Piercarlo Romagnoni

Prof. Piercarlo Romagnoni

Università Iuav di Venezia, Venice, Veneto, Italy
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2018 in Energy and Buildings
Verified
Journal Article
Closed access
TMTiziano Dalla Mora
Tiziano Dalla Mora
FPF. Peron
F. Peron
PRPiercarlo Romagnoni
Piercarlo Romagnoni
Manuela AlmeidaManuela Almeida
Manuela Almeida
MFM. Ferreira
M. Ferreira

1 May 2019 in Sustainable Cities and Society
Verified
Journal Article
Closed access
LPLorenza Pistore
Lorenza Pistore
GPGiovanni Pernigotto
Giovanni Pernigotto
Francesca CappellettiFrancesca Cappelletti
Francesca Cappelletti
AGAndrea Gasparella
Andrea Gasparella
PRPiercarlo Romagnoni
Piercarlo Romagnoni

26 March 2018 in Sustainability
Verified
Journal Article
Open access
PDF file
TMTiziano Dalla Mora
Tiziano Dalla Mora
MPMaria Pinamonti
Maria Pinamonti
LTLorenzo Teso
Lorenzo Teso
GBGiosuè Boscato
Giosuè Boscato
FPFabio Peron
Fabio Peron
PRPiercarlo Romagnoni
Piercarlo Romagnoni
The main part of Italian building stock was built before the energy and seismic regulations, so most of buildings need comprehensive refurbishment to achieve the performance required by laws that are in force. This paper presents an experimental study for an energy and structural upgrade methodology, applied to an existing school building in the north-east of Italy. The methodology is based on the International Energy Agency–Energy in Buildings and Communities Programme (IEA–EBC) Annex 56 project guidelines. For the energy retrofit, a set of interventions is defined concerning the building envelope and systems. Among these interventions, the optimal cost is identified: this minimizes the energy demand and the CO2 emissions, and reduces the financial commitment. The analysis of the seismic retrofit is developed using innovative techniques of intervention and high-performance materials. The proposed interventions are evaluated in terms of efficacy and cost. The results show that it is possible to identify a comprehensive energy retrofit at optimal cost, thanks to high energy saving and subsidies. For the seismic retrofit, the intervention with the higher cost-effectiveness ratio is determined, but the related investment does not have a payback time. The union of the two retrofits permits the combination of benefits and has a payback time for both the interventions. It is possible to state that the cost of a combined intervention is lower than the costs of two different interventions; therefore, when a single retrofit is needed, the possibility of a combined intervention should be evaluated.

17 October 2019 in Energies
Verified
Journal Article
Open access
PDF file
EMElena Mazzola
Elena Mazzola
TMTiziano Dalla Mora
Tiziano Dalla Mora
FPFabio Peron
Fabio Peron
PRPiercarlo Romagnoni
Piercarlo Romagnoni
The valorization and sustainable management of historic centers is a topic relevant to the cultural identity and heritage of European cities. A rational strategy to preserve the centers must consider both energy and environmental retrofitting, even if this is a complex issue requiring interdisciplinary approaches, dedicated diagnostic procedures, and specific tools. Within this context, this paper proposes an integrated method for energy and environmental analysis specifically devoted to historical building retrofit. Attention is focused on cases in which building management is not interested in renovation or in a deep conservation project, but instead in green management and maintenance overhaul. The basis of the procedure is the Leadership in Energy and Environmental Design for Existing Buildings: Operations and Maintenance (LEED O+M) rating protocol. The global goal was the definition of an intervention strategy indicating the principal direction of action. The first step is identifying critical issues in the operation of the building through energy diagnosis and dynamic thermophysical simulations. The second step is defining a panel of appropriate retrofit measures. The third step is choosing between alternatives to increase the sustainability performance following an environmental assessment scheme. Ca’ Rezzonico in Venice (Italy), a 17th-century palace, nowadays the seat of a museum, was used as a case study to apply the proposed methodology.

