Muhammad Shoaib

Mr. Muhammad Shoaib


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2016 in Journal of Sensors
Verified
Journal Article
Open access
PDF file
MSMuhammad Shoaib
Muhammad Shoaib
NHNor Hisham Hamid
Nor Hisham Hamid
AMAamir Farooq Malik
Aamir Farooq Malik
NANoohul Basheer Zain Ali
Noohul Basheer Zain Ali
MJMohammad Tariq Jan
Mohammad Tariq Jan
The present review provides information relevant to issues and challenges in MEMS testing techniques that are implemented to analyze the microelectromechanical systems (MEMS) behavior for specific application and operating conditions. MEMS devices are more complex and extremely diverse due to the immersion of multidomains. Their failure modes are distinctive under different circumstances. Therefore, testing of these systems at device level as well as at mass production level, that is, parallel testing, is becoming very challenging as compared to the IC test, because MEMS respond to electrical, physical, chemical, and optical stimuli. Currently, test systems developed for MEMS devices have to be customized due to their nondeterministic behavior and complexity. The accurate measurement of test systems for MEMS is difficult to quantify in the production phase. The complexity of the device to be tested required maturity in the test technique which increases the cost of test development; this practice is directly imposed on the device cost. This factor causes a delay in time-to-market.

1 August 2016 in Microelectronics Reliability
Verified
Journal Article
Closed access
MJMohammad Tariq Jan
Mohammad Tariq Jan
FAFarooq Ahmad
Farooq Ahmad
NHNor Hisham B. Hamid
Nor Hisham B. Hamid
MKMohd Haris B. Md Khir
Mohd Haris B. Md Khir
MSMuhammad Shoaib
Muhammad Shoaib
KAKhalid Ashraf
Khalid Ashraf

25 January 2016 in Analog Integrated Circuits and Signal Processing
Verified
Journal Article
Closed access
PDF file
MSMuhammad Shoaib
Muhammad Shoaib
NHNor Hisham
Nor Hisham
NBNoohul Basheer
Noohul Basheer
MJMohammad Tariq Jan
Mohammad Tariq Jan

9 August 2017 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MSMuhammad Shoaib
Muhammad Shoaib
NHNor Hisham Hamid
Nor Hisham Hamid
MJMohammad Tariq Jan
Mohammad Tariq Jan
NANoohul Basheer Zain Ali
Noohul Basheer Zain Ali
The presence of cracks on the surface of MEMS microelectromechanical system (MEMS) devices affects their functional parameter, such as resonance frequency. Overtime, these cracks may cause the devices’ failure. Therefore, it is important to identify the symptoms of the cracks presence so that the affected devices can be removed/bin-out before delivering to the customers thus avoiding failure during applications of these devices. In this paper, we present a predictive and quantitative fault modeling approach using the linear time invariant (LTI) technique for a piezoelectric cantilever-based sensor. The analytical fault model is developed by correlating single edge, double edge, and surface cracks with the resonance frequency of the cantilever. The Simulink is utilized to design the LTI-based faulty device by integrating the dynamic equations associated to actuation and sensing mechanisms of the device under study. The model is validated by comparing it with the finite element method model containing the same design parameters, using the COMSOL Multiphysics. We observed that the presence of cracks at any location on the surface of the device stimulates the amplitude that causes decrease in its resonance frequency. The increase in the amplitude of vibration due to the presence of cracks is electrically sensed by the piezoresistive mechanism. Finally, the fault detection methodology is presented by using the Stateflow technique. We found that the proposed techniques can be significant to study the faulty behavior of the MEMS devices.

1 February 2016 in Microelectronics Reliability
Verified
Journal Article
Closed access
MJMohammad Tariq Jan
Mohammad Tariq Jan
FAFarooq Ahmad
Farooq Ahmad
NHNor Hisham B. Hamid
Nor Hisham B. Hamid
MKMohd Haris B. Md Khir
Mohd Haris B. Md Khir
KAKhalid Ashraf
Khalid Ashraf
MSMuhammad Shoaib
Muhammad Shoaib

1 September 2013
Verified
Conference Paper
Closed access
AMA. Mirza
A. Mirza
NHN. H. Hamid
N. H. Hamid
MKM. H. Md. Khir
M. H. Md. Khir
John Ojur DennisJohn Ojur Dennis
John Ojur Dennis
KAK. Ashraf
K. Ashraf
MSMuhammad Shoaib
Muhammad Shoaib
Capnometers measure the concentration of CO 2 in exhaled breath which could prevent serious problems in all areas of healthcare, from pre-hospital to extended care, and everywhere in between. Presently, high cost, big size and high power usage limit the scope of the conventional capnometers and their adaption. To overcome these issues, a CMOS MEMS micro-cantilever has been proposed for capnometric applications. Analytical modeling and simulation of the microcantilever sensor is carried out to determine its resonance frequency and sensitivity. According to the developed analytical model and simulation results, the sensor has 1% difference in the resonance frequency. The sensitivity of the sensor is determined analytically at different thicknesses of the polymer coating layer. The sensitivity of the sensor is 3.18 Hz/100ppm at 5 μm polymer layer thickness.