We present a comprehensive study of a magnetic sensor system that benefits from a new technique to substantially increase the magnetoelastic coupling of surface acoustic waves (SAW). The device uses shear horizontal acoustic surface waves that are guided by a fused silica layer with an amorphous magnetostrictive FeCoSiB thin film on top. The velocity of these so-called Love waves follows the magnetoelastically-induced changes of the shear modulus according to the magnetic field present. The SAW sensor is operated in a delay line configuration at approximately 150 MHz and translates the magnetic field to a time delay and a related phase shift. The fundamentals of this sensor concept are motivated by magnetic and mechanical simulations. They are experimentally verified using customized low-noise readout electronics. With an extremely low magnetic noise level of ≈100 pT/ $$\sqrt{{\rm{Hz}}}$$ , a bandwidth of 50 kHz and a dynamic range of 120 dB, this magnetic field sensor system shows outstanding characteristics. A range of additional measures to further increase the sensitivity are investigated with simulations.
Magnetoelectric (ME) thin film cantilever type sensors made of AlN and FeCoSiB are operated in vacuum, reducing air damping and thus increasing the ME coefficient and improving the limit of detection (LOD) for ac-magnetic fields. Depending on the sensor geometry, the response is increased by a factor of 5 resulting in a ME coefficient of 20 kV/cmOe at 152 Hz and by a factor of 11 with 12 kV/cmOe at 4.7 kHz and an improvement in LOD by an order of magnitude. Modelling these cantilevers reveals dominant contributions of viscoelastic and molecular damping above and intrinsic damping below 10−2 mbar, respectively.
We demonstrate how to design thin-film multilayer structures that separate multiple wavelength channels with a single stack by spatial dispersion, thus allowing compact manufacturable wavelength multiplexers and demultiplexers and possibly beam-steering or dispersion-control devices. We discuss four types of structure—periodic one-dimensional photonic crystal superprism structures, double-chirped structures exploiting wavelength-dependent penetration depth, coupled-cavity structures with dispersion that is due to stored energy, and numerically optimized nonperiodic structures utilizing a mixture of the other dispersion effects. We experimentally test the spatial dispersion of a 200-layer periodic structure and a 66-layer nonperiodic structure. Probably because of its greater design freedom, the nonperiodic structure can give both a linear shift with wavelength and a larger usable shift than the thicker periodic structure gives.
30 May 2013 in Journal of the American Ceramic Society
We present a handheld biosensor system for the label-free and specific multiplexed detection of several biomarkers employing a spectrometer-free imaging measurement system. A photonic crystal surface functionalized with multiple specific ligands forms the optical transducer. The photonic crystal slab is fabricated on a glass substrate by replicating a periodic grating master stamp with a period of 370 nm into a photoresist via nanoimprint lithography and deposition of a 70-nm titanium dioxide layer. Capture molecules are coupled covalently and drop-wise to the photonic crystal surface. With a simple camera and imaging optics the surface-normal transmission is detected. In the transmission spectrum guided-mode resonances are observed that shift due to protein binding. This shift is observed as an intensity change in the green color channel of the camera. Non-functionalized image sections are used for continuous elimination of background drift. In a first experiment we demonstrate the specific and time-resolved detection of 90.0 nm CD40 ligand antibody, 90.0 nM EGF antibody, and 500 nM streptavidin in parallel on one sensor chip. In a second experiment, aptamers with two different spacer lengths are used as receptor. The binding kinetics with association and dissociation of 250 nM thrombin and regeneration of the sensor surface with acidic tris-HCl-buffer (pH 5.0) is presented for two measurement cycles.