Shinya Yoshida

Shinya Yoshida

orcid

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 September 2018 in Micromachines
Verified
Journal Article
Open access
PDF file
TPThao Pham
Thao Pham
SYShinya Yoshida
Shinya Yoshida
STShuji Tanaka
Shuji Tanaka
This paper presents a fibered-epitaxial lead zirconate titanate (PZT) thin film with intermediate features between the monocrystalline and polycrystalline thin films for piezoelectric micromachined ultrasound transducer (pMUT). The grain boundaries confirmed by scanning electron microscopy, but it still maintained the in-plane epitaxial relationship found by X-ray diffraction analyses. The dielectric constant (εr33 = 500) was relatively high compared to those of the monocrystalline thin films, but was lower than those of conventional polycrystalline thin films near the morphotropic phase boundary composition. The fundamental characterizations were evaluated through the operation tests of the prototyped pMUT with the fibered-epitaxial thin film. As a result, its piezoelectric coefficient without poling treatment was estimated to be e31,f = −10–−11 C/m2, and thus reasonably high compared to polycrystalline thin films. An appropriate poling treatment increased e31,f and decreased εr33. In addition, this unique film was demonstrated to be mechanically tougher than the monocrystalline thin film. It has the potential ability to become a well-balanced piezoelectric film with both high signal-to-noise ratio and mechanical toughness for pMUT.

25 July 2011 in Nanotechnology
Verified
Journal Article
Closed access
SYShinya Yoshida
Shinya Yoshida
TOTakahito Ono
Takahito Ono
MEMasayoshi Esashi
Masayoshi Esashi
The electrical modification of a conductivity-switching polyimide film via molecular layer deposition (MLD) is studied for ultrahigh density data storage based on a scanning probe microscope (SPM). A PMDA-ODA (PMDA = 1,2,3,5-benzenetetracarboxylic anhydride, ODA = 4,4-oxydianiline) film as a recording medium is uniformly formed from a self-assembled monolayer on a Au surface by MLD. It is demonstrated that the conductivity of the film can be changed by applying a voltage between a SPM probe and the film. This conductivity-switching phenomenon is discussed by the molecular orbital approach and considered to be caused by the charge transfer effect or carrier trapping effect of PMDA-ODA.

19 July 2021 in IEEE Access
Verified
Journal Article
Open access
SYShinya Yoshida
Shinya Yoshida
HMHiroshi Miyaguchi
Hiroshi Miyaguchi
TNTsutomu Nakamura
Tsutomu Nakamura
A safe and affordable ingestible thermometer measuring core body temperature has the potential to become a future healthcare device for versatile applications in daily life. In this study, we developed an ingestible thermometer charged by a gastric acid battery. The device can operate in bowels by using the charged energy in multilayer ceramic capacitors as a storage capacitor. Adopting this strategy for energy storage solves the issues related to a conventional button battery: risk of injury to the digestive tract, bad disposability, and degradation. Additionally, to make it easy to assemble a coil antenna and electrical circuits in the device automatically, we developed a fabrication process based on a vertical stacking process of printed circuit boards with coil patterns. The dimensions of the prototyped device were smaller than those of existing ingestible thermometers. In an experiment involving a dog, we successfully recorded the temperature in the digestive tract for 24 h in cycles of approximately 10 or 20 min, using a rectal thermometer and an existing ingestible thermometer as references. The temperature variations in time among our device, rectal thermometer, and existing ingestible thermometer were almost parallel. The recording ability of the core body temperature using our device has the potential to measure basal body temperature during sleep, the circadian rhythm, and fever type easily and robustly in daily life. Our ingestible thermometer is a step toward the development of sensors that can be swallowed for preventive medicine and health promotion.

20 September 2018 in IEEE Sensors Journal
Verified
Journal Article
Closed access
SYShinya Yoshida
Shinya Yoshida
HMHiroshi Miyaguchi
Hiroshi Miyaguchi
TNTsutomu Nakamura
Tsutomu Nakamura
In this study, we have developed a tablet-shaped ingestible core-body temperature sensor based on gastric acid power generation for daily health care. A custom integrated circuit (IC), which had voltage boosting, bit-rate conversion, coding, modulating, and transmitting functions, was prototyped for the feasibility study of this system. A pair of Mg and Au electrodes was chosen as the negative and positive electrodes for the gastric acid battery, respectively. The battery with a diameter of 2 mm in an artificial gastric juice generated approximately 1.2 V of output voltage. Subsequently, it successfully boosted the generated voltages to more than 3.5 V by the custom IC, and demonstrated the charging of a multilayer ceramic capacitor (MLCC) at the boosted voltage within a reasonably short time. The feasibility of mass production of the Mg thin-film-based battery on a print circuit board (PCB) was also verified through sputter deposition of a Mg thin film on a Au pad of a PCB. Next, electrical components of diameter approximately 7 mm were mounted on the PCBs, and compactly packaged with a resin. Consequently, a tablet-shaped device of diameter 10 mm and height 8 mm was prototyped as a specimen for a telemetry experiment. Finally, we successfully demonstrated that the temperature data measured by the device in pork was transferred to a commercially available loop antenna as a receiver at a distance of more than 20 cm via magnetic-field coupling telecommunication. This achievement paves the way to realizing a safe and ingestible core-body thermometer for daily use.

17 July 2002 in Nano Letters
Verified
Journal Article
Closed access
KKKenkichiro Kobayashi
Kenkichiro Kobayashi
YTYasumasa Tomita
Yasumasa Tomita
SYShinya Yoshida
Shinya Yoshida

11 November 2020 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
PTPham Ngoc Thao
Pham Ngoc Thao
SYShinya Yoshida
Shinya Yoshida
STShuji Tanaka
Shuji Tanaka
This paper describes a new design of piezoelectric micromachined ultrasonic transducer (pMUT) with a monocrystalline Pb(Zr,Ti)O 3 -based thin film (Mono-PZT) for enhancing the mechanical robustness. In this study, we investigated two design concepts to suppress crack generation in Mono-PZT. First, the area of Mono-PZT is limited by leaving an island Mono-PZT pattern only on the membrane of the pMUT. Second, the edge of Mono-PZT is covered with a polyimide (PI) thin film as a protection layer to prevent the peeling. We prepared three different designs, a new design with both concepts, another design with the first concept, and the conventional one with neither of them for comparison. The robust mechanical analyses of these devices were performed by driving resonantly and increasing the displacement of the membranes. As these results, the proposed structure with both concepts still stands well at the highest displacement, 1600 nm, while the undesired cracks occur on other structures with approximately 800 nm of displacement. The robustness could improve 50% in comparison to the other designs thanks to this unique design. Finite element method simulation results showed that this PI layer contributed to decrease the stress concentrated at the edge both in the static condition and in the dyanamic vibarion of the membrane. This layer also probably played a role in prevention of the peeling of the edge of the island-shaped Mono-PZT. In conclusion, the new design is useful for the Mono-PZT pMUT in terms of excellent mechanical robustness.