Santiago Eizaguirre

Mr. Santiago Eizaguirre


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 October 2021 in Advanced Materials Technologies
Verified
Journal Article
Open access
PDF file
QJQihao Jin
Qihao Jin
QZQiaoshuang Zhang
Qiaoshuang Zhang
JCJunchi Chen
Junchi Chen
TGTim Gehring
Tim Gehring
SESantiago Eizaguirre
Santiago Eizaguirre
RKRainer Kling
Rainer Kling
Mechanoresponsive smart windows have been intensively investigated in recent years as they offer various applications for signage and light management. However, integrating a display functionality into such smart windows remains a challenge since the realization of pixels in these devices is difficult. In addition, mechanoresponsive smart windows with a high dynamic range are rarely demonstrated because they would suffer from complex fabrication processes and high costs. In this work, a novel surface modification process and digital encoding were developed for direct inkjet printing of micro‐etching‐masks on hydrophobic elastomers, and a pixelated haze distribution was realized. Compared to the traditional mechanoresponsive smart windows, which modify the optical performance by applied strain solely, here, a smart window with haze tunability in either static or strain‐applied state is demonstrated. The work enhances the potential of the fabricated smart window to be applied in high dynamic range signage displays.

1 February 2022 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
SESantiago Eizaguirre
Santiago Eizaguirre
TGTim Gehring
Tim Gehring
FDFabian Denk
Fabian Denk
QJQihao Jin
Qihao Jin
JDJan Dycke
Jan Dycke
RKRainer Kling
Rainer Kling
Wide band-gap resonant converters operating with zero voltage switching (ZVS) recently proved the conversion of up to $25 \,\mathrm{k}\mathrm{W}$ at $3 \,\mathrm{M}\mathrm{Hz}$ with an efficiency of $\approx$$94 \%$. This is of special interest for any application where power in middle frequency range is required since typically achieved efficiencies for those frequencies are in the range of $60\% \hbox{--}70\%$. Inductively coupled plasma (ICP) based applications would significantly benefit from this fact, but they entail special driving challenges. ICP loads exhibit strong impedance variations during ignition and operation, which means a high limitation factor when driving them with resonant converters. This article offers a deeper look into this topic through the example of a $10 \,\mathrm{Pa}$ Xenon lamp. The ignition transient is measured and analyzed while driving the system with a Silicon Carbide (SiC)-based resonant converter. An FEM simulation modeling the electromagnetic, thermal, mechanical, and plasma properties is also performed. The results are contrasted with the corresponding measurements showing as well the simulation usefulness as a design tool. Theoretical calculations of the intrinsic limits for ZVS resonant power conversion are also offered. This provides an insight into which analysis and control methods would make ICP loads compatible with these converters and, therefore, able to benefit completely from their efficiency and power density benefits.

31 December 2019 in Plasma
Verified
Journal Article
Open access
PDF file
TGTim Gehring
Tim Gehring
FDFabian Denk
Fabian Denk
QJQihao Jin
Qihao Jin
SESantiago Eizaguirre
Santiago Eizaguirre
RKRainer Kling
Rainer Kling
In this paper, an efficient inductively coupled medium pressure source for ultraviolet radiation (UV-source) is demonstrated. The lamp was operated with powers up to 3 kW while the radiation and the coldest point temperature were measured. In addition, different coil geometries were investigated. Here a symmetrical and asymmetrical winding density were compared. Also the operation pressures and DC to radiation efficiencies are presented. In this work, an operation pressure of one atmosphere and an UV-efficiency (200–380 nm) of 15.5% was achieved. This is comparable to conventional medium pressure Hg-lamp technology. The main advantage of the presented inductive lamp is the electrodeless operation and therefore the longer service life, since an electrode failure is eliminated.

16 August 2019 in Plasma
Verified
Journal Article
Open access
PDF file
TGTim Gehring
Tim Gehring
QJQihao Jin
Qihao Jin
FDFabian Denk
Fabian Denk
SESantiago Eizaguirre
Santiago Eizaguirre
DKDavid Karcher
David Karcher
RKRainer Kling
Rainer Kling
Inductive plasma discharge has been a part of continuous investigations since it was discovered. Especially the E- to H-mode transition and the hysteresis behavior have been topics of research in the last few decades. In this paper, we demonstrate a way to reduce the hysteresis behavior by the usage of a microwave ignition system. With this system, a significant decrease of the needed coil current for the ignition of the inductive driven plasma is realized. For the microwave generation, a magnetron as in a conventional microwave oven is used, which offers a relatively inexpensive way for microwave ignition aid. At the measured pressure of 7.5 Pa, it was possible to reduce the needed coil current for the inductive mode transition by a factor of 3.75 compared to the mode transition current without the ignition aid. This was achieved by initiating the transition by a few seconds of microwave coupling. The performed simulations suggested that the factor can be further increased at higher pressures. That is especially interesting for plasmas that are hard to ignite or for RF-sources that cannot deliver high enough currents or frequencies for the ignition.

20 July 2019 in Energies
Verified
Journal Article
Open access
PDF file
MHMichael Heidinger
Michael Heidinger
QXQihao Xia
Qihao Xia
CSChristoph Simon
Christoph Simon
FDFabian Denk
Fabian Denk
SESantiago Eizaguirre
Santiago Eizaguirre
WHWolfgang Heering
Wolfgang Heering
This paper introduces a control algorithm for soft-switching series LC converters. The conventional voltage-to-voltage controller is split into a master and a slave controller. The master controller implements constant current, constant voltage (CCCV) control, required for demanding applications, for example, lithium battery charging or laboratory power supplies. It defines the set-current for the open-loop current slave controller, which generates the pulse width modulation (PWM) parameters. The power supply achieves fast large-signal responses, e.g., from 5 V to 24 V , where 95% of the target value is reached in less than 400 s . The design is evaluated extensively in simulation and on a prototype. A match between simulation and measurement is achieved.

16 November 2021 in Plasma
Verified
Journal Article
Open access
PDF file
TGTim Gehring
Tim Gehring
SESantiago Eizaguirre
Santiago Eizaguirre
QJQihao Jin
Qihao Jin
JDJan Dycke
Jan Dycke
MRManuel Renschler
Manuel Renschler
RKRainer Kling
Rainer Kling
Inductively Coupled Plasma (ICP) discharges are part of intense research. Predicting different plasma parameters, like the distribution and temperature of the present species, is of great interest for many applications. Iodine- or halide-containing plasmas in particular have an important function, for example, in the development of mercury-free UV radiation sources. Therefore, a 2D simulation model of a xenon- and iodine-containing ICP was created by using the Finite Element Method (FEM) software COMSOL Multiphysics®. The included species and the used reactions are presented in this paper. To verify the simulation in relation to the plasma distribution, the results were compared with measurements from literature. The temperature of the lamp vessel was measured in relation to the temperature distribution and also compared with the results of the simulation. It could be shown that the simulation reproduces the plasma distribution with a maximal deviation of ≈6.5% to the measured values and that the temperature distribution in the examined area can be predicted with deviations of up to ≈24% for long vessel dimensions and ≈3% for shorter dimensions. However, despite the deviating absolute values, the general plasma behaviour is reproduced by the simulation. The simulation thus offers a fast and cost-effective method to estimate an effective geometrical range of iodine-containing ICPs.