Cecilia Villalaín

Cecilia Villalaín

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 November 2018 in Ultrasound in Obstetrics & Gynecology
Verified
Journal Article
Closed access
PDF file
IHIgnacio Herraiz
Ignacio Herraiz
MQM. S. Quezada
M. S. Quezada
JRJ. Rodriguez‐Calvo
J. Rodriguez‐Calvo
EGE. Gómez‐Montes
E. Gómez‐Montes
CVCecilia Villalaín
Cecilia Villalaín
AGA. Galindo
A. Galindo

1 October 2020 in Ultrasound in Obstetrics & Gynecology
Verified
Journal Article
Closed access
MQM. S. Quezada
M. S. Quezada
JRJ. Rodríguez‐Calvo
J. Rodríguez‐Calvo
CVCecilia Villalaín
Cecilia Villalaín
PGP. I. Gómez‐Arriaga
P. I. Gómez‐Arriaga
AGA. Galindo
A. Galindo
IHIgnacio Herraiz
Ignacio Herraiz

11 March 2022 in Journal of Perinatal Medicine
Verified
Journal Article
Closed access
Themistoklis DagklisThemistoklis Dagklis
Themistoklis Dagklis
CSCihat Sen
Cihat Sen
Ioannis TsakiridisIoannis Tsakiridis
Ioannis Tsakiridis
CVCecilia Villalaín
Cecilia Villalaín
Karel AllegaertKarel Allegaert
Karel Allegaert
MSMilan Stanojevic
Milan Stanojevic
This practice guideline follows the mission of the World Association of Perinatal Medicine in collaboration with the Perinatal Medicine Foundation, bringing together groups and individuals throughout the world, with the goal of improving the use of antenatal corticosteroids (ACS) for fetal maturation. In fact, this document provides further guidance for healthcare practitioners on the appropriate use of ACS with the aim to increase the timely administration and avoid unnecessary or excessive use. Therefore, it is not intended to establish a legal standard of care. This document is based on consensus among perinatal experts throughout the world and serves as a guideline for use in clinical practice.

9 March 2024 in Ultrasound in Obstetrics & Gynecology
Verified
Journal Article
Open access
CVCecilia Villalaín
Cecilia Villalaín
FDFrancesco D'Antonio
Francesco D'Antonio
MFM. E. Flacco
M. E. Flacco
EGE. Gómez‐Montes
E. Gómez‐Montes
IHIgnacio Herraiz
Ignacio Herraiz
AGA. Galindo
A. Galindo
Objective: To determine the diagnostic accuracy of prenatal ultrasound in detecting coarctation of the aorta (CoA).Methods: An individual participant data meta‐analysis was performed to report on the strength of association and diagnostic accuracy of different ultrasound signs in detecting CoA prenatally. MEDLINE, EMBASE and CINAHL were searched for studies published between January 2000 and November 2021. Inclusion criteria were fetuses with suspected isolated CoA, defined as ventricular and/or great vessel disproportion with right dominance on ultrasound assessment. Individual participant‐level data were obtained by two leading teams. PRISMA‐IPD and PRISMA‐DTA guidelines were used for extracting data, and the QUADAS‐2 tool was used for assessing quality and applicability. The reference standard was CoA, defined as narrowing of the aortic arch, diagnosed after birth. The most commonly evaluated parameters on ultrasound, both in B‐mode and on Doppler, constituted the index test. Summary estimates of sensitivity, specificity, diagnostic odds ratio (DOR) and likelihood ratios were computed using the hierarchical summary receiver‐operating‐characteristics model.Results: The initial search yielded 72 studies, of which 25 met the inclusion criteria. Seventeen studies (640 fetuses) were included. On random‐effects logistic regression analysis, tricuspid valve/mitral valve diameter ratio > 1.4 and > 1.6, aortic isthmus/arterial duct diameter ratio < 0.7, hypoplastic aortic arch (all P < 0.001), aortic isthmus diameter Z‐score of < −2 in the sagittal (P = 0.003) and three‐vessel‐and‐trachea (P < 0.001) views, pulmonary artery/ascending aorta diameter ratio > 1.4 (P = 0.048) and bidirectional flow at the foramen ovale (P = 0.012) were independently associated with CoA. Redundant foramen ovale was inversely associated with CoA (P = 0.037). Regarding diagnostic accuracy, tricuspid valve/mitral valve diameter ratio > 1.4 had a sensitivity of 72.6% (95% CI, 48.2–88.3%), specificity of 65.4% (95% CI, 46.9–80.2%) and DOR of 5.02 (95% CI, 1.82–13.9). The sensitivity and specificity values were, respectively, 75.0% (95% CI, 61.1–86.0%) and 39.7% (95% CI, 27.0–53.4%) for pulmonary artery/ascending aorta diameter ratio > 1.4, 47.8% (95% CI, 14.6–83.0%) and 87.6% (95% CI, 27.3–99.3%) for aortic isthmus diameter Z‐score of < –2 in the sagittal view and 74.1% (95% CI, 58.0–85.6%) and 62.0% (95% CI, 41.6–78.9%) for aortic isthmus diameter Z‐score of < –2 in the three‐vessel‐and‐trachea view. Hypoplastic aortic arch had a sensitivity of 70.0% (95% CI, 42.0–88.6%), specificity of 91.3% (95% CI, 78.6–96.8%) and DOR of 24.9 (95% CI, 6.18–100). The diagnostic yield of prenatal ultrasound in detecting CoA did not change significantly when considering multiple categorical parameters. Five of the 11 evaluated continuous parameters were independently associated with CoA (all P < 0.001) but all had low‐to‐moderate diagnostic yield.Conclusions: Several prenatal ultrasound parameters are associated with an increased risk for postnatal CoA. However, diagnostic accuracy is only moderate, even when combinations of parameters are considered. © 2024 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

