Susanne Martina van der Veen

Dr. Susanne Martina van der Veen

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 August 2019 in Sensors
Verified
Journal Article
Open access
PDF file
SVSusanne Martina van der Veen
Susanne Martina van der Veen
MBMartine Bordeleau
Martine Bordeleau
PPPeter E. Pidcoe
Peter E. Pidcoe
CFChristopher R France
Christopher R France
JTJames S. Thomas
James S. Thomas
Immersive virtual reality has recently developed into a readily available system that allows for full-body tracking. Can this affordable system be used for component tracking to advance or replace expensive kinematic systems for motion analysis in the clinic? The aim of this study was to assess the accuracy of position and orientation measures from Vive wireless body trackers when compared to Vicon optoelectronic tracked markers attached to (1) a robot simulating trunk flexion and rotation by repeatedly moving to know locations, and (2) healthy adults playing virtual reality games necessitating significant trunk displacements. The comparison of both systems showed component tracking with Vive trackers is accurate within 0.68 ± 0.32 cm translationally and 1.64 ± 0.18° rotationally when compared with a three-dimensional motion capture system. No significant differences between Vive trackers and Vicon systems were found suggesting the Vive wireless sensors can be used to accurately track joint motion for clinical and research data.

29 July 2014 in Experimental Brain Research
Verified
Journal Article
Closed access
PDF file
ZPZrinka Potocanac
Zrinka Potocanac
JBJanneke de Bruin
Janneke de Bruin
SVSusanne Martina van der Veen
Susanne Martina van der Veen
SVSabine Verschueren
Sabine Verschueren
Jaap Van DieenJaap Van Dieen
Jaap Van Dieen
MPMirjam Pijnappels
Mirjam Pijnappels

24 November 2020 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
WWWei-En Wang
Wei-En Wang
RHRachel L. M. Ho
Rachel L. M. Ho
BGBryan Gatto
Bryan Gatto
SVSusanne Martina van der Veen
Susanne Martina van der Veen
MUMatthew K. Underation
Matthew K. Underation
SCStephen Coombes
Stephen Coombes
Virtual reality (VR) can be used to create environments that are not possible in the real-world. Producing movements in VR holds enormous promise for rehabilitation and offers a platform from which to understand the neural control of movement. However, no study has examined the impact of a 3D fully immersive head-mounted display (HMD) VR system on the integrity of neural data. We assessed the quality of 64-channel EEG data with and without HMD VR during rest and during a full-body reaching task. We compared resting EEG while subjects completed three conditions: No HMD (EEG-only), HMD powered off (VR-off), and HMD powered on (VR-on). Within the same session, EEG were collected while subjects completed full-body reaching movements in two conditions (EEG-only, VR-on). During rest, no significant differences in data quality and power spectrum were observed between EEG-only, VR-off, and VR-on conditions. During reaching movements, the proportion of components attributed to the brain was greater in the EEG-only condition compared to the VR-on condition. Despite this difference, neural oscillations in source space were not significantly different between conditions, with both conditions associated with decreases in alpha and beta power in sensorimotor cortex during movements. Our findings demonstrate that the integrity of EEG data can be maintained while individuals execute full-body reaching movements within an immersive 3D VR environment. Clinical impact: Integrating VR and EEG is a viable approach to understanding the cortical processes of movement. Simultaneously recording movement and brain activity in combination with VR provides the foundation for neurobiologically informed rehabilitation therapies.

