Hsiao-Chuan Liu

Dr. Hsiao-Chuan Liu

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 July 2022 in Science
Verified
Journal Article
Closed access
CWChonghe Wang
Chonghe Wang
XCXiaoyu Chen
Xiaoyu Chen
WLWang Liu
Wang Liu
MMMitsutoshi Makihata
Mitsutoshi Makihata
Hsiao-Chuan LiuHsiao-Chuan Liu
Hsiao-Chuan Liu
XZXuanhe Zhao
Xuanhe Zhao
Continuous imaging of internal organs over days could provide crucial information about health and diseases and enable insights into developmental biology. We report a bioadhesive ultrasound (BAUS) device that consists of a thin and rigid ultrasound probe robustly adhered to the skin via a couplant made of a soft, tough, antidehydrating, and bioadhesive hydrogel-elastomer hybrid. The BAUS device provides 48 hours of continuous imaging of diverse internal organs, including blood vessels, muscle, heart, gastrointestinal tract, diaphragm, and lung. The BAUS device could enable diagnostic and monitoring tools for various diseases.

9 February 2024 in Science Advances
Verified
Journal Article
Open access
Hsiao-Chuan LiuHsiao-Chuan Liu
Hsiao-Chuan Liu
YZYushun Zeng
Yushun Zeng
CGchen gong
chen gong
XCXiaoyu Chen
Xiaoyu Chen
PKPiotr Kijanka
Piotr Kijanka
XZXuanhe Zhao
Xuanhe Zhao
Acute liver failure (ALF) is a critical medical condition defined as the rapid development of hepatic dysfunction. Conventional ultrasound elastography cannot continuously monitor liver stiffness over the course of rapidly changing diseases for early detection due to the requirement of a handheld probe. In this study, we introduce wearable bioadhesive ultrasound elastography (BAUS-E), which can generate acoustic radiation force impulse (ARFI) to induce shear waves for the continuous monitoring of modulus changes. BAUS-E contains 128 channels with a compact design with only 24 mm in the azimuth direction for comfortable wearability. We further used BAUS-E to continuously monitor the stiffness of in vivo rat livers with ALF induced byd-galactosamine over 48 hours, and the stiffness change was observed within the first 6 hours. BAUS-E holds promise for clinical applications, particularly in patients after organ transplantation or postoperative care in the intensive care unit (ICU).

1 June 2020 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
PDF file
Hae Gyun LimHae Gyun Lim
Hae Gyun Lim
Hsiao-Chuan LiuHsiao-Chuan Liu
Hsiao-Chuan Liu
CYChi Woo Yoon
Chi Woo Yoon
HJHayong Jung
Hayong Jung
MKMin Gon Kim
Min Gon Kim
KSK. Kirk Shung
K. Kirk Shung
Advancements in diagnostic systems for metastatic cancer over the last few decades have played a significant role in providing patients with effective treatment by evaluating the characteristics of cancer cells. Despite the progress made in cancer prognosis, we still rely on the visual analysis of tissues or cells from histopathologists, where the subjectivity of traditional manual interpretation persists. This paper presents the development of a dual diagnosis and treatment tool using an in vitro acoustic tweezers platform with a 50 MHz ultrasonic transducer for label-free trapping and bursting of human breast cancer cells. For cancer cell detection and classification, the mechanical properties of a single cancer cell were quantified by single-beam acoustic tweezers (SBAT), a noncontact assessment tool using a focused acoustic beam. Cell-mimicking phantoms and agarose hydrogel spheres (AHSs) served to standardize the biomechanical characteristics of the cells. Based on the analytical comparison of deformability levels between the cells and the AHSs, the mechanical properties of the cells could be indirectly measured by interpolating the Young’s moduli of the AHSs. As a result, the calculated Young’s moduli, i.e., 1.527 kPa for MDA-MB-231 (highly invasive breast cancer cells), 2.650 kPa for MCF-7 (weakly invasive breast cancer cells), and 2.772 kPa for SKBR-3 (weakly invasive breast cancer cells), indicate that highly invasive cancer cells exhibited a lower Young’s moduli than weakly invasive cells, which indicates a higher deformability of highly invasive cancer cells, leading to a higher metastasis rate. Single-cell treatment may also be carried out by bursting a highly invasive cell with high-intensity, focused ultrasound.

