This study aims to investigate bacterial adhesion on different titanium and ceramic implant surfaces, to correlate these findings with surface roughness and surface hydrophobicity, and to define the predominant factor for bacterial adhesion for each material. Zirconia and titanium specimens with different surface textures and wettability (5.0 mm in diameter, 1.0 mm in height) were prepared. Surface roughness was measured by perthometer (R a ) and atomic force microscopy, and hydrophobicity according to contact angles by computerized image analysis. Bacterial suspensions of Streptococcus sanguinis and Staphylococcus epidermidis were incubated for 2 h at 37 °C with ten test specimens for each material group and quantified with fluorescence dye CytoX-Violet and an automated multi-detection reader. Variations in surface roughness (R a ) did not lead to any differences in adhering S. epidermidis, but higher R a resulted in increased S. sanguinis adhesion. In contrast, higher bacterial adhesion was observed on hydrophobic surfaces than on hydrophilic surfaces for S. epidermidis but not for S. sanguinis. The potential to adhere S. sanguinis was significantly higher on ceramic surfaces than on titanium surfaces; no such preference could be found for S. epidermidis. Both surface roughness and wettability may influence the adhesion properties of bacteria on biomaterials; in this context, the predominant factor is dependent on the bacterial species. Wettability was the predominant factor for S. epidermidis and surface texture for S. sanguinis. Zirconia did not show any lower bacterial colonization potential than titanium. Arithmetical mean roughness values R a (measured by stylus profilometer) are inadequate for describing surface roughness with regard to its potential influence on microbial adhesion.
Microbial adhesion to intraoral biomaterials is associated with surface roughness. For the prevention of oral pathologies, smooth surfaces with little biofilm formation are required. Ideally, appropriate roughness parameters make microbial adhesion predictable. Although a multitude of parameters are available, surface roughness is commonly described by the arithmetical mean roughness value (Ra). The present study investigates whether Ra is the most appropriate roughness parameter in terms of prediction for microbial adhesion to dental biomaterials. After four surface roughness modifications using standardized polishing protocols, zirconia, polymethylmethacrylate, polyetheretherketone, and titanium alloy specimens were characterized by Ra as well as 17 other parameters using confocal microscopy. Specimens of the tested materials were colonized by C. albicans or S. sanguinis for 2 h; the adhesion was measured via luminescence assays and correlated with the roughness parameters. The adhesion of C. albicans showed a tendency to increase with increasing the surface roughness—the adhesion of S. sanguinis showed no such tendency. Although Sa, that is, the arithmetical mean deviation of surface roughness, and Rdc, that is, the profile section height between two material ratios, showed higher correlations with the microbial adhesion than Ra, these differences were not significant. Within the limitations of this in-vitro study, we conclude that Ra is a sufficient roughness parameter in terms of prediction for initial microbial adhesion to dental biomaterials with polished surfaces.
The formation of biofilms on the surface of dental implants and abutment materials may lead to peri-implantitis and subsequent implant failure. Recently, innovative materials such as polyether-ether-ketone (PEEK) and its modifications have been used as abutment materials. However, there is limited knowledge on microbial adhesion to PEEK materials. The aim of this in vivo study was to investigate biofilm formation on the surface of conventional (titanium and zirconia) and PEEK implant abutment materials. Split specimens of titanium, zirconia, PEEK, and modified PEEK (PEEK-BioHPP) were manufactured, mounted in individual removable acrylic upper jaw splints, and worn by 20 healthy volunteers for 24 h. The surface roughness was determined using widefield confocal microscopy. Biofilm accumulation was investigated by fluorescence microscopy and quantified by imaging software. The surface roughness of the investigated materials was <0.2 µm and showed no significant differences between the materials. Zirconia showed the lowest biofilm formation, followed by titanium, PEEK, and PEEK-BioHPP. Differences were significant (p < 0.001) between the investigated materials, except for the polyether-ether-ketones. Generally, biofilm formation was significantly higher (p < 0.05) in the posterior region of the oral cavity than in the anterior region. The results of the present study show a material-dependent susceptibility to biofilm formation. The risk of developing peri-implantitis may be reduced by a specific choice of abutment material.
