Jared Oremo

Mr. Jared Oremo


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 June 2018 in BMC Public Health
Verified
Journal Article
Open access
PDF file
KCKathryn G. Curran
Kathryn G. Curran
EWEmma Wells
Emma Wells
SCSamuel J. Crowe
Samuel J. Crowe
RNRupa Narra
Rupa Narra
JOJared Oremo
Jared Oremo
JKJackson Kioko
Jackson Kioko
From December 2014 to September 2016, a cholera outbreak in Kenya, the largest since 2010, caused 16,840 reported cases and 256 deaths. The outbreak affected 30 of Kenya’s 47 counties and occurred shortly after the decentralization of many healthcare services to the county level. This mixed-methods study, conducted June–July 2015, assessed cholera preparedness in Homa Bay, Nairobi, and Mombasa counties and explored clinic- and community-based health care workers’ (HCW) experiences during outbreak response. Counties were selected based on cumulative cholera burden and geographic characteristics. We conducted 44 health facility cholera preparedness checklists (according to national guidelines) and 8 focus group discussions (FGDs). Frequencies from preparedness checklists were generated. To determine key themes from FGDs, inductive and deductive codes were applied; MAX software for qualitative data analysis (MAXQDA) was used to identify patterns. Some facilities lacked key materials for treating cholera patients, diagnosing cases, and maintaining infection control. Overall, 82% (36/44) of health facilities had oral rehydration salts, 65% (28/43) had IV fluids, 27% (12/44) had rectal swabs, 11% (5/44) had Cary-Blair transport media, and 86% (38/44) had gloves. A considerable number of facilities lacked disease reporting forms (34%, 14/41) and cholera treatment guidelines (37%, 16/43). In FDGs, HCWs described confusion regarding roles and reporting during the outbreak, which highlighted issues in coordination and management structures within the health system. Similar to checklist findings, FGD participants described supply challenges affecting laboratory preparedness and infection prevention and control. Perceived successes included community engagement, health education, strong collaboration between clinic and community HCWs, and HCWs’ personal passion to help others. The confusion over roles, reporting, and management found in this evaluation highlights a need to adapt, implement, and communicate health strategies at the county level, in order to inform and train HCWs during health system transformations. International, national, and county stakeholders could strengthen preparedness and response for cholera and other public health emergencies in Kenya, and thereby strengthen global health security, through further investment in the existing Integrated Disease Surveillance and Response structure and national cholera prevention and control plan, and the adoption of county-specific cholera control plans.

SDSamuel Dorevitch
Samuel Dorevitch
KAKendall Anderson
Kendall Anderson
ASAbhilasha Shrestha
Abhilasha Shrestha
DFDorothy Wright Foulkes
Dorothy Wright Foulkes
AOAloyce Odhiambo
Aloyce Odhiambo
IHIra Heimler
Ira Heimler
Ozonation is widely used in high-income countries for water disinfection in centralized treatment facilities. New microplasma technology has reduced the energy requirements for ozone generation dramatically, such that a 15-watt solar panel is sufficient to produce small quantities of ozone. This technology has not been used previously for point-of-use drinking water treatment. We conducted a series of assessments of this technology, both in the laboratory and in homes of residents of a village in western Kenya, to estimate system efficacy and to determine if the solar-powered point-of-use water ozonation system appears safe and acceptable to end-users. In the laboratory, two hours of point-of-use ozonation reduced E. coli in 120 L of wastewater by a mean (standard deviation) of 2.3 (0.84) log-orders of magnitude and F+ coliphage by 1.54 (0.72). Based on laboratory efficacy, 10 families in Western Kenya used the system to treat 20 L of household stored water for two hours on a daily basis for eight weeks. Household stored water E. coli concentrations of >1000 most probable number (MPN)/100 mL were reduced by 1.56 (0.96) log removal value (LRV). No participants experienced symptoms of respiratory or mucous membrane irritation. Focus group research indicated that families who used the system for eight weeks had very favorable perceptions of the system, in part because it allowed them to charge mobile phones. Drinking water ozonation using microplasma technology may be a sustainable point-of-use treatment method, although system optimization and evaluations in other settings would be needed.

