Toral Zaveri

Dr. Toral Zaveri


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 July 2014 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
TZToral Zaveri
Toral Zaveri
JHJohn Hayes
John Hayes
GZGregory Ziegler
Gregory Ziegler
Microbicides are an active area of research for HIV prevention, being developed as a woman-initiated method of prevention during unprotected coitus. Along with safety and efficacy, assessing and improving compliance is a major area of research in microbicide development. We have produced microbicide prototypes in the form of semisoft vaginal suppositories prepared from carrageenan and conducted both qualitative and quantitative studies using these prototypes to determine the physical properties that drive acceptability and possibly adherence. In order to ensure that the suppositories function as effective drug delivery vehicles, we have conducted in vitro dissolution studies in water, vaginal simulant fluid (VSF) and semen simulant fluid (SSF) with suppositories loaded with the antiretroviral drug, tenofovir (TFV). TFV was released via diffusion and matrix erosion in water or by diffusion out of the matrix in VSF and SSF. Diffusion studies were conducted in two different volumes of VSF and SSF. The volume of VSF/SSF into which TFV diffused and the size of the suppositories determined the rate of diffusion from the suppositories. About 45%–50% of the encapsulated TFV diffused out of the suppositories within the first two hours, irrespective of suppository size, diffusion medium (VSF/SSF) and the volume of medium. Prior work indicates that a short waiting period between insertion and coitus is highly desired by women; present data suggest our microbicide prototypes have rapid initial release followed by a slow release curve over the first 24 h.

10 September 2014 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
TZToral Zaveri
Toral Zaveri
RPRachel J. Primrose
Rachel J. Primrose
LSLahari Surapaneni
Lahari Surapaneni
GZGregory Ziegler
Gregory Ziegler
JHJohn Hayes
John Hayes
Microbicides are being actively researched and developed as woman-initiated means to prevent HIV transmission during unprotected coitus. Along with safety and efficacy, assessing and improving compliance is a major area of research in microbicide development. We have developed carrageenan-based semisoft vaginal suppositories and have previously evaluated how physical properties such as firmness, size and shape influence women’s willingness to try them. Firmness has previously been quantified in terms of small-strain storage modulus, G’, however large-strain properties of the gels may also play a role in the firmness perception. In the current study we prepared two sets of suppositories with the same G’ but different elongation properties at four different G’ values (250, 2500, 12,500, 25,000 Pa): For convenience we refer to these as “brittle” and “elastic”, although these terms were never provided to study participants. In the first of two tests conducted to assess preference, women compared pairs of brittle and elastic suppositories and indicated their preference. We observed an interaction, as women preferred brittle suppositories at lower G’ (250, 2500 Pa) and elastic ones at a higher G’ (25,000 Pa). In the second test, women evaluated samples across different G’, rated the ease-of-insertion and willingness-to-try and ranked the samples in order of preference. Brittle suppositories at G’ of 12,500 Pa were most preferred. In vitro studies were also conducted to measure the softening of the suppositories in contact with vaginal simulant fluid (VSF). Release of antiretroviral drug tenofovir in VSF was quantified for the brittle and elastic suppositories at G’ of 12,500 Pa to determine the effect of suppository type on release. The initial rate of release was 20% slower with elastic suppositories as compared to brittle suppositories. Understanding how different physical properties simultaneously affect women’s preferences and pharmacological efficacy in terms of drug release is required for the optimization of highly acceptable and efficacious microbicides.

20 October 2018 in BMC Women's Health
Verified
Journal Article
Open access
PDF file
TZToral Zaveri
Toral Zaveri
KPKimberly A Powell
Kimberly A Powell
KGKate M Guthrie
Kate M Guthrie
ABAlyssa Bakke
Alyssa Bakke
GZGregory Ziegler
Gregory Ziegler
JHJohn Hayes
John Hayes
Vaginal microbicides are a promising means to prevent the transmission of HIV and other sexually transmitted infections, by empowering women to initiate use prophylactically when they perceive themselves to be at risk. However, in clinical trials, microbicides have shown mixed results, with the consistent finding that effectiveness varies substantially as a function of user adherence. Based on the assumption that adherence is driven, at least in part, by product properties that influence acceptability, we used softgel technology to develop vaginal drug delivery systems in the intermediate texture space between solids and liquids to overcome potential shortcomings of current dosage forms. Here, we used focus groups and surveys to determine women’s initial reactions (i.e., acceptance and willingness-to-try) for semisoft vaginal suppositories intended for HIV and STI prevention, with a specific focus on how perception of and preferences for vaginal suppositories may be influenced by product characteristics such as size, shape, and firmness. Via focus groups, we identified intrinsic and extrinsic factors relevant to acceptability of semisoft suppository prototypes. Willingness-to-try depended on factors like intended functionality, anticipated leakage, type of sex, recommended frequency of use, type of sexual partner, and perceived risk. When handled ex vivo, shape, size, and firmness of suppositories communicated information about ease of imagined insertion and handling, perceived effectiveness, anticipated awareness and comfort of the product in the body. These impressions were partly based on prior experience with vaginal products. Sensory attributes appear to play a substantial role in women’s preferences and willingness to try the semisoft suppositories. Using these methods during preclinical development should help efficiently optimize a final product that is both biologically efficacious and preferred by women, toward a goal of enhancing adherence and effectiveness.