Microbial adhesion to oral splints may lead to oral diseases such as candidiasis, periodontitis or caries. The present in vitro study aimed to assess the effect of novel computer-aided design/computer-aided manufacturing (CAD/CAM) and conventional manufacturing on Candida albicans and Streptococcus mutans adhesion to oral splint resins. Standardized specimens of four 3D-printed, two milled, one thermoformed and one pressed splint resin were assessed for surface roughness by widefield confocal microscopy and for surface free energy by contact angle measurements. Specimens were incubated with C. albicans or S. mutans for two hours; a luminometric ATP assay was performed for the quantification of fungal and bacterial adhesion. Both one-way ANOVA with Tukey post hoc testing and Pearson correlation analysis were performed (p < 0.05) in order to relate manufacturing methods, surface roughness and surface free energy to microbial adhesion. Three-dimensional printing and milling were associated with increased adhesion of C. albicans compared to conventional thermoforming and pressing, while the S. mutans adhesion was not affected. Surface roughness and surface free energy showed no significant correlation with microbial adhesion. Increased fungal adhesion to oral splints manufactured by 3D printing or milling may be relevant for medically compromised patients with an enhanced risk for developing candidiasis.
15 May 2022 in Clinical and Experimental Dental Research
Objectives: Evidence on the biocompatibility of three‐dimensional (3D)‐printed and milled resins for oral splints is limited. This in vitro study assessed the influence of the manufacturing method on the cytotoxicity of oral splint resins on L929 cells and human gingival fibroblasts (GF1).Materials and Methods: Standardized specimens of four 3D‐printed, two‐milled, one‐thermoformed, and one‐pressed splint resin were incubated with L929 and GF1 cells for 24 h. Immunofluorescence and WST‐8 assay were performed to evaluate cytotoxic effects. One‐way analysis of variance and Tukey's multiple comparison test were applied with the variables “splint resin” and “manufacturing method” (p < .05).Results: Immunofluorescence showed attachment of L929 and GF1 cells to the splint resins. Irrespective of the manufacturing method, the WST‐8 assay revealed significant differences between splint resins for the viability of L929 and GF1 cells. L929 cells generally showed lower viability rates than GF1 cells. The evaluation of cell viability by the manufacturing method showed no significant differences between 3D printing, milling, and conventional methods.Conclusions: The cytotoxic effects of 3D‐printed, milled, and conventional oral splint resins were similar, indicating minor influence of the manufacturing method on biocompatibility. Cytotoxicity of the resins was below a critical threshold in GF1 cells. The chemical composition might be more crucial than the manufacturing method for the biocompatibility of splint resins.
Objectives: Evidence about modifications of dental luting materials to minimize biological failure at the “marginal gap” between teeth and fixed prosthodontics is scarce. We compared a copper-modified (Co-ZOP) and a conventional zinc oxide phosphate cement (ZOP) in terms of antimicrobial and cytotoxic potentials in vitro and in vivo. Materials and methods: Specimens of ZOP and Co-ZOP were characterized by the mean arithmetic roughness (Ra) and surface free energy (SFE). Powder components were examined using scanning electron microscopy (SEM). Energy-dispersive X-ray spectroscopy (EDX) showed elemental material compositions. In vitro microbial adhesion was shown using SEM, luminescence, and fluorescence assays. CCK-8 assays of mouse fibroblasts (L929) and human gingival fibroblasts (GF-1) were performed after 6, 24, and 48 h of specimen incubation. In vivo, ZOP and Co-ZOP specimens were applied intraorally for 12 h; biofilm accumulation was shown using SEM. Results: Ra of ZOP and Co-ZOP showed no significant differences; SFE was significantly higher for Co-ZOP. EDX exhibited minor copper radiation for Co-ZOP, none for ZOP. In vitro fungal adhesion to Co-ZOP was significantly higher than to ZOP; in vitro streptococcal adhesion, cytotoxicity, and in vivo biofilm formation were not significantly different. Conclusions: Co-ZOP showed low surface allocations of copper with no improved antimicrobial properties compared with conventional ZOP in vitro or in vivo. Clinical relevance: Antimicrobial effects and low cytotoxicity of biomaterials are important for the clinical outcome. Based on our in vitro and in vivo results, no clinical recommendation can be given for the tested Co-ZOP.