2 August 2022 in Neurology
Verified
Journal Article
Closed access
PDF file
PFPeter Fino
Peter Fino
LDLeland E Dibble
Leland E Dibble
EWElisabeth A. Wilde
Elisabeth A. Wilde
NFNora F. Fino
Nora F. Fino
PJPaula Johnson
Paula Johnson
WWWilliam C. Walker
William C. Walker
Background and Objectives Recent team-based models of care use symptom subtypes to guide treatments of individuals with chronic effects of mild traumatic brain injury (mTBI). However, these subtypes, or phenotypes, may be too broad, particularly for balance (e.g., vestibular subtype). To gain insight into mTBI-related imbalance, we (1) explored whether a dominant sensory phenotype (e.g., vestibular impaired) exists in the chronic mTBI population, (2) determined the clinical characteristics, symptomatic clusters, functional measures, and injury mechanisms that associate with sensory phenotypes for balance control in this population, and (3) compared the presentations of sensory phenotypes between individuals with and without previous mTBI. Methods A secondary analysis was conducted on the Long-Term Impact of Military-Relevant Brain Injury Consortium—Chronic Effects of Neurotrauma Consortium. Sensory ratios were calculated from the sensory organization test, and individuals were categorized into 1 of the 8 possible sensory phenotypes. Demographic, clinical, and injury characteristics were compared across phenotypes. Symptoms, cognition, and physical function were compared across phenotypes, groups, and their interaction. Results Data from 758 Service Members and Veterans with mTBI and 172 individuals with no lifetime history of mTBI were included. Abnormal visual, vestibular, and proprioception ratios were observed in 29%, 36%, and 38% of people with mTBI, respectively, with 32% exhibiting more than 1 abnormal sensory ratio. Within the mTBI group, global outcomes (p < 0.001), self-reported symptom severity (p < 0.027), and nearly all physical and cognitive functioning tests (p < 0.027) differed across sensory phenotypes. Individuals with mTBI generally reported worse symptoms than their non-mTBI counterparts within the same phenotype (p = 0.026), but participants with mTBI in the vestibular-deficient phenotype reported lower symptom burdens than their non-mTBI counterparts (e.g., mean [SD] Dizziness Handicap Inventory = 4.9 [8.1] for mTBI vs 12.8 [12.4] for non-mTBI, group × phenotype interaction p < 0.001). Physical and cognitive functioning did not differ between the groups after accounting for phenotype. Discussion Individuals with mTBI exhibit a variety of chronic balance deficits involving heterogeneous sensory integration problems. While imbalance when relying on vestibular information is common, it is inaccurate to label all mTBI-related balance dysfunction under the vestibular umbrella. Future work should consider specific classification of balance deficits, including specific sensory phenotypes for balance control.

15 August 2018 in Journal of Biomechanics
Verified
Journal Article
Closed access
PDF file
SVSusanne Martina van der Veen
Susanne Martina van der Veen
UHUlrike Hammerbeck
Ulrike Hammerbeck
RBRichard Baker
Richard Baker
KHKristen L. Hollands
Kristen L. Hollands

1 December 2021 in Sensors
Verified
Journal Article
Open access
PDF file
SVSusanne Martina van der Veen
Susanne Martina van der Veen
JTJames S. Thomas
James S. Thomas
Fall rates are increasing among the aging population and even higher falls rates have been reported in populations with neurological impairments. The Berg Balance Scale is often used to assess balance in older adults and has been validated for use in people with stroke, traumatic brain injury, and Parkinson’s disease. While the Berg Balance Scale (BBS) has been found to be predictive of the length of rehabilitation stay following stroke, a recent review concluded the BBS lacked predictive validity for fall risk. Conversely, sophisticated measures assessing center of mass (COM) displacement have shown to be predictive of falls risk. However, calculating COM displacement is difficult to measure outside a laboratory. Accordingly, we sought to validate COM displacement measurements derived from an HTC Vive tracker secured to the pelvis by comparing it to COM derived from ‘gold’ standard laboratory-based full-body motion capture. Results showed that RMS between the COM calculated from HTC Vive tracker and full body motion capture agree with an average error rate of 2.1 ± 2.6 cm. Therefore, we conclude measurement of COM displacement using an HTC Vive tracker placed on the pelvis is reasonably representative of laboratory-based measurement of COM displacement.