Photovoltaic (PV) arrays are prone to various faults due to the hostile working environment. This paper presents the fault diagnosis algorithm based on support vector machine (SVM) to detect short circuit, open circuit, and lack of irradiation faults that occurred in PV arrays. By analyzing these faults and I–V characteristic curves of PV arrays, the short-circuit current, open-circuit voltage, maximum-power current, and maximum-power voltage are chosen as input parameters of SVM-based fault diagnosis algorithm. The data preprocessing methods are used to improve the quality of fault data set considering the effects of the quality on the performance of SVM-based fault diagnosis algorithm. The grid search and k-fold cross-validation methods are proposed to optimize the parameters of the SVM-based fault diagnosis algorithm. It gets test accuracy of 97% by testing the trained SVM-based fault diagnosis algorithm with 400 data. The experimental results indicate that the SVM-based fault diagnosis algorithm has higher accuracy and generalization ability than other algorithm for fault diagnosis of PV arrays.
18 July 2012 in Chinese Journal of Mechanical Engineering
Needle insertion is a widely used medical procedure in various minimally invasive surgeries. The estimation of the coupled needle deflection and tissue deformation during the needle insertion procedure is crucial to the success of the surgery. In this work, a novel needle deflection–tissue deformation coupling model is proposed for flexible needle insertion into soft tissue. Based on the assumption that the needle deflection is small comparing to the length of the insertion, the needle–tissue interaction model is developed based on the modified local constraint method, where the interactive forces between the needle and the tissue are balanced through integration of needle–force and tissue–force relationships. A testbed is constructed and the experiments are designed to validate the proposed method using artificial phantom with markers. Based on the experimental analysis, the cutting and friction forces are separated from the force–time curves and used as the inputs into the proposed model. The trajectories of the markers inside the soft tissue are recorded by a CCD camera to compare with the simulation trajectories. The errors between the experimental and simulation trajectories are less than 0.8 mm. The results demonstrate that the proposed method is effective to model the needle insertion procedure.
10 March 2021 in Computer Methods in Biomechanics and Biomedical Engineering
Needle-tissue interaction model is essential to tissue deformation prediction, interaction force analysis and needle path planning system. Traditional FEM based needle-tissue interaction model would encounter mesh distortion or continuous mesh subdivision in dealing with penetration, in which the computational instability and poor accuracy could be introduced. In this work, a novel material point method (MPM) is applied to establish the needle-tissue interaction model which is suitable to handle the discontinuous penetration problem. By integrating a hyperelastic material model, the tissue deformation and interaction force can be solved simultaneously and independently. A testbed of needle insertion into a Polyvinyl alcohol (PVA) hydrogel phantom was constructed to validate both tissue deformation and interaction force. The results showed the experimental data agrees well with the simulation results of the proposed model.
In order to get to the desired target inside the body, it is essential to investigate the needle-tissue coupling process and calculate the tissue deformation. A cantilever beam model is presented to predicting the deflection and bending angle of flexible needle by analyzing the distribution of the force on needle shaft during the procedure of needle insertion into soft tissue. Furthermore, a finite element (FE) coupling model is proposed to simulate the needle-tissue interactive process. The plane and spatial models are created to relate the needle and tissue nodes. Combined with the cantilever beam model and the finite element needle-tissue coupling model, the simulation of needle-tissue interaction was carried out by the ABAQUS software. The comparing experiments are designed to understand the needle-tissue interactions, by which the same points in the experiments and simulation are compared and analyzed. The results show that the displacements in x and z directions in the simulation can accord with the experiments, and the deformation inside the tissue mainly occurs in the axial direction. The study is beneficial to the robotassisted and virtual needle insertion procedure, and to help the physicians to predict the inside tissue deformation during the treatments.