Background: For preterm infants, human milk (HM) has to be fortified to cover their enhanced nutritional requirements and establish adequate growth. Most HM fortifiers are based on bovine protein sources (BMF). An HM fortifier based on human protein sources (HMF) has become available in the last few years. The aim of this study is to investigate the impact of an HMF versus BMF on growth in extremely low birth weight (ELBW, <1000 g) infants. Methods: This was a retrospective, controlled, multicenter cohort study in infants with a birthweight below 1000 g. The HMF group received an exclusive HM diet up to 32+0 weeks of gestation and was changed to BMF afterwards. The BMF group received HM+BMF from fortifier introduction up to 37+0 weeks. Results: 192 extremely low birth weight (ELBW)-infants were included (HMF n = 96, BMF n = 96) in the study. After the introduction of fortification, growth velocity up to 32+0 weeks was significantly lower in the HMF group (16.5 g/kg/day) in comparison to the BMF group (18.9 g/kg/day, p = 0.009) whereas all other growth parameters did not differ from birth up to 37+0 weeks. Necrotizing enterocolitis (NEC) incidence was 10% in the HMF and 8% in the BMF group. Conclusion: Results from this study do not support the superiority of HFM over BMF in ELBW infants.
Objective: In continuous positive airway pressure (CPAP) devices, pressure can be generated by two different mechanisms: either via an expiratory valve or by one or more jets. Valved CPAP devices are referred to as constant‐flow devices, and jet devices are called variable‐flow devices. Constant‐flow CPAP devices are said to reduce the imposed work of breathing due to lower breath‐dependent pressure fluctuations. The present study investigates the performance of various constant‐ and variable‐flow CPAP devices in relation to breath‐dependent pressure fluctuations.Design: Experimental study comparing the pressure fluctuations incurred by seven neonatal CPAP devices attached to an active neonatal lung model.Methodology: Spontaneous breathing was simulated using a tidal volume of 6 ml at pressure levels of 5, 7, and 9 mbar. The main outcomes were respiratory pressure fluctuations, tidal volume, and end‐expiratory pressure.Results: All CPAP devices tested showed respiratory pressure fluctuations, varying from 0.631 to 3.466 mbar. The generated tidal volume correlated significantly with the pressure fluctuations (r = −0.947; p = 0.001) and varied between 5.550 and 6.316 ml. CPAP devices with jets showed no advantage over CPAP devices with expiratory valves. End‐expiratory pressure in the nose deviated from the set pressure between −1.305 and 0.644 mbar and varied depending on whether the pressure was measured in the device or in the tube extending to the nose.Conclusion: During standard spontaneous breathing, breath‐dependent pressure fluctuations in constant‐ and variable‐flow devices are comparable. Pressure measurements taken in the tubing system can lead to a considerable deviation of the applied pressure.
Background: In respiratory distress syndrome, many neonatology centers worldwide perform minimal invasive surfactant application in premature infants, using small-diameter catheters for endotracheal intubation and surfactant administration. Methods: In this single-center, open-label, randomized-controlled trial, preterm infants requiring surfactant administration after birth, using a standardized minimal invasive protocol, were randomized to two different modes of endotracheal catheterization: Flexible charrière-4 feeding tube inserted using Magill forceps (group 1) and semi-rigid catheter (group 2). Primary outcome was duration of laryngoscopy. Secondary outcomes were complication rate (intraventricular hemorrhage, soft-tissue damage in first week of life) and vital parameters during laryngoscopy. Between 2019 and 2020, 31 infants were included in the study. Prior to in-vivo testing, laryngoscopy durations were studied on a neonatal airway mannequin in students, nurses and doctors. Results: Mean gestational age and birth weight were 27 + 6/7 weeks and 1009 g; and 28 + 0/7 weeks and 1127 g for group 1 and 2, respectively. Length of laryngoscopy was similar in both groups (61.1 s and 64.9 s) overall (p.77) and adjusted for weight (p.70) or gestational age (p.95). Laryngoscopy failed seven times in group 1 (43.8%) and four times (26.7%) in group 2 (p.46). Longer laryngoscopy was associated with lower oxygen saturation with lowest levels occurring after failed laryngoscopy attempts. Secondary outcomes were similar in both groups. In vitro data on 40 students, 40 nurses and 12 neonatologists showed significant faster laryngoscopy in students and nurses group 2 (p < .0001) unlike in neonatologists (p.13). Conclusion: This study showed no difference in laryngoscopy duration in endotracheal catheterization when comparing semi-rigid and flexible catheters for minimal invasive surfactant application in preterm infants. In accordance with preliminary data and in contrast to published in-vitro trials, experienced neonatologists were able to perform endotracheal catheterization using both semi-rigid and flexible catheters at similar rates and ease, in vitro and in vivo. Trial registration: ClinicalTrials.gov. NCT05024435 Registered 27 August 2021—Retrospectively registered.
1 January 2016 in Journal of Korean Medical Science
Background: Preterm birth accounts for approximately 11% of all livebirths globally. Due to improvements in perinatal care, more than 95% of these infants now survive into adulthood. Research has indicated a robust association between prematurity and increased cardiovascular risk factors and cardiovascular mortality. While the innate adverse effects of prematurity on these outcomes have been demonstrated, therapeutic strategies on the mitigation of these concerning developments are lacking. The primary objective of the NEOVASC clinical trial is therefore to investigate whether the administration of a prolonged exclusive human-milk diet in preterm infants is capable of alleviating the harmful effects of preterm birth on the early development of cardiovascular risk factors.Methods: The NEOVASC study is a multicentric, prospective, randomized, controlled, open, and parallel group clinical trial conducted in four Austrian tertiary neonatal care facilities. The purpose of the present trial is to investigate the effects of a prolonged exclusive human-milk-diet devoid of bovine-milk-based food components on cardiovascular and metabolic risk factors at 1, 2, and 5 years of corrected age. Primary outcomes include assessments of fasting blood glucose levels, blood pressure levels, and the distensibility of the descending aorta using validated echocardiographic protocols at 5 years of corrected age. The test group, which consists of 200 preterm infants, will therefore be compared to a control group of 100 term-born infants and a historical control group recruited previously.Discussion: Given the emerging implications of an increased cardiovascular risk profile in the potentially growing population of preterm infants, further research on the mitigation of long-term morbidities in formerly preterm infants is urgently warranted. Further optimizing preterm infants’ nutrition by removing bovine-milk-based food components may therefore be an interesting approach worth pursuing.Trial registration: ClinicalTrials.govNCT04413994. Registered on 4 June 2020.