Junbo Wang

Dr. Junbo Wang

Xi’an University of Architecture and Technology
+1
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2023 in Construction and Building Materials
Verified
Journal Article
Closed access
XWXinyu Wang
Xinyu Wang
CWChong Wang
Chong Wang
PLPengfei Li
Pengfei Li
DTDaopo Tian
Daopo Tian
JWJunbo Wang
Junbo Wang
BLBian Liu
Bian Liu

29 March 2023 in Case Studies in Construction Materials
Verified
Journal Article
Open access
YWYonggui Wang
Yonggui Wang
JCJunhui Cheng
Junhui Cheng
JWJunbo Wang
Junbo Wang

2 January 2026 in Coatings
Verified
Journal Article
Open access
PDF file
XZXianggang Zhang
Xianggang Zhang
JHJunke Huo
Junke Huo
XZXuanxuan Zhang
Xuanxuan Zhang
JWJunbo Wang
Junbo Wang
JNJixiang Niu
Jixiang Niu
LSLei Shi
Lei Shi
As research on fiber-reinforced concrete progresses, investigating the enhancement effect of hybrid fiber-reinforced concrete becomes increasingly crucial. In the present research, the contents of steel fiber (SF) and polypropylene fiber (PP) were set as variable parameters to study the mechanical performance of steel-polypropylene hybrid fiber-reinforced concrete (SPFRC). Mechanical performance tests were undertaken on 16 groups of standard specimens. The failure modes were observed, the strength variation patterns were analyzed, and both a strength prediction equation and a complete stress–strain curve equation were established. Research results indicated that the specimen containing 1.5% SF and 0.25% PP exhibited the maximum strength enhancement compared with plain concrete: cube compressive strength improved by 27.78%, and splitting tensile strength surged by 41.18%. When the SF content was 1.5% and that of PP was 0.5%, the specimen’s elastic modulus experienced the greatest enhancement, reaching 58.59%. Hybrid fibers significantly enhanced the mechanical performance of SPFRC, simultaneously exerting strengthening, crack-resistance, and toughening effects. The research findings offer both experimental evidence and theoretical support for promoting research and engineering applications of SPFRC.

10 February 2017 in Advances in Applied Ceramics: Structural, Functional and Bioceramics
Verified
Journal Article
Closed access
FJFengyang Jiang
Fengyang Jiang
JWJunbo Wang
Junbo Wang
ZAZhaopeng An
Zhaopeng An
XHXin Hai He
Xin Hai He
SLSongtao Liu
Songtao Liu
JLJiangnan Liu
Jiangnan Liu
Biomorphic SiC fabric ceramic was synthesised by in situ reactive molten silicon infiltration process using artificial ramie fibres’ template, phenolic resin, and silicon. The phase compositions, microstructure, and physical characteristics of the biomorphic fabric ceramic were characterised and tested. The results show that the final ceramic retains the ramie fabric structure, and presents duplex microstructure including biomorphic SiC fibres and network SiC ceramic around the biomorphic fibres. This biomorphic SiC fabric ceramic is constituted by 95.8% of SiC, has a low density of 1.02 g cm−3 and a high porosity of 63.7%, and shows low linear shrinkages and better electrical resistivity along the fibre axis. The uniform and fine SiC particles with the size of ∼4 µm indicate that the reaction–formation mechanism is the dissolution of carbon and the precipitation of SiC, without a second precipitation.

1 January 2024 in Structural Control and Health Monitoring
Verified
Journal Article
Open access
LDLin Deng
Lin Deng
XGXinguang Ge
Xinguang Ge
JWJunbo Wang
Junbo Wang
HHHui He
Hui He
Tuned mass damper (TMD) is a single‐terminal damper, while inerter is a two‐terminal one, which are effective control devices. So, a hybrid damper with a series‐parallel inerter system and a TMD (SPIS‐TMD) in series is proposed. The main work of the manuscript is as follows. Firstly, based on the mechanical diagram of SPIS‐TMD and its equipment on the roof of a high‐rise structure, the general form of seismic motion equation was derived using dynamic finite element technology. Secondly, based on the method of quadratic decomposition for power spectrum density function (QD‐PSDF), the concise analytic solutions for zero‐, first‐, and second‐order response spectral moments (ZFSO‐RSMs) of the general response of structure with SPIS‐TMD were deduced. Thirdly, in response to the numerous parameters that affect the safety of high‐rise structures and the varying difficulty for obtaining SPIS‐TMD’s parameters, an optimization analysis technique was proposed, which is constrained by dynamic reliability and SPIS‐TMD’s parameter weights. Finally, three examples were given and results show the following. (1) The proposed analytical solutions for ZFSO‐RSMs are correct and high efficiency and can be extended to analysis of stationary seismic responses of general linear structures. (2) Calculating results of ZFSO‐RSMs of general responses with the number of vibration modes corresponding to a participation weight of 100% is exactly the same as those with all vibration modes, and the calculating time of the case of the participation weight of 100% is less than 1/12 that of the case of all vibration modes. (3) The failure probabilities of the structure with SPIS‐TMD with optimal parameters using the proposed method (with a limit failure probability of 0.1587), the structure only equipped with TMD with the same TMD’s parameters as SPIS‐TMD, and the structure without dampers are 0.1570, 0.7060, and 0.9778, respectively. It indicates that under the same conditions, the hybrid damper SPIS‐TMD has a better damping effect than a single TMD.

15 February 2023 in Atmosphere
Verified
Journal Article
Open access
PDF file
JWJunbo Wang
Junbo Wang
YWYu Wang
Yu Wang
LWLei Wang
Lei Wang
SLShu-Guo Liang
Shu-Guo Liang
The wind-induced responses of tall buildings are stochastic processes, and the peak factor is an important parameter to evaluate the extreme value of the wind-induced response in wind-resistant design. The existing research on the peak factor mainly focuses on the wind pressure on the building surface, but rarely concerns the wind-induced response peak factor of the structures. In view of this, the peak factor of the wind-induced response of super-high-rise buildings was studied in this paper. Firstly, a series of wind tunnel tests of the multi-degree-of-freedom aero-elastic models (MDOF) were carried out, wherein the along-wind and cross-wind responses were measured. Thereafter, the peak factor of wind-induced response was calculated using the peak factor method, classical extreme value theory, and the improved peak factor method. It was found that the peak factor calculated by the improved peak factor method is in good agreement with classical extreme value theory, which indicates that the improved peak factor method is applicable to calculate the peak factor of the wind-induced response of high-rise buildings. The results calculated using the improved peak factor method show that the peak factor of cross-wind response varies significantly with the wind speed, varying from about 2.5 to 5.5. The peak factor of cross-wind response first increases and then decreases with the increase in the wind speed, reaches the minimum near the critical wind speed of vortex-induced vibration (VIV), and increases again when the wind speed is larger than the VIV wind speed. Finally, an empirical formula for the cross-wind response peak factor was proposed as a function of the reduced wind speed, aspect ratio, and damping ratio of the structure.