Yu-Cheng Wu

Mr. Yu-Cheng Wu

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 August 2020 in IEEE Access
Verified
Journal Article
Open access
WLWei-Yuan Lien
Wei-Yuan Lien
CCChun-Ting Chen
Chun-Ting Chen
MTMing-Jenq Twu
Ming-Jenq Twu
YWYu-Cheng Wu
Yu-Cheng Wu
This paper presents the design, dynamic modeling and motion control of a novel cable-driven upper limb robotic exoskeleton for a rehabilitation exercising. The proposed four degree-of-freedom robotic exoskeleton, actuated by pneumatic artificial muscle actuators, is characterized by a safe, compact, and lightweight structure, complying with the motion of an upper limb as close as possible. In order to perform a passive rehabilitation exercise, the dynamic models were developed by the Lagrange formulation in terms of quasi coordinates combined with the virtual work principle, and then the adaptive fuzzy sliding mode control was designed for the rehabilitation trajectory control. Finally, rehabilitation experiments were conducted to validate the prototype of upper limb robotic exoskeleton and the controller design.

20 October 2026 in Bioengineering
Verified
Journal Article
Open access
PDF file
YWYu-Cheng Wu
Yu-Cheng Wu
LYLO-PING YU
LO-PING YU
SLSi-Huei Lee
Si-Huei Lee
Chun-Ta ChenChun-Ta Chen
Chun-Ta Chen
Sit-to-stand (STS) transfer is fundamental to many activities of daily living, but it is difficult for individuals with motor dysfunction or impairment. This study presents an observer-based impedance-control framework for a lower-limb exoskeleton robot to assist STS transfer. To account for external disturbances, including the wearer’s joint torques and model uncertainties, a nonlinear disturbance observer (NDO) is used to estimate the lumped disturbance. An impedance-control strategy based on adaptive fuzzy sliding mode control (AFSMC) is then used to regulate the human exoskeleton system by compensating for these unknown terms. STS trials were conducted in one healthy participant and three participants with Parkinson’s disease (PD), with and without exoskeleton assistance, to evaluate the proposed system. Across ten trials in the healthy participant, O-AFSMC had the lowest mean hip/knee RMSE (2.1247°/2.9375°). In PD participants, assistance reduced CoP and CoM excursion at the 3-s STS condition in each individual; in the H-Y stage-2 participant, CoP excursion decreased from 25.39 to 15.18 cm and CoM excursion from 17.83 to 14.21 cm. These pilot findings support the feasibility of STS assistance with a lower-limb exoskeleton robot.