Taddäus Schaffers

Dr. Taddäus Schaffers


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2017 in Review of Scientific Instruments
Verified
Journal Article
Closed access
TSTaddäus Schaffers
Taddäus Schaffers
RMR. Meckenstock
R. Meckenstock
DSD. Spoddig
D. Spoddig
TFThomas Feggeler
Thomas Feggeler
KOK. Ollefs
K. Ollefs
ANAndreas Ney
Andreas Ney
We present two new and complementary approaches to realize spatial resolution for ferromagnetic resonance (FMR) on the 100 nm-scale. Both experimental setups utilize lithographically fabricated micro-resonators. They offer a detection sensitivity that is increased by four orders of magnitude compared with resonator-based FMR. In the first setup, the magnetic properties are thermally modulated via the thermal near-field effect generated by the thermal probe of an atomic force microscope. In combination with lock-in detection of the absorbed microwave power in the micro-resonator, a spatial resolution of less than 100 nm is achieved. The second setup is a combination of a micro-resonator with a scanning transmission x-ray microscope (STXM). Here a conventional FMR is excited by the micro-resonator while focused x-rays are used for a time-resolved snap-shot detection of the FMR excitations via the x-ray magnetic circular dichroism effect. This technique allows a lateral resolution of nominally 35 nm given by the STXM. Both experimental setups combine the advantage of low-power FMR excitation in the linear regime with high spatial resolution to study single and coupled nanomagnets. As proof-of-principle experiments, two perpendicular magnetic micro-stripes (5 μ m × 1 μ m) were grown and their FMR excitations were investigated using both setups.

28 June 2019 in Nanomaterials
Verified
Journal Article
Open access
PDF file
TSTaddäus Schaffers
Taddäus Schaffers
TFThomas Feggeler
Thomas Feggeler
SPSanta Pile
Santa Pile
RMRalf Meckenstock
Ralf Meckenstock
MBMartin Buchner
Martin Buchner
ANAndreas Ney
Andreas Ney
Using a time-resolved detection scheme in scanning transmission X-ray microscopy (STXM), we measured element resolved ferromagnetic resonance (FMR) at microwave frequencies up to 10 GHz and a spatial resolution down to 20 nm at two different synchrotrons. We present different methods to separate the contribution of the background from the dynamic magnetic contrast based on the X-ray magnetic circular dichroism (XMCD) effect. The relative phase between the GHz microwave excitation and the X-ray pulses generated by the synchrotron, as well as the opening angle of the precession at FMR can be quantified. A detailed analysis for homogeneous and inhomogeneous magnetic excitations demonstrates that the dynamic contrast indeed behaves as the usual XMCD effect. The dynamic magnetic contrast in time-resolved STXM has the potential be a powerful tool to study the linear and nonlinear, magnetic excitations in magnetic micro- and nano-structures with unique spatial-temporal resolution in combination with element selectivity.

18 February 2020 in Applied Physics Letters
Verified
Journal Article
Open access
PDF file
SPSanta Pile
Santa Pile
TFThomas Feggeler
Thomas Feggeler
TSTaddäus Schaffers
Taddäus Schaffers
RMR. Meckenstock
R. Meckenstock
MBM. Buchner
M. Buchner
KOK. Ollefs
K. Ollefs
A non-standing characteristic of directly imaged spin-waves in confined micrometer-sized ultrathin Permalloy ( Ni 80 Fe 20 ) structures is reported along with evidence of the possibility to alter the observed state by modifications to the sample geometry. Using micromagnetic simulations, the presence of the spin-wave modes excited in the Permalloy stripes along with the quasi-uniform modes was observed. The predicted spin-waves were imaged in direct space using time resolved scanning transmission x-ray microscopy, combined with a ferromagnetic resonance excitation scheme (STXM-FMR). STXM-FMR measurements revealed a non-standing characteristic of the spin-waves. Also, it was shown by micromagnetic simulations and confirmed using STXM-FMR results that the observed characteristic of the spin-waves can be influenced by the local magnetic fields in different sample geometries.

