Rui Oliveira-Silva

Dr. Rui Oliveira-Silva

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 May 2016 in Nanotoxicology
Verified
Journal Article
Closed access
JCJoana Carrola
Joana Carrola
Verónica BastosVerónica Bastos
Verónica Bastos
Ivana JarakIvana Jarak
Ivana Jarak
Rui Oliveira-SilvaRui Oliveira-Silva
Rui Oliveira-Silva
EMEliana Malheiro
Eliana Malheiro
Iola F. DuarteIola F. Duarte
Iola F. Duarte
The widespread use of silver nanoparticles (AgNPs) is accompanied by a growing concern regarding their potential risks to human health, thus calling for an increased understanding of their biological effects. The aim of this work was to systematically study the extent to which changes in cellular metabolism were dependent on the properties of AgNPs, using NMR metabolomics. Human skin keratinocytes (HaCaT cells) were exposed to citrate-coated AgNPs of 10, 30 or 60 nm diameter and to 30 nm AgNPs coated either with citrate (CIT), polyethylene glycol (PEG) or bovine serum albumin (BSA), to assess the influence of NP size and surface chemistry. Overall, CIT-coated 60 nm and PEG-coated 30 nm AgNPs had the least impact on cell viability and metabolism. The role of ionic silver and reactive oxygen species (ROS)-mediated effects was also studied, in comparison to CIT-coated 30 nm particles. At concentrations causing an equivalent decrease in cell viability, Ag+ ions produced a change in the metabolic profile that was remarkably similar to that seen for AgNPs, the main difference being the lesser impact on the Krebs cycle and energy metabolism. Finally, this study newly reported that while down-regulated glycolysis and disruption of energy production were common to AgNPs and H2O2, the impact on some metabolic pathways (GSH synthesis, glutaminolysis and the Krebs cycle) was independent of ROS-mediated mechanisms. In conclusion, this study shows the ability of NMR metabolomics to define subtle biochemical changes induced by AgNPs and demonstrates the potential of this approach for rapid, untargeted screening of pre-clinical toxicity of nanomaterials in general.

27 October 2014 in Journal of Materials Chemistry B
Verified
Journal Article
Closed access
PDF file
Rui Oliveira-SilvaRui Oliveira-Silva
Rui Oliveira-Silva
Joao Pinto da CostaJoao Pinto da Costa
Joao Pinto da Costa
Rui VitorinoRui Vitorino
Rui Vitorino
Ana Luísa Daniel-da-SilvaAna Luísa Daniel-da-Silva
Ana Luísa Daniel-da-Silva
Magnetic nanoparticles effective in the selective recovery of metalloproteases from human saliva were fabricated by surface modification of Fe3O4@SiO2nanoparticles with EDTA-TMS.

12 March 2018 in Sensors
Verified
Journal Article
Open access
PDF file
ABAna Bastos
Ana Bastos
Carlos VicenteCarlos Vicente
Carlos Vicente
Rui Oliveira-SilvaRui Oliveira-Silva
Rui Oliveira-Silva
NSNuno Joao Silva
Nuno Joao Silva
MTMarta Tacão
Marta Tacão
Rute FerreiraRute Ferreira
Rute Ferreira
The development of portable low-cost integrated optics-based biosensors for photonics-on-a-chip devices for real-time diagnosis are of great interest, offering significant advantages over current analytical methods. We report the fabrication and characterization of an optical sensor based on a Mach-Zehnder interferometer to monitor the growing concentration of bacteria in a liquid medium. The device pattern was imprinted on transparent self-patternable organic-inorganic di-ureasil hybrid films by direct UV-laser, reducing the complexity and cost production compared with lithographic techniques or three-dimensional (3D) patterning using femtosecond lasers. The sensor performance was evaluated using, as an illustrative example, E. coli cell growth in an aqueous medium. The measured sensitivity (2 × 10−4 RIU) and limit of detection (LOD = 2 × 10−4) are among the best values known for low-refractive index contrast sensors. Furthermore, the di-ureasil hybrid used to produce this biosensor has additional advantages, such as mechanical flexibility, thermal stability, and low insertion losses due to fiber-device refractive index mismatch (~1.49). Therefore, the proposed sensor constitutes a direct, compact, fast, and cost-effective solution for monitoring the concentration of lived-cells.

11 July 2015 in Journal of Nanoparticle Research
Verified
Journal Article
Closed access
PDF file
Ana Luísa Daniel-da-SilvaAna Luísa Daniel-da-Silva
Ana Luísa Daniel-da-Silva
ACAna Margarida Martins Salgueiro Carta
Ana Margarida Martins Salgueiro Carta
BCBianca Creaney
Bianca Creaney
Rui Oliveira-SilvaRui Oliveira-Silva
Rui Oliveira-Silva
NSNuno Joao Silva
Nuno Joao Silva
Tito TrindadeTito Trindade
Tito Trindade

8 May 2015 in Proteomics – Clinical Applications
Verified
Journal Article
Closed access
FTFábio Trindade
Fábio Trindade
FAFrancisco Amado
Francisco Amado
Rui Oliveira-SilvaRui Oliveira-Silva
Rui Oliveira-Silva
Ana Luísa Daniel-da-SilvaAna Luísa Daniel-da-Silva
Ana Luísa Daniel-da-Silva
RFRita Ferreira
Rita Ferreira
Rui VitorinoRui Vitorino
Rui Vitorino

1 July 2020 in Trends in Biochemical Sciences
Verified
Journal Article
Closed access
Rui Oliveira-SilvaRui Oliveira-Silva
Rui Oliveira-Silva
MSMariana Sousa-Jerónimo
Mariana Sousa-Jerónimo
DBDavid Botequim
David Botequim
NSNuno J.O. Silva
Nuno J.O. Silva
PPPedro M. R. Paulo
Pedro M. R. Paulo
Duarte Miguel PrazeresDuarte Miguel Prazeres
Duarte Miguel Prazeres