. To develop an optimal investment strategy for facility maintenance and management, a method for accurately calculating the health index is essential. Recent studies have explored the application of machine learning to improve accuracy. However, these studies ignore the risk of misclassification, which can result in significant financial losses when predicting the health index of power transformers. Therefore, this study proposes a health index calculation algorithm that incorporates cost-sensitive learning to assess the impact of each misclassification scenario, construct a cost matrix, and minimize the cost through learning. Input parameters are selected on the basis of the power transformer’s structure, failure mode effect analysis, failure diagnosis techniques, and historical failure cases. During the learning process, the relationship between actual and predicted classes is analyzed, and the risk associated with each misclassification scenario is quantified to describe the cost matrix. The effectiveness of the proposed health index calculation algorithm is validated using in-service power transformer inspection data, demonstrating a reduction in the risk of specific misclassification scenarios.

12 November 2021 in Journal of Electrical Engineering & Technology
Verified
Journal Article
Closed access
PDF file
SPsuhan Pyo
suhan Pyo
JOJeong-Sik Oh
Jeong-Sik Oh
TKTae-Hun Kim
Tae-Hun Kim
JCJun-Soo Che
Jun-Soo Che
JPJang-Hyun Park
Jang-Hyun Park
TPTaesik Park
Taesik Park

9 December 2025 in Energies
Verified
Journal Article
Open access
PDF file
TKTae-Hun Kim
Tae-Hun Kim
WHWon-Cheol Hong
Won-Cheol Hong
SPsuhan Pyo
suhan Pyo
BAByeongHyeon An
ByeongHyeon An
TPTaesik Park
Taesik Park
This paper presents a Field-Programmable Gate Array (FPGA)-based Hardware-in-the-Loop (HIL) simulation of an Interleaved Boost Power Factor Correction (PFC) converter using the Sub-Cycle Average (SCA) modeling technique. The main objective is to achieve accurate real-time simulation performance given the hardware constraints of low-cost FPGAs. By combining the SCA modeling approach with a time-averaging correction method, the proposed model effectively reduces sampling delays and duty-cycle estimation errors arising from asynchronous Pulse Width Modulation (PWM) signal acquisition. The SCA-based converter model and time-averaging correction technique were implemented in MATLAB/Simulink R2024b using the HDL Coder environment. To validate real-time simulation accuracy, power factor improvement was evaluated for a two-phase Interleaved Boost PFC operating at a switching frequency of 60 kHz. Experimental results confirm that the proposed approach enables accurate Controller–HIL testing of power converters, even when implemented on low-cost FPGA platforms such as the Zybo Z7-10 evaluation board.