Nilufer Bolukbasi Balcioglu

Dr. Nilufer Bolukbasi Balcioglu

Istanbul University Faculty of Dentistry Department of Oral Implantology
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2015 in Journal of Oral Implantology
Verified
Journal Article
Closed access
NBNilufer Bolukbasi Balcioglu
Nilufer Bolukbasi Balcioglu
SESelim Ersanlı
Selim Ersanlı
NKNurullah Keklikoglu
Nurullah Keklikoglu
CBCansu Basegmez
Cansu Basegmez
TOTayfun Ozdemir
Tayfun Ozdemir
The purpose of this study was to compare the efficacy between the use of bovine bone graft material and platelet-rich fibrin (PRF) mixture (test group) and bovine bone graft material and collagen membrane combination (control group) in 2-stage maxillary sinus augmentation. According to specific inclusion/exclusion criteria, patients treated between 2008 and 2012 were selected. Panoramic radiographs were used for radiologic assessments. To evaluate the relationship between sinus-graft height and each implant, the bone level (BL) was divided by implant length (IL). To evaluate the change in the height of grafted sinus, the grafted sinus floor above the lowest part of the original sinus height (GSH) was divided by the original sinus height (OSH). Samples taken during implant surgery were used for histologic and histomorphometric analyses. Twenty-five patients, 32 augmentation surgeries, and 66 one-stage implants were included in the study. No implant loss or complication was observed in either group. There were no statistical differences according to new bone formation (P = .61) and biomaterial remnant (P = .87). During the evaluation period, the test group showed statistically less change in the BL/IL ratio (P = .022). The difference of GSH/OSH ratio was found to be insignificant between groups (P = .093). It was observed that the grafted sinus covering the implant apex and sinus floor was above the original sinus height in both groups. It may be concluded from this study that both combinations can be successfully used for sinus augmentation. Further studies evaluating different graft materials and PRF combinations in the early phases of healing would be beneficial.

1 December 2013 in Current Therapeutic Research
Verified
Journal Article
Open access
NBNilufer Bolukbasi Balcioglu
Nilufer Bolukbasi Balcioglu
SYSinem Yeniyol
Sinem Yeniyol
MTMerva Soluk Tekkesin
Merva Soluk Tekkesin
KAKemal Altunatmaz
Kemal Altunatmaz
Platelet-rich fibrin (PRF) is a leukocyte and platelet concentrate containing many growth factors. Its potential for hard tissue augmentation as a sole grafting material or in combination with other grafting materials has been investigated in many studies. The aim of this histologic study was to evaluate the efficacy of PRF mixed with biphasic calcium phosphate (BCP) on bone regeneration in surgically created bone defects. Defects 5 mm in diameter were created in both tibias of 6 sheep. The defects were left empty or grafted with BCP, PRF, or BCP+PRF. Animals were killed at 10, 20, and 40 days. The specimens underwent histologic and histomorphometric analysis. None of the groups displayed any signs of necrosis. Inflammation was observed in all groups at 10 days; 2 specimens of PRF+BCP and all empty defects showed inflammatory cell infiltration at 20 days. During the 40-day evaluation period, the PRF+BCP group showed the highest ratios of new bone. The other 3 groups showed statistically similar results. In the BCP and PRF+BCP groups, the residual graft ratios were decreased at consecutive time intervals. The difference between the 2 groups was not statistically significant during follow-up. The current study revealed a histomorphometric increase in bone formation with the addition of PRF to BCP in surgically created defects in sheep tibia.

6 December 2012 in Clinical Oral Investigations
Verified
Journal Article
Closed access
PDF file
Volkan ArısanVolkan Arısan
Volkan Arısan
NBNilufer Bolukbasi Balcioglu
Nilufer Bolukbasi Balcioglu
Lütfiye ÖksüzLütfiye Öksüz
Lütfiye Öksüz

