Red clay slopes have different failure modes in different geological and climatic contexts. Underlying weak layers are frequently witnessed in integral failures because of the reverse consolidation characteristics. On the contrary, heavy rainfall often causes superficial sliding for a considerable infiltration through developed microfractures. Based on the Geographic Information System, regional stability of red clay slopes was evaluated with two failure modes, such as “integral sliding” and “planar sliding.” First, terrain and borehole data of the study area were used to construct the digital elevation model. Second, slope units were partitioned as research objects. For integral sliding, the slip surface was supposed to lie above the strata interface, and it was regarded as a lower part of an ellipsoid. After calculating safety factors of potential slip surfaces that were randomly generated by the Monte Carlo method, the minimum safety factor of the slope unit and the critical slip surface could be determined. For shallow landslides triggered by rainfall infiltration, the one‐dimensional infiltration model and infinite slope model were used. Moreover, the difference between the sliding direction of each column and the main aspect of entire slope unit was considered in safety factor calculation. Finally, regional slope stability characterized by the safety factor would be available; thus, it would be beneficial to sliding prevention and disaster treatment in this region.
8 September 2012 in Journal of Central South University
Assuming slope failures of weathered soil to be shallow sliding under heavy rainfall, an infinite slope model for slope stability analysis is proposed, in which the infiltration depth is explicitly expressed by time and the seepage force is taken into account. Comparative study on the influence of parameters is conducted, which shows that matric suction plays an insignificant role in slope stability while comparing to the slope angle and infiltration depth.
In order to investigate the pullout resistance of the Horizontal-Vertical reinforcement, a “denti-geogrid” was assembled by bonding a “denti-strip” with the geogrid and the pullout tests were carried out. Subsequently, the analytical approaches were investigated to calculate the pullout resistance on the basis of the surface sliding model, Perterson and Anderson’s model, Jewell’s model, Chai’s model, and the proposed stress summation model. Moreover, a new index named “scale factor” was suggested to reflect the proportion of bearing resistance provided by transversal members. The research showed that: 1) under the same test conditions, the pullout resistance of denti-geogrid was much higher than that of a common geogrid. All common geogrids showed linear strain softening in the later stage of pullout tests. Given the same normal stresses, due to the expansion of effective areas suffering lateral earth pressure, more denti-strips meant more significant resistance; 2) Among five theoretical approaches, the solutions of the proposed stress summation model made the best agreement with lab test results, with an average relative error of 2.82%. On the other hand, the stress summation model also showed a simplicity in calculation; and 3) Due to higher gradient of the fitting curve of scale factors under lower load, the bearing resistance would be more and more dominant, which means that the lateral resistance of denti-strips could play a decisive role in cases of low stress level.
1 June 2018 in Journal of Highway and Transportation Research and Development (English Edition)
To explore the working mechanism of retaining a wall reinforced with denti-geogrids, the numerical simulation of a pullout test was performed, the working behavior and influencing factors were analyzed, a generalized model was suggested, and an ultimate pullout force calculation formula was proposed. The research obtains the following results. (1) The horizontal displacement of the inner segment of the geogrid is relatively small because of the denti-strips. (2) The displacement gradients of the denti-geogrid are evidently large, whereas the horizontal displacement core is approximately 25 cm outside the denti-strip. The peak value of the horizontal displacement is approximately 3 cm. (3) The pullout force peaks when the denti-strip is approximately 3 m from the lateral boundary. The effective span is extended, and the resistance of the denti-strip increases with denti-strip spacing. Denti-strip height is positively correlated with the pullout force, whereas the influence of thickness is insignificant. (4) The working mechanism of denti-geogrid can be roughly described by three processes, namely, compaction, detour flow, and convergence. (5) The calculation values of the ultimate pullout force obtained from the generalized model are close to the numerical test results. Thus, the applicability of the suggested model was verified.
The semispatial static allowable stress field was constructed by three‐dimensional stress columns, and the analytical lower‐bound solution of bearing capacity of Mohr–Coulomb foundation beneath circular uniformly distributed load was put forward for the first time. The influence of the amount of stress columns and soil shear strength parameters on the lower‐bound solution of the foundation‐bearing capacity is analyzed. The research showed that (1) when the number of stress columns is more than 9 (n > 4) and the friction angle is less than 30°, the relative error between the lower‐bound solution of the bearing capacity and exact solution is less than 6.6%, (2) the suggested analytical solution is applicable for common clayey materials; thus, the application scope of the analytical lower‐bound solution is further expanded, and (3) the influence of cohesion on bearing capacity is linear. However, with the increase of the friction angle, the bearing capacity increases faster and faster under all cohesion levels. The correctness and effectiveness of the proposed method were verified by literature comparison.