Choong-Min Kang

Dr. Choong-Min Kang

Environmental Health Department, Harvard T.H. Chan School of Public Health, Harvard University, Boston, MA 02215, USA
orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 October 2014 in Particle and Fibre Toxicology
Verified
Journal Article
Open access
PDF file
ABAndrea Baccarelli
Andrea Baccarelli
YZYinan Zheng
Yinan Zheng
XZXiao Zhang
Xiao Zhang
DCDou Chang
Dou Chang
LLLei Liu
Lei Liu
LHLifang Hou
Lifang Hou
Exposure to ambient particulate matter (PM) has been associated with reduced lung function. Elemental components of PM have been suggested to have critical roles in PM toxicity, but their contribution to respiratory effects remains under-investigated. We evaluated the effects of traffic-related PM2.5 and its elemental components on lung function in two highly exposed groups of healthy adults in Beijing, China. The Beijing Truck Driver Air Pollution Study (BTDAS) included 60 truck drivers and 60 office workers evaluated in 2008. On two days separated by 1-2 weeks, we measured lung function at the end of the work day, personal PM2.5, and nine elemental components of PM2.5 during eight hours of work, i.e., elemental carbon (EC), potassium (K), sulfur (S), iron (Fe), silicon (Si), aluminum (Al), zinc (Zn), calcium (Ca), and titanium (Ti). We used covariate-adjusted mixed-effects models including PM2.5 as a covariate to estimate the percentage change in lung function associated with an inter-quartile range (IQR) exposure increase. The two groups had high and overlapping exposure distributions with mean personal PM2.5 of 94.6 μg/m3 (IQR: 48.5-126.6) in office workers and 126.8 μg/m3 (IQR: 73.9-160.5) in truck drivers. The distributions of the nine elements showed group-specific profiles and generally higher levels in truck drivers. In all subjects combined, forced expiratory volume in 1 second (FEV1) and forced vital capacity (FVC) did not significantly correlate with PM2.5. However, FEV1 showed negative associations with concentrations of four elements: Si (-3.07%, 95% CI: -5.00; -1.11, IQR: 1.54), Al (-2.88%, 95% CI: -4.91; -0.81, IQR: 0.86), Ca (-1.86%, 95% CI: -2.95; -0.76, IQR: 1.33), and Ti (-2.58%, 95% CI: -4.44; -0.68, IQR: 0.03), and FVC showed negative associations with concentrations of three elements: Si (-3.23%, 95% CI: -5.61; -0.79), Al (-3.26%, 95% CI: -5.73; -0.72), and Ca (-1.86%, 95% CI: -3.23; -0.47). In stratified analysis, Si, Al, Ca, and Ti showed associations with lung function only among truck drivers, and no significant association among office workers. Selected elemental components of PM2.5 showed effects on lung function that were not found in analyses of particle levels alone.

Mei ChungMei Chung
Mei Chung
DWDing Ding Wang
Ding Ding Wang
ARAmanda M. Rizzo
Amanda M. Rizzo
DGDarrel Gachette
Darrel Gachette
MDMarie Delnord
Marie Delnord
Doug  BruggeDoug Brugge
Doug Brugge
Elevated blood pressure is an indicator of cardiovascular stress and increased risk of cardiovascular-related morbidity and mortality. There is emerging evidence suggesting air pollutants, including particulate matter (PM), could promote hypertension, thereby increasing cardiovascular disease risk. Repeated measurement analyses were conducted to examine the associations of three types of PM with systolic blood pressure (SBP), diastolic blood pressure (DBP), and pulse pressure (PP) in 220 participants, (mean age = 58.5 years) from the Community Assessment of Freeway Exposure and Health study (CAFEH), most of whom live near a major highway. Ambient levels of air pollutants including particle number concentration (PNC; a measure of ultrafine particle (UFP) concentration), fine PM (PM2.5, Particle diameter <2.5 µm), and black carbon (BC) were measured at a central site <7 km from the study areas. Central sites are good at capturing short-term temporal trends in pollution associated with meteorological changes over regional areas. Linear mixed-effect models that accounted for repeated measures within one person were used to examine the associations between blood pressure variables and daily average of ambient PNC, PM2.5, or BC, controlling for demographic characteristics and major confounders including temperature. Our PNC model predicted that a higher PNC of 10,000 particles/cm3 was associated with higher DBP of 2.40 mmHg (p = 0.03), independent of other factors in the model. There were no significant associations for PM2.5 or BC. Post hoc subgroup analyses by obesity status showed that positive associations of DBP with PNC were more pronounced among obese individuals than non-obese individuals. These results suggested that PNC levels are associated with increased blood pressure, which may contribute to cardiovascular disease risk. More research is needed to assess the relationship between PNC and blood pressure and to address possible residual confounding.