10 January 2022 in Medicina
Verified
Journal Article
Open access
PDF file
NÖNuray Özkahraman
Nuray Özkahraman
NBNilufer Bolukbasi Balcioglu
Nilufer Bolukbasi Balcioglu
MTMerva Soluk Tekkesin
Merva Soluk Tekkesin
YAYusuf Altundağ
Yusuf Altundağ
SYSerdar Yalçın
Serdar Yalçın
Background and Objectives: Dentin grafts have osteoinductive and osteoconductive properties and are considered as an alternative to autogenous graft. This study evaluates the efficacy of autogenous mineralized dentin graft (AMDG) alone or with xenograft and compares it with those of various graft materials used in the treatment of intraosseous bone defects. Materials and Methods: The third incisor teeth of six sheep (2–3 years old) were extracted and AMDG was obtained. Six defects were prepared on each tibia of these six sheep: empty defect (group E); autogenous graft (group A), dentin graft (group D), xenograft (group X), autogenous + xenograft (group A + X) and dentin + xenograft (group D + X). Three sheep in each group were sacrificed in the post-operative 3rd and 6th week and the histologic analyses were performed. Results: The D and D + X groups showed histological features similar to the other groups in the 3rd and 6th weeks. No statistically significant difference was found regarding the rates of new bone formation between the D and D + X groups (p = 1.0) and the other groups at both time intervals (p > 0.05). Conclusions: Similar results observed in this study between groups A, D, X, A + X and D + X demonstrate that AMDG can be successfully used in the treatment of intraosseous bone defects. Further experimental and clinical studies are needed to be able to evaluate the effectiveness of dentin grafts in different types of indications.

9 March 2015 in Medical Engineering & Physics
Verified
Journal Article
Closed access
NBNilufer Bolukbasi Balcioglu
Nilufer Bolukbasi Balcioglu
SYSinem Yeniyol
Sinem Yeniyol
Resorption following tooth loss and poor bone quality affect the success of implants in the anterior maxilla. Inappropriate planning can cause implant loss and aesthetics problems that are difficult to resolve. There is a limited literature on the optimum number and location of implants in anterior maxilla for fabricating fixed prosthesis in biomechanical terms. This study investigated the effect of dental implant localizations in anterior maxilla on the strain values around implants using a three dimensional finite elements analysis method. Obtained strain values were compared to the data in Frost's mechanostat theory. The entire totally edentulous maxilla was modeled using computer tomography images and five models were prepared representing different implant localizations. The distribution of implants in the models was as follows: two canines in the first model, two canines and one central incisor in the second model, two canines and central incisor in the third model, two canines and one lateral incisor in the fourth model and two canines and two lateral incisors in the fifth model. Anatomic abutments with a gingival height of 2 mm and angle of 15° were used as the abutments to fabricate one piece cemented metal fused to porcelain restoration. A chewing strength of 100 N was applied to the cingulum of all crowns at a 45° angle. Maximum strain values in all models were measured in cortical bone in implant necks. The highest strain value was measured in the first model at the cortical bone area (3037 microstrain). Except the first model, all models showed micro strain values within 1000-3000 microstrain. The fifth model was the least risky method in biomechanical terms. The results of this study should be compared with different clinical scenarios (for example different implant designs and sizes). Due to the limitations of three-dimensional finite elements analysis studies, the findings of the study need to be supported by clinical studies.

17 November 2022 in Bioengineering
Verified
Journal Article
Open access
PDF file
NANazlı Ayşeşek
Nazlı Ayşeşek
Volkan ArısanVolkan Arısan
Volkan Arısan
NBNilufer Bolukbasi Balcioglu
Nilufer Bolukbasi Balcioglu
AEAyşe Erol
Ayşe Erol
FKFurkan Kuruoğlu
Furkan Kuruoğlu
SESelim Ersanlı
Selim Ersanlı
The aim of this study was to compare the topographical, chemical and osseointegration characteristics of sandblasting and acid-etching (SLA) surfaces and dental implants treated by boron compounds. Titanium (Ti) disks (n = 20) were modified using boron (B) and boric acid (H3BO3) and then compared with the conventional SLA surface via surface topographic characterizations. Dental implants (3.5 mm in diameter and 8 mm in length) with the experimental surfaces (n = 96) were inserted into the tibias of six sheep, which were left to heal for 3 and 7 weeks. Histologic, histomorphometric (bone–implant contact (BIC%)) and mechanical tests (removal torque value (RTV)) were performed. The boron-coated surface (BC group) was smoother (Rz: 4.51 μm ± 0.13) than the SLA (5.86 μm ± 0.80) and the SLA-B (5.75 μm ± 0.64) groups (p = 0.033). After 3 weeks, the highest mean RTV was found in the SLA group (37 N/cm ± 2.87), and the difference compared with the BC group (30 N/cm ± 2.60) was statistically significant (p = 0.004). After 7 weeks, the mean RTV was >80 N/cm in all groups; the highest was measured in the H3BO3-treated (BS) group (89 N/cm ± 1.53) (p < 0.0001). No statistically significant differences were found in the BIC%s during both healing periods between the groups. H3BO3 seems to be a promising medium for dental implant osseointegration.