The present study wants to bring to light a new type of crutch designed for a chronic patient with perennial limited mobility, who must use this support every time a move is needed. The main purpose of the project consists in recommending a correct use of the crutch through technology, limiting the damage normally caused by a bad use of crutches and giving a support both for the patient and for the doctor. All of the features of the crutches were defined through relationship matrices and a benchmarking, which helped us for defining the requirements; other important features were defined, taking a look to the technological progresses applied to new, patented crutches. The result is a sensorized crutch, functional and oriented to meet the user’s needs in order to prevent an incorrect use of the support avoiding the growth of other pains.
Complex deformities of lower limbs are frequent in children with genetic or metabolic skeletal disorders. Early correction is frequently required, but it is technically difficult and burdened by complications and recurrence. Herein, we described the case of a 7-year-old girl affected by severe bilateral genu varum due to spondyloepiphyseal dysplasia. The patient was treated by patient-specific osteotomies and customized structural wedge allograft using Virtual Surgical Planning (VSP) and 3D-printed patient-specific instrumentation (PSI). The entire process was performed through an in-hospital 3D-printing Point-of-Care (POC). VSP and 3D-printing applied to pediatric orthopedic surgery may allow personalization of corrective osteotomies and customization of structural allografts by using low-cost in-hospital POC. However, optimal and definitive alignment is rarely achieved in such severe deformities in growing skeleton through a single operation.
(1) Background: Virtual reality and 3D printing are transforming orthopedic surgery by enabling personalized three-dimensional (3D) models for surgical planning and Patient-Specific Instruments (PSIs). Hospitals are establishing in-house 3D printing centers to reduce costs and improve patient care. Pediatric orthopedic surgery also benefits from these technologies, enhancing the precision and personalization of treatments. This study presents preliminary results of an In-Office 3D Printing Point of Care (PoC), outlining considerations and challenges in using this program for treating lower limb deformities in pediatric patients through Virtual Surgical Planning (VSP) and 3D-printed Patient-Specific Instruments (PSIs). (2) Materials and Methods: Pediatric patients with congenital or acquired lower limb deformities undergoing surgical correction based on VSP, incorporating 3D-printed PSIs when required, were included in this study. The entire process of VSP and 3D printing at the In-Office PoC was illustrated. Data about deformity characteristics, surgical procedures, and outcomes, including the accuracy of angular correction, surgical times, and complications, were reported. (3) Results: In total, 39 bone correction procedures in 29 patients with a mean age of 11.6 ± 4.7 years (range 3.1–18.5 years) were performed according to VSP. Among them, 23 procedures were accomplished with PSIs. Surgeries with PSIs were 45 min shorter, with fewer fluoroscopy shots. Optimal correction was achieved in 37% of procedures, while the remaining cases showed under-corrections (41%) or over-corrections (22%). Major complications were observed in four patients (13.8%). (4) Conclusions: The In-Office 3D Printing Point of Care is becoming an essential tool for planning and executing complex corrections of lower limb deformities, but additional research is needed for optimizing the prediction and accuracy of the achieved corrections.
Torsional deformities of the lower limb are common in children with cerebral palsy (CP)-determining gait problems. The mechanisms underlying transverse plane gait deviations arise from a combination of dynamic and static factors. The dynamic elements may be due to spasticity, contractures and muscle imbalances, while the static ones may result from excessive femoral anteversion, which decreases the efficiency of the hip abductors by reducing the muscular lever arms. A therapeutic approach has been identified in multi-level functional surgery for the lower limb. Treating the malalignments of the lower limb with femoral or tibial derotation provides optimal results, especially when supported by adequate biomechanical planning. This planning requires an integrated static-dynamic approach of morphological and functional evaluation, based on radiological measurements, physical examination and gait analysis. Instrumented gait analysis has been confirmed as essential in the evaluation and surgical decision making process for children affected by CP with transverse plane deformities. Computational simulations based on musculoskeletal models that integrate patient-specific CT morphological data into gait analysis can be used for the implementation of a surgical simulation system in pre-operative planning to test the possible effects of the different surgical treatment options on the torsional defects of the lower limbs. Recently, a computer-aided simulation process has been implemented in the preoperative planning of complex osteotomies for limb deformities in children. Three-dimensional (3D) digital models were generated from Computed Tomography (CT) scans, using free open-source software. The aim of this study is to integrate the patient-specific CT musculoskeletal model with morphological data and gait analysis data, with the personalized calculation of kinematic and kinetic parameters, which allow us to generate an “avatar” of the patient for a more in-depth evaluation of the gait abnormalities. The computational simulation platform proposed provides a realistic movable musculoskeletal model in a virtual environment, with the possibility of planning and monitoring the effects of virtual three-dimensional surgical corrections.
Background: Blount’s disease is a growth disorder of the proximal tibia that causes progressive genu varum in children. Surgical treatment is recommended if the deformity worsens, but which intervention is best remains controversial. This study aims to identify factors influencing outcomes and determine the most effective surgical approach. Methods: A systematic review was conducted of studies published before January 2022. Results: In total, 63 retrospective studies with CEBM IIIb/IV levels were included (1672 knees in 1234 patients). The most commonly reported treatment was acute correction via osteotomy (47%), followed by hemiepiphysiodesis (22%) and gradual correction (18%). Combined procedures were reported in 13% of cases. The overall recurrence rate was 18%, with a significant difference when comparing the recurrence rates after gradual correction with those after hemiepiphysiodesis (7% and 29%, respectively). Major complications beyond recurrence were observed in 5% of cases. A meta-analysis of the available raw data showed a significantly increased recurrence rate (39%) among treated children who were between 4.5 and 11.25 years of age and were followed for a minimum follow-up of 2.5 years. Conclusions: Overall, poor evidence with which to establish an optimal treatment for Blount’s disease was found. This study remarked on the need for early diagnosis, classification, and treatment of infantile tibia vara, since a significant rate of recurrence was found in neglected cases.
The use of external fixators (EFs) for lower limb lengthening is common for treating lower limb length discrepancy (LLD) in children. The concern at present revolves around extended treatment times, with some suggesting a healing index (HI) > 45 days/cm as a major complication. The aim of this study is to assess the factors affecting bone healing and treatment duration in children who undergo limb lengthening for LLD using circular EFs. A total of 240 lengthening procedures on 178 children affected by congenital or acquired LLDs (mean age at surgery 13.8 ± 2.8 years) were retrospectively evaluated. Complications according to Lascombes’ classification and treatment duration factors were analyzed. Mean HI was 57 ± 25 days/cm for the femur and 55 ± 24 days/cm for the tibia, with an HI > 45 days/cm in 64% of the procedures. A total of 189 procedures (79%) reported complications; 85 had an HI > 45 days/cm as the sole complication. While reducing the frame time is crucial, revising the classifications is necessary to avoid the overestimation of complications.