yinfang Zhu

Dr. yinfang Zhu

Institute of Semiconductors, Chinese Academy of Sciences

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2021 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
JZJunyuan Zhao
Junyuan Zhao
LWLihao Wang
Lihao Wang
DFDengyuan Fu
Dengyuan Fu
DZDongyan Zhao
Dongyan Zhao
YWYubo Wang
Yubo Wang
FYFuhua Yang
Fuhua Yang

3 February 2016 in IEEE Sensors Journal
Verified
Journal Article
Closed access
JWJingjing Wang
Jingjing Wang
YZyinfang Zhu
yinfang Zhu
XWXing Wang
Xing Wang
SWShuaipeng Wang
Shuaipeng Wang
JYJinling Yang
Jinling Yang
FYFuhua Yang
Fuhua Yang
A novel microcantilever biosensor was batch-fabricated with integrated circuit compatible micro-electro-mechanical system technology for joint detection of liver cancer biomarkers with high sensitivity, high throughput, high specification, and good precision. A micro-cavity was designed in the free end of the cantilever for local antibody-immobilization using micro-printing system, which can dramatically reduce the effect of adsorption-induced stiffness coefficient $k$ variation. A linear relationship between the resonance frequency shift and the antigen concentration was observed for three liver cancer biomarkers, alpha-fetoprotein, $\gamma $ -glutamyl transpeptidase II, and hepatocyte growth factor. In addition, the presented immunosensing method has little cross reactivity to different antigens, paving the way to a highly specific technique. These approaches will promote clinical application of the cantilever sensors in early cancer diagnosis.

29 July 2019 in Sensors
Verified
Journal Article
Open access
PDF file
XLxiaochen liu
xiaochen liu
LWLihao Wang
Lihao Wang
JZJunyuan Zhao
Junyuan Zhao
YZyinfang Zhu
yinfang Zhu
JYjinling Yang
jinling Yang
FYFuhua Yang
Fuhua Yang
A novel microcantilever sensor was batch fabricated for Yersinia detection. The microcantilever surface modification method was optimized by introducing a secondary antibody to increase the number of binding sites. A novel microfluidic platform was designed and fabricated successfully. A 30 μL solution could fully react with the microcantilever surface. Those routines enhanced the binding efficiency between the target and receptor on the microcantilever. With this novel designed microfluidic platform, the specific adsorption of 107 Yersinia on the beam surface with modified F1 antibody was significantly enhanced.

31 January 2022 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
JLJinchao Li
Jinchao Li
ZCZeji Chen
Zeji Chen
LWLiu Wenli
Liu Wenli
JYjinling Yang
jinling Yang
YZyinfang Zhu
yinfang Zhu
FYFuhua Yang
Fuhua Yang
This work presents a novel ultra-high frequency Lamb mode Aluminum nitride piezoelectric resonator with enhanced quality factors ( Q ). With slots introduced in the vicinity of the tether support end, the elastic waves leaking from the tether sidewalls can be reflected, which effectively reduces the anchor loss while retaining size compactness and mechanical robustness. Comprehensive analysis was carried out to provide helpful guidance for obtaining optimal slot designs. For various resonators with frequencies ranging from 630 MHz to 1.97 GHz, promising Q enhancements up to 2 times have all been achieved. The 1.97 GHz resonator implemented excellent f × Q product up to 6.72 × 10 12 and low motional resistance down to 340 Ω, which is one of the highest performances among the reported devices. The devices with enhanced Q values as well as compact size possess potential application in advanced radio frequency front end transceivers.

1 August 2021 in AIP Advances
Verified
Journal Article
Open access
PDF file
DZDongyan Zhao
Dongyan Zhao
YWYubo Wang
Yubo Wang
JSJin Shao
Jin Shao
PZPeng Zhang
Peng Zhang
YCYanning Chen
Yanning Chen
YZyinfang Zhu
yinfang Zhu
This work presents a monolithically integrated temperature and humidity sensor based on microelectromechanical systems technology. The temperature sensor working on the “bi-metallic” effect has the advantages of wide temperature range, high sensitivity, and fast detection. The humidity sensor has a polyimide parallel plate capacitive structure with the microporous array on the upper electrode designed for high sensitivity and fast response. Numerical analysis and COMSOL simulation showed that the temperature detection sensitivity is 0.2 mV/°C in the range of 193–393 K and humidity sensitivity is 0.405 pF/% relative humidity (RH) with the response time of 34 s in the humidity range of 0%–100% RH. The integrated temperature and humidity sensor has the advantages of small dimension, wide detection range, high precision, and fast response.

7 April 2023 in Sensors
Verified
Journal Article
Open access
PDF file
LWLiu Wenli
Liu Wenli
YLYujie Lu
Yujie Lu
ZCZeji Chen
Zeji Chen
QJQianqian Jia
Qianqian Jia
JZJunyuan Zhao
Junyuan Zhao
FYFuhua Yang
Fuhua Yang
This work presents a silicon-based capacitively transduced width extensional mode (WEM) MEMS rectangular plate resonator with quality factor (Q) of over 10,000 at a frequency of greater than 1 GHz. The Q value, determined by various loss mechanisms, was analyzed and quantified via numerical calculation and simulation. The energy loss of high order WEMs is dominated by anchor loss and phonon-phonon interaction dissipation (PPID). High-order resonators possess high effective stiffness, resulting in large motional impedance. To suppress anchor loss and reduce motional impedance, a novel combined tether was designed and comprehensively optimized. The resonators were batch fabricated based on a reliable and simple silicon-on-insulator (SOI)-based fabrication process. The combined tether experimentally contributes to low anchor loss and motional impedance. Especially in the 4th WEM, the resonator with a resonance frequency of 1.1 GHz and a Q of 10,920 was demonstrated, corresponding to the promising f × Q product of 1.2 × 1013. By using combined tether, the motional impedance decreases by 33% and 20% in 3rd and 4th modes, respectively. The WEM resonator proposed in this work has potential application for high-frequency wireless communication systems.