1 September 2020 in Physical Review Applied
Verified
Journal Article
Open access
PDF file
SPSanta Pile
Santa Pile
MBM. Buchner
M. Buchner
VNV. Ney
V. Ney
TSTaddäus Schaffers
Taddäus Schaffers
JLJ. Lumetzberger
J. Lumetzberger
ANAndreas Ney
Andreas Ney
Spin pumping in a ferromagnet-nonferromagnet heterostructure is directly imaged with spatial resolution as well as element selectivity. The time-resolved detection in scanning transmission x-ray microscopy allows us to directly probe the spatial extent of the ac spin polarization in Co-doped ZnO, which is generated by spin pumping from an adjacent permalloy microstrip. Comparing the relative phases of the dynamic magnetization component of the two constituents is possible and found to be close to antiphase. The correlation between the distribution of the magnetic excitation in the permalloy and the Co-doped ZnO reveals that laterally there is no one-to-one correlation. The observed distribution is rather complex, but integrating over larger areas demonstrates that the spin polarization in the nonferromagnet extends laterally beyond the region of the ferromagnetic microstrip. Therefore, the observations are better explained by a local spin pumping efficiency and a lateral propagation of the ac spin polarization in the nonferromagnet over the range of a few micrometers.

22 January 2020 in Journal of Applied Physics
Verified
Journal Article
Open access
PDF file
MBMartin Buchner
Martin Buchner
JLJulia Lumetzberger
Julia Lumetzberger
VNVerena Ney
Verena Ney
TSTaddäus Schaffers
Taddäus Schaffers
NDNiéli Daffé
Niéli Daffé
ANAndreas Ney
Andreas Ney
Heterostructures of Co-doped ZnO and Permalloy were investigated for their static and dynamic magnetic interactions. The highly Co-doped ZnO is paramagnetic at room temperature and becomes an uncompensated antiferromagnet at low temperatures, showing a narrowly opened hysteresis and a vertical exchange-bias shift even in the absence of any ferromagnetic layer. At low temperatures in combination with Permalloy, an exchange bias is found causing a horizontal as well as a vertical shift of the hysteresis of the heterostructure together with an increase in coercive field. Furthermore, an increase in the Gilbert damping parameter at room temperature was found by multifrequency ferromagnetic resonance (FMR), indicating spin pumping. Temperature dependent FMR shows a maximum in magnetic damping close to the magnetic phase transition. These measurements also evidence the exchange-bias interaction of Permalloy and long-range ordered Co–O–Co structures in ZnO, which are barely detectable by SQUID due to the shorter probing times in FMR.

12 December 2022 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
RMRhodri Mansell
Rhodri Mansell
TSTaddäus Schaffers
Taddäus Schaffers
RHRasmus B. Holländer
Rasmus B. Holländer
HQHuajun Qin
Huajun Qin
SDSebastiaan van Dijken
Sebastiaan van Dijken
Active control of propagating short-wavelength spin waves in perpendicularly magnetized materials is promising for designing nanoscale magnonic devices. One method of manipulating spin waves on the nanoscale is through their interaction with magnetic textures, an example of which is the magnetic skyrmion—a particle-like topological object stabilized in thin film heterostructures by the Dzyaloshinskii–Moriya interaction (DMI) and perpendicular magnetic anisotropy. In this paper, the interaction between spin waves and skyrmions is studied using micromagnetic simulations. The magnetic parameters chosen are similar to those found experimentally, leading to a skyrmion with an extended core of reversed magnetization. The effect of a propagating spin wave on the skyrmion is to cause the emission of a secondary spin wave by the skyrmion. At low frequencies, where the incoming spin wave wavelength is much larger than the skyrmion, this leads to a nearly circular re-emitted spin wave. The pattern of emission becomes increasingly complex at higher frequencies as the wavelength becomes similar to the skyrmion size due to the complex excitation of the extended core. The emitted spin wave profile can be controlled by altering the size of the skyrmion through the magnitude of the DMI, providing a method of tuning the system.