Ali Mohammad Pourshahidi

Dr. Ali Mohammad Pourshahidi

Forschungszentrum Juelich GmbH
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 June 2019 in Sensors
Verified
Journal Article
Open access
PDF file
SAStefan Achtsnicht
Stefan Achtsnicht
APAli Mohammad Pourshahidi
Ali Mohammad Pourshahidi
AOAndreas Offenhäusser
Andreas Offenhäusser
Hans-Joachim KrauseHans-Joachim Krause
Hans-Joachim Krause
In modern bioanalytical methods, it is often desired to detect several targets in one sample within one measurement. Immunological methods including those that use superparamagnetic beads are an important group of techniques for these applications. The goal of this work is to investigate the feasibility of simultaneously detecting different superparamagnetic beads acting as markers using the magnetic frequency mixing technique. The frequency of the magnetic excitation field is scanned while the lower driving frequency is kept constant. Due to the particles’ nonlinear magnetization, mixing frequencies are generated. To record their amplitude and phase information, a direct digitization of the pickup-coil’s signal with subsequent Fast Fourier Transformation is performed. By synchronizing both magnetic fields, a stable phase information is gained. In this research, it is shown that the amplitude of the dominant mixing component is proportional to the amount of superparamagnetic beads inside a sample. Additionally, it is shown that the phase does not show this behaviour. Excitation frequency scans of different bead types were performed, showing different phases, without correlation to their diverse amplitudes. Two commercially available beads were selected and a determination of their amount in a mixture is performed as a demonstration for multiplex measurements.

31 August 2021 in Sensors
Verified
Journal Article
Open access
PDF file
APAli Mohammad Pourshahidi
Ali Mohammad Pourshahidi
SAStefan Achtsnicht
Stefan Achtsnicht
MNMrinal Murali Nambipareechee
Mrinal Murali Nambipareechee
AOAndreas Offenhäusser
Andreas Offenhäusser
Hans-Joachim KrauseHans-Joachim Krause
Hans-Joachim Krause
Magnetic immunoassays employing Frequency Mixing Magnetic Detection (FMMD) have recently become increasingly popular for quantitative detection of various analytes. Simultaneous analysis of a sample for two or more targets is desirable in order to reduce the sample amount, save consumables, and save time. We show that different types of magnetic beads can be distinguished according to their frequency mixing response to a two-frequency magnetic excitation at different static magnetic offset fields. We recorded the offset field dependent FMMD response of two different particle types at frequencies f1 + n⋅f2, n = 1, 2, 3, 4 with f1 = 30.8 kHz and f2 = 63 Hz. Their signals were clearly distinguishable by the locations of the extremes and zeros of their responses. Binary mixtures of the two particle types were prepared with different mixing ratios. The mixture samples were analyzed by determining the best linear combination of the two pure constituents that best resembled the measured signals of the mixtures. Using a quadratic programming algorithm, the mixing ratios could be determined with an accuracy of greater than 14%. If each particle type is functionalized with a different antibody, multiplex detection of two different analytes becomes feasible.

14 November 2022 in Sensors
Verified
Journal Article
Open access
PDF file
APAli Mohammad Pourshahidi
Ali Mohammad Pourshahidi
SAStefan Achtsnicht
Stefan Achtsnicht
AOAndreas Offenhäusser
Andreas Offenhäusser
Hans-Joachim KrauseHans-Joachim Krause
Hans-Joachim Krause
Frequency mixing magnetic detection (FMMD) has been explored for its applications in fields of magnetic biosensing, multiplex detection of magnetic nanoparticles (MNP) and the determination of core size distribution of MNP samples. Such applications rely on the application of a static offset magnetic field, which is generated traditionally with an electromagnet. Such a setup requires a current source, as well as passive or active cooling strategies, which directly sets a limitation based on the portability aspect that is desired for point of care (POC) monitoring applications. In this work, a measurement head is introduced that involves the utilization of two ring-shaped permanent magnets to generate a static offset magnetic field. A steel cylinder in the ring bores homogenizes the field. By variation of the distance between the ring magnets and of the thickness of the steel cylinder, the magnitude of the magnetic field at the sample position can be adjusted. Furthermore, the measurement setup is compared to the electromagnet offset module based on measured signals and temperature behavior.

29 June 2024 in Sensors
Verified
Journal Article
Open access
PDF file
APAli Mohammad Pourshahidi
Ali Mohammad Pourshahidi
NJNeha Susan Jean
Neha Susan Jean
CKCorinna Kaulen
Corinna Kaulen
SJSimon Jakobi
Simon Jakobi
Hans-Joachim KrauseHans-Joachim Krause
Hans-Joachim Krause
Magnetic nanoparticles (MNPs), particularly iron oxide nanoparticles (IONPs), play a pivotal role in biomedical applications ranging from magnetic resonance imaging (MRI) enhancement and cancer hyperthermia treatments to biosensing. This study focuses on the synthesis, characterization, and application of IONPs with two different size distributions for frequency mixing magnetic detection (FMMD), a technique that leverages the nonlinear magnetization properties of MNPs for sensitive biosensing. IONPs are synthesized through thermal decomposition and subsequent growth steps. Our findings highlight the critical influence of IONP size on the FMMD signal, demonstrating that larger particles contribute dominantly to the FMMD signal. This research advances our understanding of IONP behavior, underscoring the importance of size in their application in advanced diagnostic tools.

11 October 2026 in Small
Verified
Journal Article
Open access
PDF file
MAMohamad Bilal Abbas
Mohamad Bilal Abbas
MAMohamad Alaa Abbas
Mohamad Alaa Abbas
TBTimur Bikulov
Timur Bikulov
APAli Mohammad Pourshahidi
Ali Mohammad Pourshahidi
Hans-Joachim KrauseHans-Joachim Krause
Hans-Joachim Krause
Ulrich M. EngelmannUlrich M. Engelmann
Ulrich M. Engelmann
Detection of magnetic nanoparticles (MNP) relies on their nonlinear magnetic response, changing with the local environment in vivo. Employing an effective viscosity model within stochastic coupled Néel–Brownian simulations, we quantify how viscosity (0.8–50 000 mPa·s) affects signal intensity of single‐frequency magnetic particle spectroscopy (MPS, 25 kHz) and frequency‐mixing MPS (FM‐MPS; f H = 40.5 kHz, f L = 0.063 kHz). We investigate single‐core, non‐interacting MNP with various core sizes (12–28 nm), hydrodynamic shell thicknesses (5–100 nm), and anisotropy (4–200 kJ m − 3 ), using dominant readouts (MPS: third‐harmonic; FM‐MPS: f H + 2 f L mixing‐term). Increasing viscosity progressively suppresses Brownian rotation, with thicker shells affected at lower viscosities, and drives signals toward an immobilization plateau. Under the simulated conditions, MNP appear distinguishable in blood‐associated viscosities using MPS, whereas distinguishability is pronounced in cellular/tissue‐like viscosities with FM‐MPS. Moderate anisotropy (∼20–40 kJ m − 3 ) enhances signals by ∼10%, whereas higher anisotropies suppress relaxation, finally collapsing the signal. While large cores maximize the signal at fixed particle number, dosage‐normalized conditions suggest favorable performance for intermediate cores (∼15–18 nm). These results propose a cohesive framework linking particle properties, excitation scheme, and physiological environment, thereby providing insight into MNP tracer optimization for biosensing, cell tracking, imaging, and in vivo diagnostics.