Anna Pasynkova

Dr. Anna Pasynkova

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2018 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
NBNikita Buznikov
Nikita Buznikov
ASA.P. Safronov
A.P. Safronov
IOI. Orue
I. Orue
EGE.V. Golubeva
E.V. Golubeva
VLV.N. Lepalovskij
V.N. Lepalovskij
Galina V. KurlyandskayaGalina V. Kurlyandskaya
Galina V. Kurlyandskaya

1 June 2017 in Biochimica et Biophysica Acta (BBA) - General Subjects
Verified
Journal Article
Closed access
Galina V. KurlyandskayaGalina V. Kurlyandskaya
Galina V. Kurlyandskaya
DPDmitriy S. Portnov
Dmitriy S. Portnov
IBIgor V. Beketov
Igor V. Beketov
Aitor LarrañagaAitor Larrañaga
Aitor Larrañaga
ASAlexander P. Safronov
Alexander P. Safronov
ASAndrey Svalov
Andrey Svalov

17 August 2017 in Sensors
Verified
Journal Article
Open access
PDF file
APAnna Pasynkova
Anna Pasynkova
VLVladimir N Lepalovskij
Vladimir N Lepalovskij
MDMichael Derevyanko
Michael Derevyanko
MDMichael Derevyanko
Michael Derevyanko
VLVladimir N. Lepalovsky
Vladimir N. Lepalovsky
Galina V. KurlyandskayaGalina V. Kurlyandskaya
Galina V. Kurlyandskaya
Permalloy-based thin film structures are excellent materials for sensor applications. Temperature dependencies of the magnetic properties and giant magneto-impedance (GMI) were studied for Fe19Ni81-based multilayered structures obtained by the ion-plasma sputtering technique. Selected temperature interval of 25 °C to 50 °C corresponds to the temperature range of functionality of many devices, including magnetic biosensors. A (Cu/FeNi)5/Cu/(Cu/FeNi)5 multilayered structure with well-defined traverse magnetic anisotropy showed an increase in the GMI ratio for the total impedance and its real part with temperature increased. The maximum of the GMI of the total impedance ratio ΔZ/Z = 56% was observed at a frequency of 80 MHz, with a sensitivity of 18%/Oe, and the maximum GMI of the real part ΔR/R = 170% at a frequency of 10 MHz, with a sensitivity of 46%/Oe. As the magnetization and direct current electrical resistance vary very little with the temperature, the most probable mechanism of the unexpected increase of the GMI sensitivity is the stress relaxation mechanism associated with magnetoelastic anisotropy.

4 March 2014 in Langmuir
Verified
Journal Article
Closed access
ASA. P. Safronov
A. P. Safronov
Galina V. KurlyandskayaGalina V. Kurlyandskaya
Galina V. Kurlyandskaya
APAnna Pasynkova
Anna Pasynkova
MKM. V. Kuznetsov
M. V. Kuznetsov
Denis N BazhinDenis N Bazhin
Denis N Bazhin
AMA. Martinez-Amesti
A. Martinez-Amesti

26 April 2022 in Sensors
Verified
Journal Article
Open access
PDF file
SKSergey Komogortsev
Sergey Komogortsev
IVIrina G. Vazhenina
Irina G. Vazhenina
SKSofya A. Kleshnina
Sofya A. Kleshnina
RIRauf Iskhakov
Rauf Iskhakov
VLVladimir N Lepalovskij
Vladimir N Lepalovskij
ASAndrey Svalov
Andrey Svalov
Magnetometry and ferromagnetic resonance are used to quantitatively study magnetic anisotropy with an easy axis both in the film plane and perpendicular to it. In the study of single-layer and multilayer permalloy films, it is demonstrated that these methods make it possible not only to investigate the average field of perpendicular and in-plane anisotropy, but also to characterize their inhomogeneity. It is shown that the quantitative data from direct integral and local measurements of magnetic anisotropy are consistent with the direct and indirect estimates based on processing of the magnetization curves. The possibility of estimating the perpendicular magnetic anisotropy constant from the width of stripe domains in a film in the transcritical state is demonstrated. The average in-plane magnetic anisotropy field of permalloy films prepared by magnetron sputtering onto a Corning glass is almost unchanged with the thickness of a single-layer film. The inhomogeneity of the perpendicular anisotropy field for a 500 nm film is greater than that for a 100 nm film, and for a multilayer film with a total permalloy thickness of 500 nm, it is greater than that for a homogeneous film of the same thickness.

1 September 2015 in Vacuum
Verified
Journal Article
Closed access
ASAndrey Svalov
Andrey Svalov
BAB. González Asensio
B. González Asensio
APAnna Pasynkova
Anna Pasynkova
PSP.A. Savin
P.A. Savin
Aitor LarrañagaAitor Larrañaga
Aitor Larrañaga
Galina V. KurlyandskayaGalina V. Kurlyandskaya
Galina V. Kurlyandskaya