Kouhyar Tavakolian

Prof. Kouhyar Tavakolian

Professor of Biomedical Engineering, University of North Dak...

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 October 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
SSSukhveer Singh Sandhu
Sukhveer Singh Sandhu
HGHamed Taheri Gorji
Hamed Taheri Gorji
PTPantea Tavakolian
Pantea Tavakolian
KTKouhyar Tavakolian
Kouhyar Tavakolian
AAAlireza Akhbardeh
Alireza Akhbardeh
Since its introduction in 2016, researchers have applied the idea of Federated Learning (FL) to several domains ranging from edge computing to banking. The technique’s inherent security benefits, privacy-preserving capabilities, ease of scalability, and ability to transcend data biases have motivated researchers to use this tool on healthcare datasets. While several reviews exist detailing FL and its applications, this review focuses solely on the different applications of FL to medical imaging datasets, grouping applications by diseases, modality, and/or part of the body. This Systematic Literature review was conducted by querying and consolidating results from ArXiv, IEEE Xplorer, and PubMed. Furthermore, we provide a detailed description of FL architecture, models, descriptions of the performance achieved by FL models, and how results compare with traditional Machine Learning (ML) models. Additionally, we discuss the security benefits, highlighting two primary forms of privacy-preserving techniques, including homomorphic encryption and differential privacy. Finally, we provide some background information and context regarding where the contributions lie. The background information is organized into the following categories: architecture/setup type, data-related topics, security, and learning types. While progress has been made within the field of FL and medical imaging, much room for improvement and understanding remains, with an emphasis on security and data issues remaining the primary concerns for researchers. Therefore, improvements are constantly pushing the field forward. Finally, we highlighted the challenges in deploying FL in medical imaging applications and provided recommendations for future directions.

27 March 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
AVAjay K. Verma
Ajay K. Verma
AGAmanmeet Garg
Amanmeet Garg
DXDa Xu
Da Xu
MBMichelle Bruner
Michelle Bruner
RFReza Fazel-Rezai
Reza Fazel-Rezai
KTKouhyar Tavakolian
Kouhyar Tavakolian
The causal interaction between cardio-postural-musculoskeletal systems is critical in maintaining postural stability under orthostatic challenge. The absence or reduction of such interactions could lead to fainting and falls often experienced by elderly individuals. The causal relationship between systolic blood pressure (SBP), calf electromyography (EMG), and resultant center of pressure (COPr) can quantify the behavior of cardio-postural control loop. Convergent cross mapping (CCM) is a non-linear approach to establish causality, thus, expected to decipher nonlinear causal cardio-postural-musculoskeletal interactions. Data were acquired simultaneously from young participants (25 ± 2 years, n = 18) during a 10-minute sit-to-stand test. In the young population, skeletal muscle pump was found to drive blood pressure control (EMG → SBP) as well as control the postural sway (EMG → COPr) through the significantly higher causal drive in the direction towards SBP and COPr. Furthermore, the effect of aging on muscle pump activation associated with blood pressure regulation was explored. Simultaneous EMG and SBP were acquired from elderly group (69 ± 4 years, n = 14). A significant (p = 0.002) decline in EMG → SBP causality was observed in the elderly group, compared to the young group. The results highlight the potential of causality to detect alteration in blood pressure regulation with age, thus, a potential clinical utility towards detection of fall proneness.

5 April 2016 in Cardiovascular Engineering and Technology
Verified
Journal Article
Closed access
PDF file
KTKouhyar Tavakolian
Kouhyar Tavakolian

