Huiqiang Li

Prof. Huiqiang Li

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 December 2017 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
YBYing Bian
Ying Bian
CLChangshan Liu
Changshan Liu
TSTiantian She
Tiantian She
MWMengjuan Wang
Mengjuan Wang
JYJuanjuan Yan
Juanjuan Yan
HLHuiqiang Li
Huiqiang Li

1 June 2016 in Molecular Immunology
Verified
Journal Article
Closed access
YZYingying Zhang
Yingying Zhang
LZLina Zhu
Lina Zhu
SLShaoshen Li
Shaoshen Li
JZJiayi Zhang
Jiayi Zhang
TSTiantian She
Tiantian She
HLHuiqiang Li
Huiqiang Li

26 November 2018 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
YCYaqiong Cui
Yaqiong Cui
TSTiantian She
Tiantian She
HZHong Zhao
Hong Zhao
JLJiuzhi Li
Jiuzhi Li
LLLiuxu Li
Liuxu Li
HLHuiqiang Li
Huiqiang Li

1 August 2018 in International Immunopharmacology
Verified
Journal Article
Closed access
JLJunpu Li
Junpu Li
JZJiayi Zhang
Jiayi Zhang
CQCuiya Qiong
Cuiya Qiong
TSTiantian She
Tiantian She
YBYing Bian
Ying Bian
HLHuiqiang Li
Huiqiang Li

1 January 2019
Verified
Journal Article
Closed access
SGShi-zhen Guan
Shi-zhen Guan
YYYa-qiong Yang
Ya-qiong Yang
XBXue Bai
Xue Bai
YWYi Wang
Yi Wang
KFKai-qiang Feng
Kai-qiang Feng
HLHuiqiang Li
Huiqiang Li

15 June 2020 in Molecular Medicine Reports
Verified
Journal Article
Open access
PDF file
GSGuang Sun
Guang Sun
JXJinmei Xue
Jinmei Xue
LLLiuxu Li
Liuxu Li
XLXue Li
Xue Li
YCYaqiong Cui
Yaqiong Cui
HLHuiqiang Li
Huiqiang Li
Quantification of testosterone serves an important role in the differential diagnosis of androgen‑related endocrine diseases. Mass spectrometry exhibits higher accuracy and lower variability than immunoassays, especially at low testosterone concentrations. The present study developed and validated an isotope dilution ultra‑performance liquid chromatography tandem mass spectrometry method for determination of human serum testosterone. The serum was equilibrated with an isotopic internal standard and treated with acidic buffer to release hormones from their binding proteins. Testosterone was extracted via two serial liquid‑liquid extractions. In the first stage, the lipid fractions from an acidic buffer solution were isolated using ethyl acetate and n‑hexane. The organic phase was evaporated and reconstituted in a basic buffer solution. In the second stage, the polar impurities of n‑hexane extraction were removed. Total testosterone in serum was quantified via ultra‑performance liquid chromatography tandem mass spectrometry in multiple reaction monitoring mode with positive electrospray ionization. The coefficient of variation of the method for intra‑ and inter‑assay was 2.13% (1.40‑2.77%) and 3.44% (3.06‑3.66%), respectively. The recovery ranged from 94.32 to 108.60% for different samples. The limit of detection was 0.50 ng/dl and the linear range was from 1.00 to 1,000.00 ng/dl. In addition, the extraction efficiency in three different levels of quality control of the serum ranged from 85.02 to 93.29%. Moreover, structural analogues were investigated and were not indicated to affect the quantification of testosterone. The present method may enable quantification of testosterone in a clinical setting with high precision and accuracy.