4 September 2019 in The American Journal of Tropical Medicine and Hygiene
Verified
Journal Article
Closed access
WDWilliam Davis
William Davis
AOAloyce Odhiambo
Aloyce Odhiambo
JOJared Oremo
Jared Oremo
RORonald Otieno
Ronald Otieno
AMAlex Mwaki
Alex Mwaki
RQRobert Quick
Robert Quick
To address water and hygiene infrastructure deficiencies in health-care facilities (HCFs) in Siaya County, Kenya, portable water stations, soap, and water treatment products were provided to 109 HCFs in 2005. In 2011 and again in 2016, we interviewed staff in 26 randomly selected HCFs, observed water sources, water stations, and tested source and stored water for chlorine residual and Escherichia coli. Of 26 HCFs, 22 (85%) had improved water supplies, and 22 (85%) had functioning handwashing and drinking water stations, but < 50% provided soap or water treatment. Thirteen (50%) of 26 source water samples yielded E. coli; 24 (92%) of 26 stored water samples yielded no E. coli, including nine with residual chlorine and nine untreated samples from sources yielding no E. coli. Eleven years after implementation, 85% of HCFs continued to use water stations that protected water from recontamination. Sustainable provision of soap and water treatment products could optimize intervention use.

27 May 2019 in Water
Verified
Journal Article
Open access
PDF file
RMRegula Meierhofer
Regula Meierhofer
PRPascal Rubli
Pascal Rubli
JOJared Oremo
Jared Oremo
AOAlloyce Odhiambo
Alloyce Odhiambo
Efforts to provide safe water are challenged by recontamination and regrowth of pathogens in treated water during storage. This study evaluated the potential of metallic silver with a chemically etched surface to reduce recontamination risks during water storage in ceramic water filters. Batch experiments were conducted in the laboratory with water storage buckets containing three configurations of varying amounts of silver. Field trials in a rural area in Kenya assessed the effect of the same configurations in the storage buckets of locally produced ceramic pot filters without colloidal silver coating. The tests revealed that the etched silver slightly reduced microbiological recontamination risks during water storage despite the low diffusion of silver ions (<5 µg Ag/L). The effect was strongly influenced by water chemistry parameters. A statistically significant difference in the removal of E. coli (Δ Log Removal Value (LRV) = 0.6) and total coliforms (Δ LRV = 1.7) was found between households using a filter with silver in the water reservoir and those using a filter without silver. Multivariate regression of water handling factors and hygiene practices on filter performance revealed that the presence of silver in the reservoir and cleaning the filter element with a brush were associated with a better filter performance.

1 July 2020 in The American Journal of Tropical Medicine and Hygiene
Verified
Journal Article
Closed access
KFKirsten Fagerli
Kirsten Fagerli
LGLaura Gieraltowski
Laura Gieraltowski
BNBenjamin Nygren
Benjamin Nygren
EFEric Foote
Eric Foote
JGJoanna Gaines
Joanna Gaines
RQRobert Quick
Robert Quick
Diarrheal illness remains a leading cause of morbidity and mortality in children < 5 years in developing countries, and contaminated water contributes to diarrhea risk. To address this problem, a novel hollow fiber ultrafilter (HFU) was developed for household water treatment. To test its impact on water quality and infant health, we conducted a cluster-randomized longitudinal evaluation in 10 intervention and 10 comparison villages in Kenya, attempting to enroll all households with infants (< 12 months old). We conducted a baseline survey, distributed HFUs to intervention households, made biweekly home visits for 1 year to assess water treatment practices and diarrhea in infants, and tested water samples from both groups every 2 months for Escherichia colt. We enrolled 92 infants from intervention households and 74 from comparison households. During the 1-year study period, 45.7% of intervention households and 97.3% of comparison households had at least one stored water sample test positive for E. coli Compared with comparison households, the odds of E. coli contamination in stored water was lower for intervention households (odds ratio [OR]: 0.42, 95% CI: 0.24, 0.74), but there was no difference in the odds of reported diarrhea in infants, adjusting for covariates (OR: 1.19, 95% CI: 0.74, 1.90). Although nearly all water samples obtained from unprotected sources and filtered by the HFU were free of E. coli contamination, HFUs alone were not effective at reducing diarrhea in infants.