Cardiac diseases that gives rise to the death and possibly forms the immedicable danger in order to monitor the heart the proposed algorithm is used. An automatic detection of peaks in Electrocardiogram (ECG) signals is presented. The aim of the design work is to achieve higher performance in terms of reliability and better diagnosis of patients through Peak detection. The new method called Modified Pan-Tompkins algorithm based on the slope and amplitude of ECG signal. The QRS complex detection algorithm uses optimized Bandpass-filtering to reduce false detection. The purpose of prefiltering is to reduce various noise components in order to achieve improved detection reliability. The QRS detection reliability of an algorithm was tested with an noisy stress ECG signal. The usefulness of the proposed method is shown by applying the algorithm to signal from MIT- BIH Arrhythmia database to obtain the number of heart-beats per minute which helps to diagnose the heart disease.
20 October 2015 in Circuits, Systems, and Signal Processing
This study presents the adaptive filtering of Electroencephalogram (EEG) signal and epileptic seizure detection using Recurrence Quantification Analysis (RQA). The adaptive filtering is used to remove line frequency artifact from EEG signal in which the parameters can be adjusted to maintain the input output relationship. The filtered output from adaptive filter is compared with the notch filter and wavelet filter and proven to be efficient in terms of Signal to Noise Ratio (SNR). The major advantage of choosing RQA is that, it provides better information even for short non-stationary and non linear signals where other methods fail to provide good results. And it requires no assumptions about data set size or distribution of the data. The algorithm is applied on epileptic EEG signal from CHB MIT database. The RQA measures are determined from the recurrence plot and its performance is measured in terms of sensitivity and specificity as 97.4% and 93.5% respectively.
This study presents the very large scale integration (VLSI) based electrocardiogram (ECG) QRS complex detector for wearable devices in body sensor networks. Multiscale Mathematical Morphology (MMM) is a method used to suppress background noise and baseline wandering from original ECG signal. The major advantage of this method is that it does not require any prior knowledge of frequency spectrum. Hence Multiscale Mathematical Morphology is very attractive for noise reduction. An efficient VLSI architecture in is designed and simulated for the same method. This algorithm is applied to ECG signal from MIT - BIH database and its performance is measured in terms of sensitivity (Se) and positive predictivity (+P) as 97.8% and 97.8% respectively.
1 December 2025 in Journal of Transportation Engineering, Part A: Systems
Most of the Biomedical applications use dedicated processors for the implementation of complex signal processing. Among them, sensor network is also a type, which has the constraint of low power consumption. Since the processing elements are the most copiously used operations in the signal processors, the power consumption of this has the major impact on the system level application. In this paper, we introduce low power concept of transistor stacking to reduce leakage power; and new architectures based on stacking to implement the full adder and its significance at the digital filter level for QRS detector are implemented. The proposed concept has lesser leakage power at the adder as well as filter level with trade-off in other quality metrics of the design. This enabled the design to be dealt with as the low-power corner and can be made adaptable to any level of hierarchical abstractions as per the requirement of the application. The proposed architectures are designed, modeled at RTL level using the Verilog-HDL, and synthesized in Synopsys Design Compiler by mapping the design to 65nm technology library standard cells.