12 May 2025 in Nature Electronics
Verified
Journal Article
Closed access
PDF file
YZYushun Zeng
Yushun Zeng
CGchen gong
chen gong
Gengxi LuGengxi Lu
Gengxi Lu
Jian-Xing WuJian-Xing Wu
Jian-Xing Wu
XWXiao Wan
Xiao Wan
Qifa ZhouQifa Zhou
Qifa Zhou

26 January 2021 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
Hsiao-Chuan LiuHsiao-Chuan Liu
Hsiao-Chuan Liu
MAMehdi Abbasi
Mehdi Abbasi
YDYong Hong Ding
Yong Hong Ding
TRTuhin Roy
Tuhin Roy
MCMargherita Capriotti
Margherita Capriotti
WBWaleed Brinjikji
Waleed Brinjikji
Thromboembolism in a cerebral blood vessel is associated with high morbidity and mortality. Mechanical thrombectomy (MT) is one of the emergenc proceduresperformed to remove emboli. However, the interventional approaches such as aspiration catheters or stent retriever are empirically selected. An inappropriate selection of surgical devices can influence the success rate during embolectomy, which can lead to an increase in brain damage. There has been growing interest in the study of clot composition and using a priori knowledge of clot composition to provide guidance for an appropriate treatment strategy for interventional physicians. Developing imaging tools which can allow interventionalists to understand clot composition could affect management and device strategy. In this study, we investigated how clots of different compositions can be characterized by using acoustic radiation force optical coherence elastography (ARF–OCE) and compared with ultrasound shear wave elastography (SWE). Five different clots compositions using human blood were fabricated into cylindrical forms from fibrin-rich (21% red blood cells, RBCs) to RBC-rich (95% RBCs). Using the ARF–OCE and SWE, we characterized the wave velocities measured in the time-domain. In addition, the semi-analytical finite element model was used to explore the relationship between the phase velocities with various frequency ranges and diameters of the clots. The study demonstrated that the wave group velocities generally decrease as RBC content increases in ARF–OCE and SWE. The correlation of the group velocities from the OCE and SWE methods represented a good agreement as RBC composition is larger than 39%. Using the phase velocity dispersion analysis applied to ARF–OCE data, we estimated the shear wave velocities decoupling the effects of the geometry and material properties of the clots. The study demonstrated that the composition of the clots can be characterized by elastographic methods using ARF–OCE and SWE, and OCE demonstrated better ability to discriminate between clots of different RBC compositions, compared to the ultrasound-based approach, especially in clots with low RBC compositions.

24 October 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Hsiao-Chuan LiuHsiao-Chuan Liu
Hsiao-Chuan Liu
EGEun Ji Gang
Eun Ji Gang
HKHye Na Kim
Hye Na Kim
Hae Gyun LimHae Gyun Lim
Hae Gyun Lim
HJHayong Jung
Hayong Jung
YKYong-mi Kim
Yong-mi Kim
The role of cell mechanics in cancer cells is a novel research area that has resulted in the identification of new mechanisms of therapy resistance. Single beam acoustic (SBA) tweezers are a promising technology for the quantification of the mechanical phenotype of cells. Our previous study showed that SBA tweezers can be used to quantify the deformability of adherent breast cancer cell lines. The physical properties of patient-derived (primary) pre-B acute lymphoblastic leukemia (ALL) cells involved in chemotherapeutic resistance have not been widely investigated. Here, we demonstrate the feasibility of analyzing primary pre-B ALL cells from four cases using SBA tweezers. ALL cells showed increased deformability with increasing acoustic pressure of the SBA tweezers. Moreover, ALL cells that are resistant to chemotherapeutic drugs were more deformable than were untreated ALL cells. We demonstrated that SBA tweezers can quantify the deformability of nonadherent leukemia cells and discriminate this mechanical phenotype in chemotherapy-resistant leukemia cells in a contact- and label-free manner.