Urban environments are characterized by dense development and paved ground with reduced evapotranspiration rates. These areas store sensible and latent heat, providing the base for typical urban heat island effects. Green roof installations are one possible strategy to reintroduce evaporative surfaces into cities. If green roofs are irrigated, they can contribute to urban water management and evapotranspiration can be enhanced. As part of two research projects, lysimeter measurements were used to determine the real evapotranspiration rates on the research roof of the University of Applied Sciences in Neubrandenburg, Germany. In this paper, we address the results from 2017, a humid and cool summer, and 2018, a century summer with the highest temperatures and dryness over a long period of time, measured in Northeast Germany. The lysimeter measurements varied between the normal green roof layer (variation of extensive green roof constructions) and a special construction with an extra retention layer and damming. The results show that the average daily evapotranspiration rates can be enhanced from 3 to 5 L/m2/day under optimized conditions. A second test on a real green roof with irrigation was used to explain the cooling effects of the surface above a café building in Berlin.
Approximately 10 km2 of new green roofs are built in Germany every year. About 85% of these are Extensive Green Roofs (EGR). An EGR with several research features was installed on new buildings belonging to the University of Applied Sciences Neubrandenburg in 1999. The results of the almost 20-year permanent survey of the climate effects of the green roof in contrast to gravel roofs are presented here. High-quality sensors, similar to those used by official weather stations, are in use, and data is collected every 10 s and aggregated to hourly values which enable comparisons to official measurements made by the DWD in Neubrandenburg and Berlin. The results show the typical urban heat island effect (UHI) and the mitigation effect of EGR. Whilst the temperature increased over the years due to the urban heat island effect, the temperature within the growing media in the green roof remained constant. The EGR has a stabilization effect of 1.5 K. This is good news for all those seeking a UHI mitigation solution for city centers. In a best-case scenario, the green roof potential of cities in Germany is between 3 and 8%. A value of 50% can be achieved for all buildings; roofs represent about ¼ of urban surfaces, and the cooling effect of 1.5 K in 20 years is a reasonable contribution to cooling cities and achieving environmental goals by greening urban surfaces.