14 February 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
HGHamed Taheri Gorji
Hamed Taheri Gorji
SSSeyed Mojtaba Shahabi
Seyed Mojtaba Shahabi
ASAkshay Sharma
Akshay Sharma
LTLucas Q. Tande
Lucas Q. Tande
KHKaylee Husarik
Kaylee Husarik
KTKouhyar Tavakolian
Kouhyar Tavakolian
Food safety and foodborne diseases are significant global public health concerns. Meat and poultry carcasses can be contaminated by pathogens like E. coli and salmonella, by contact with animal fecal matter and ingesta during slaughter and processing. Since fecal matter and ingesta can host these pathogens, detection, and excision of contaminated regions on meat surfaces is crucial. Fluorescence imaging has proven its potential for the detection of fecal residue but requires expertise to interpret. In order to be used by meat cutters without special training, automated detection is needed. This study used fluorescence imaging and deep learning algorithms to automatically detect and segment areas of fecal matter in carcass images using EfficientNet-B0 to determine which meat surface images showed fecal contamination and then U-Net to precisely segment the areas of contamination. The EfficientNet-B0 model achieved a 97.32% accuracy (precision 97.66%, recall 97.06%, specificity 97.59%, F-score 97.35%) for discriminating clean and contaminated areas on carcasses. U-Net segmented areas with fecal residue with an intersection over union (IoU) score of 89.34% (precision 92.95%, recall 95.84%, specificity 99.79%, F-score 94.37%, and AUC 99.54%). These results demonstrate that the combination of deep learning and fluorescence imaging techniques can improve food safety assurance by allowing the industry to use CSI-D fluorescence imaging to train employees in trimming carcasses as part of their Hazard Analysis Critical Control Point zero-tolerance plan.

28 May 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Hossein Kashani ZadehHossein Kashani Zadeh
Hossein Kashani Zadeh
Mike HardyMike Hardy
Mike Hardy
MSMitchell Sueker
Mitchell Sueker
YLYicong Li
Yicong Li
ATAngelis Tzouchas
Angelis Tzouchas
CEChris Elliott
Chris Elliott
This study is directed towards developing a fast, non-destructive, and easy-to-use handheld multimode spectroscopic system for fish quality assessment. We apply data fusion of visible near infra-red (VIS-NIR) and short wave infra-red (SWIR) reflectance and fluorescence (FL) spectroscopy data features to classify fish from fresh to spoiled condition. Farmed Atlantic and wild coho and chinook salmon and sablefish fillets were measured. Three hundred measurement points on each of four fillets were taken every two days over 14 days for a total of 8400 measurements for each spectral mode. Multiple machine learning techniques including principal component analysis, self-organized maps, linear and quadratic discriminant analyses, k-nearest neighbors, random forest, support vector machine, and linear regression, as well as ensemble and majority voting methods, were used to explore spectroscopy data measured on fillets and to train classification models to predict freshness. Our results show that multi-mode spectroscopy achieves 95% accuracy, improving the accuracies of the FL, VIS-NIR and SWIR single-mode spectroscopies by 26, 10 and 9%, respectively. We conclude that multi-mode spectroscopy and data fusion analysis has the potential to accurately assess freshness and predict shelf life for fish fillets and recommend this study be expanded to a larger number of species in the future.

13 August 2019 in IEEE Transactions on Aerospace and Electronic Systems
Verified
Journal Article
Closed access
CWchunwu wang
chunwu wang
BGBijay Guragain
Bijay Guragain
AVAjay K. Verma
Ajay K. Verma
LALewis Archer
Lewis Archer
SMShubha Majumder
Shubha Majumder
KTKouhyar Tavakolian
Kouhyar Tavakolian
Drowsiness detection has a significant importance in aviation industry. Electroencephalogram (EEG) has been extensively studied to characterize drowsiness, nevertheless, its behavior with respect to accurately annotated drowsy periods remains to be investigated. At present, Karolinska Sleepiness Scale (KSS) and Psychomotor Vigilance Task (PVT) are widely used references for subjective drowsiness analysis. However, their practical application in real time monitoring of alertness is limited. To address this limitation, we combined Seeing Machines Driver Monitoring System (DMS) and electrooculogram (EOG) for localization of microsleep (MS) events and studied EEG spectral behavior during MS events. EEG, EOG, and facial behavior data were recorded simultaneously from sixteen commercially-rated pilots during simulated flight. Relative spectral power in delta (0.5-4 Hz), theta (4-8 Hz), alpha (8-13 Hz), and beta (13-30 Hz) in frontal, central, temporal, parietal, and occipital brain regions were analyzed. Compared to baseline, delta power reduced during MS (p<0.05 in all regions), alpha power increased during MS (p0.05). The research findings highlight the capability of EEG delta and alpha spectrum towards characterizing MS events, therefore, with consideration to user acceptability, application towards drowsiness detection is plausible via EEG electrodes embedded in the typical aviation headset.