1 April 2022 in Environmental Health Perspectives
Verified
Journal Article
Closed access
VMVasileios N. Matthaios
Vasileios N. Matthaios
Choong-Min KangChoong-Min Kang
Choong-Min Kang
JWJack M. Wolfson
Jack M. Wolfson
KGKimberly F. Greco
Kimberly F. Greco
JGJonathan M. Gaffin
Jonathan M. Gaffin
PKPetros Koutrakis
Petros Koutrakis

YYYufei Yuan
Yufei Yuan
BABarrak Alahmad
Barrak Alahmad
Choong-Min KangChoong-Min Kang
Choong-Min Kang
FAFhaid Almarri
Fhaid Almarri
VKVenkateswarlu Kommula
Venkateswarlu Kommula
PKPetros Koutrakis
Petros Koutrakis
Kuwait is a developed Middle Eastern country that is impacted by frequent dust storms from regional and/or remote deserts. The effectiveness of keeping homes tightly closed during these events to reduce dust exposures was assessed using indoor and outdoor particle samples at 10 residences within the metropolitan Kuwait City area. Specifically, this study compared indoor and outdoor levels of black carbon and 19 trace elements (Na, Mg, Al, Si, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Br, Sr, and Zr) during dust and non-dust events and found that particle penetration efficiencies were lower during dust storm events (less than 20–30%) than during non-dust storm events (40–60%). Coarse particles had lower penetration efficiency compared to fine particles, which is due to differences in infiltration rates and settling velocities between these two size fractions. Our findings suggest that increasing home insulation could be an effective strategy to reduce indoor exposure to crustal particles from dust storm events in residential houses of Kuwait City.

1 October 2014 in Atmospheric Environment
Verified
Journal Article
Closed access
Choong-Min KangChoong-Min Kang
Choong-Min Kang
DGDiane Gold
Diane Gold
PKPetros Koutrakis
Petros Koutrakis

1 January 2020 in Aerosol and Air Quality Research
Verified
Journal Article
Open access
PDF file
Choong-Min KangChoong-Min Kang
Choong-Min Kang
MLMan Liu
Man Liu
EGEric Garshick
Eric Garshick
PKPetros Koutrakis
Petros Koutrakis
Exposure to radioactivity inside homes potentially poses severe health risks which can be exacerbated by the interaction between radioactive particles and fine indoor particles; in particular, the presence of α particles are a key risk factor. Hence, in this study, particle radioactivity was concurrently measured in the family rooms and basements of 26 homes to assess its concentrations and identify its sources, both indoors and outdoors, across two seasons. The levels of radon, air ions, and particle radioactivity, which included short- and long-lived α-activity (SLA and LLA, respectively), varied greatly but were substantially higher in the basements. Also, particle radioactivity—as well as PM2.5 and sulfur concentrations—were lower during the heating season. SLA was associated with radon, which was consistently of indoor origin, whereas LLA was more strongly related to the sulfur measured in indoor PM2.5, which is a proxy of outdoor infiltration. A regression model adjusted for sulfur and SLA also indicated a predominance of outdoor sources, likely due to the short residence time of indoor particles. Our results suggest that radiation in homes originates from both the decay of indoor radon and the infiltration of outdoor radioactivity.