30 November 2020 in PLOS ONE
Verified
Journal Article
Open access
PDF file
CVCecilia Villalaín
Cecilia Villalaín
IHIgnacio Herraiz
Ignacio Herraiz
JLJoanna Luczkowiak
Joanna Luczkowiak
APAlfredo Pérez-Rivilla
Alfredo Pérez-Rivilla
MFMaría Dolores Folgueira
María Dolores Folgueira
RDRafael Delgado
Rafael Delgado
Objectives: To evaluate the progression of the seroprevalence of SARS-CoV-2 in the pregnant population of the south of Madrid during the first wave of the COVID-19 pandemic. Secondarily we aimed to evaluate maternal and perinatal outcomes. Study design: Retrospective cohort study conducted at Hospital Universitario 12 de Octubre during weeks 10 to 19 of 2020, coinciding with the Spanish lockdown. We tested 769 serum samples obtained from routine serological testing during the first and third trimesters of pregnancy for specific IgG anti SARS-CoV-2 RBD and S proteins. RT-PCR tests were performed in suspected cases according to clinical practice. We compared maternal and perinatal outcomes in those with delivered pregnancies (n = 578) according to the presence or absence of specific IgG antibodies. Those with positive IgG were subdivided by the presence or absence of Covid-19 related symptoms at any time and the results of RT-PCR testing if performed. Therefore, we had 4 study groups: G1 (IgG negative), G2 (IgG positive, asymptomatic, RT-PCR testing negative or not done), G3 (IgG positive, symptomatic, RT-PCR testing negative or not done), and G4 (IgG positive, symptomatic, RT-PCR positive). Results: Seropositivity increased from 0% to 21.4% (95% CI 11.8–31.0) during the study period, of which 27.9% had an asymptomatic course. Overall outcomes were favorable with a significant increased rate of preterm birth in G4 vs G1 (21.4% vs 6.7%) and cesarean/operative delivery (50% vs 26.9%). Asymptomatic and mild cases did not have differences regarding pregnancy course when compared to seronegative women. There were no documented cases of vertical or horizontal transmission. Conclusion: Seroprevalence in pregnant women in southern Madrid went up to 21.4% of which 27.9% had an asymptomatic course. Overall perinatal results were favorable, especially in those asymptomatic.

9 April 2020 in Journal of the American Heart Association
Verified
Journal Article
Open access
PDF file
CVCecilia Villalaín
Cecilia Villalaín
IHIgnacio Herraiz
Ignacio Herraiz
LVLeonor Valle
Leonor Valle
MMManel Mendoza
Manel Mendoza
JDJuan Luis Delgado
Juan Luis Delgado
AGAlberto Galindo
Alberto Galindo
Background: There is little knowledge about the significance of extremely high values (>655) for the ratio of sF lt‐1 (soluble fms‐like tyrosine kinase 1) to Pl GF (placental growth factor). We aim to describe the time‐to‐delivery interval and maternal and perinatal outcomes when such values are demonstrated while assessing suspected or confirmed placental dysfunction based on clinical or sonographic criteria. Methods and Results: A multicenter retrospective cohort study was performed on 237 singleton gestations between 20+0 and 37+0 weeks included at the time of first demonstrating a sF lt‐1/Pl GF ratio >655. Clinicians were aware of this result, but standard protocols were followed for delivery indication. Main outcomes were compared for women with and without preeclampsia at inclusion. In those with preeclampsia (n=185, of whom 77.3% had fetal growth restriction), severe preeclampsia features and fetal growth restriction in stages III or IV were present in 49.2% and 13.5% cases, respectively, at inclusion and in 77.3% and 28.6% cases, respectively, at delivery. In the group without preeclampsia (n=52, 82.7% had fetal growth restriction), these figures were 0% and 30.8%, respectively, at inclusion and 21.2% and 50%, respectively, at delivery. Interestingly, 28% of women without initial preeclampsia developed it later. The median time to delivery was 4 days (interquartile range: 1–6 days) and 7 days (interquartile range: 3–12 days), respectively ( P <0.01). Overall, perinatal mortality was 62.1% before 24 weeks; severe morbidity surpassed 50% before 29 weeks but became absent from 34 weeks. Maternal serious morbidity was high at any gestational age. Conclusions: An sF lt‐1/Pl GF ratio >655 is almost invariably associated with preeclampsia or fetal growth restriction that progresses rapidly. In our tertiary care settings, we observed that maternal adverse outcomes were high throughout gestation, whereas perinatal adverse outcomes diminished as pregnancy advanced.