Gh Hamarneh

Dr. Gh Hamarneh


Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2017 in NeuroImage
Verified
Journal Article
Closed access
JKJeremy Kawahara
Jeremy Kawahara
CBColin J. Brown
Colin J. Brown
SMSteven P. Miller
Steven P. Miller
BBBrian G Booth
Brian G Booth
VCVann Chau
Vann Chau
GHGh Hamarneh
Gh Hamarneh

13 June 2020 in Artificial Intelligence Review
Verified
Journal Article
Closed access
PDF file
STSaeid Asgari Taghanaki
Saeid Asgari Taghanaki
KAKumar Abhishek
Kumar Abhishek
JCJoseph Paul Cohen
Joseph Paul Cohen
JCJulien Cohen-Adad
Julien Cohen-Adad
GHGh Hamarneh
Gh Hamarneh

11 July 2011 in Computer Graphics Forum
Verified
Journal Article
Closed access
PDF file
OKOliver van Kaick
Oliver van Kaick
HZHao Zhang
Hao Zhang
GHGh Hamarneh
Gh Hamarneh
DCDaniel Cohen‐Or
Daniel Cohen‐Or

1 July 2019 in Computerized Medical Imaging and Graphics
Verified
Journal Article
Closed access
STSaeid Asgari Taghanaki
Saeid Asgari Taghanaki
YZYefeng Zheng
Yefeng Zheng
SZS. Kevin Zhou
S. Kevin Zhou
BGBogdan Georgescu
Bogdan Georgescu
PSPuneet Sharma
Puneet Sharma
GHGh Hamarneh
Gh Hamarneh

4 October 2019 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
ASAnmol Sharma
Anmol Sharma
GHGh Hamarneh
Gh Hamarneh
Magnetic resonance imaging (MRI) is being increasingly utilized to assess, diagnose, and plan treatment for a variety of diseases. The ability to visualize tissue in varied contrasts in the form of MR pulse sequences in a single scan provides valuable insights to physicians, as well as enabling automated systems performing downstream analysis. However many issues like prohibitive scan time, image corruption, different acquisition protocols, or allergies to certain contrast materials may hinder the process of acquiring multiple sequences for a patient. This poses challenges to both physicians and automated systems since complementary information provided by the missing sequences is lost. In this paper, we propose a variant of generative adversarial network (GAN) capable of leveraging redundant information contained within multiple available sequences in order to generate one or more missing sequences for a patient scan. The proposed network is designed as a multi-input, multi-output network which combines information from all the available pulse sequences and synthesizes the missing ones in a single forward pass. We demonstrate and validate our method on two brain MRI datasets each with four sequences, and show the applicability of the proposed method in simultaneously synthesizing all missing sequences in any possible scenario where either one, two, or three of the four sequences may be missing. We compare our approach with competing unimodal and multi-modal methods, and show that we outperform both quantitatively and qualitatively.

1 June 2020 in Patterns
Verified
Journal Article
Open access
IKIsmail M. Khater
Ismail M. Khater
INIvan Robert Nabi
Ivan Robert Nabi
GHGh Hamarneh
Gh Hamarneh
Single-molecule localization microscopy (SMLM) is a relatively new imaging modality, winning the 2014 Nobel Prize in Chemistry, and considered as one of the key super-resolution techniques. SMLM resolution goes beyond the diffraction limit of light microscopy and achieves resolution on the order of 10–20 nm. SMLM thus enables imaging single molecules and study of the low-level molecular interactions at the subcellular level. In contrast to standard microscopy imaging that produces 2D pixel or 3D voxel grid data, SMLM generates big data of 2D or 3D point clouds with millions of localizations and associated uncertainties. This unprecedented breakthrough in imaging helps researchers employ SMLM in many fields within biology and medicine, such as studying cancerous cells and cell-mediated immunity and accelerating drug discovery. However, SMLM data quantification and interpretation methods have yet to keep pace with the rapid advancement of SMLM imaging. Researchers have been actively exploring new computational methods for SMLM data analysis to extract biosignatures of various biological structures and functions. In this survey, we describe the state-of-the-art clustering methods adopted to analyze and quantify SMLM data and examine the capabilities and shortcomings of the surveyed methods. We classify the methods according to (1) the biological application (i.e., the imaged molecules/structures), (2) the data acquisition (such as imaging modality, dimension, resolution, and number of localizations), and (3) the analysis details (2D versus 3D, field of view versus region of interest, use of machine-learning and multi-scale analysis, biosignature extraction, etc.). We observe that the majority of methods that are based on second-order statistics are sensitive to noise and imaging artifacts, have not been applied to 3D data, do not leverage machine-learning formulations, and are not scalable for big-data analysis. Finally, we summarize state-of-the-art methodology, discuss some key open challenges, and identify future opportunities for better modeling and design of an integrated computational pipeline to address the key challenges.