20 August 2021 in Energies
Verified
Journal Article
Open access
PDF file
TMTiziano Dalla Mora
Tiziano Dalla Mora
LTLorenzo Teso
Lorenzo Teso
LCLaura Carnieletto
Laura Carnieletto
Angelo ZarrellaAngelo Zarrella
Angelo Zarrella
PRPiercarlo Romagnoni
Piercarlo Romagnoni
The residential building stock represents one of the major players in energy use and greenhouse gas emissions; thus, it is fundamental to reduce the energy used. Simulation tools are becoming more and more accurate in compliance with the new requirements both at the single-building and at the district scale, although they are not affordable by non-specialist users such as policymakers. The research concerns the evaluation of the energy demand for space heating for a historical district that is representative of the Italian building stock. The work compares dynamic and specialist-oriented urban scale tools such as Energy Urban Resistance Capacitance Approach (EUReCA) and City Energy Analyst (CEA)) as well as a quasi-steady-state calculation method (Excel spreadsheet), which is more affordable for non-specialist users. The work was carried out to assess the possible deviation of the results between the dynamic and quasi-steady-state calculation methods, as well as to identify any limits and opportunities in the application of the latter procedure, which is currently the official national calculation tool for the implementation of Directive 2010/31/EU. The study shows how the quasi-steady-state method predicts a reliable building energy demand, in line with the results obtained by the two dynamic tools, when considering only geometry and infiltrations as input. However, the limits of the quasi-steady-state method emerge when introducing internal loads, significantly underestimating the energy demand compared to CEA and EUReCA simulations. The results underline the potential application of the quasi-steady-state method to predict energy demand, although dynamics tools are more reliable but far more complex. Major findings through two methods concern the impact of solar heat gains on the overall heating demand at both the single building and the district scale. The different results between the tools provided evidence of a gap in the use of the simplest tool and demonstrated the accuracy and reliability of the proposed approach with a lower computational effort.

11 September 2019 in Science and Technology for the Built Environment
Verified
Journal Article
Closed access
LPLorenza Pistore
Lorenza Pistore
IPIlaria Pittana
Ilaria Pittana
Francesca CappellettiFrancesca Cappelletti
Francesca Cappelletti
PRPiercarlo Romagnoni
Piercarlo Romagnoni
AGAndrea Gasparella
Andrea Gasparella
This article presents a method to conduct non-invasive subjective surveys applied to the evaluation of the indoor environmental conditions of a secondary school building by means of students’ subjective responses. The case study is a secondary school in Treviso (Italy). Field campaigns have been carried out three times during the heating season 2016-2017 in seven among thirty classrooms, in order to conduct the evaluation in representative conditions limiting the interference with teachers’ and students’ activities. Students were asked to assess their overall satisfaction about the environment, their behavior towards discomfort and their interactions with the building and the systems. A specific questionnaire has been developed paying particular attention to the occupants’ target and to the questions intended to grasp not only the comfort feedbacks, but also the interactions and the individual students’ attitudes that can influence the building energy performance. The students’ satisfaction has been analyzed for all the comfort areas (i.e., thermal, visual, acoustic and air quality) applying the method proposed by the technical standard EN 15251 for thermal comfort and extending it to all the other comfort aspects. Then, statistical tests have been implemented in order to investigate the significance of the date chosen for administering the surveys, the classrooms’ location inside the building (e.g., orientation and level) and the heating system with the thermal satisfaction and sensation. Subjective responses have also been used to understand the perceived causes of discomfort and to assess if students aged from 14 to 19 years old react to discomfort or if they are subjected to it without taking actions. Despite the great variability of the percentages of satisfied people in the selected classrooms, the statistical tests performed on satisfaction and sensation votes regarding thermal environment have shown that the day of the survey has a higher impact on the evaluation than the floor level or the type of heating system. Finally, the analysis reveals that students of secondary schools tend to rely on the teacher to adjust uncomfortable conditions.