Yinlin Li

Yinlin Li


Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 November 2015 in Cardiology
Verified
Journal Article
Open access
PDF file
YHYasmin S. Hamirani
Yasmin S. Hamirani
BKBijoy Kundu
Bijoy Kundu
MZMin Zhong
Min Zhong
AMAndrew McBride
Andrew McBride
YLYinlin Li
Yinlin Li
JBJamieson M. Bourque
Jamieson M. Bourque
Objectives: Hypertension (HTN) is a common cause of left ventricular hypertrophy (LVH). Sustained pressure overload induces a permanent myocardial switch from fatty-acid to glucose metabolism. In this study, we tested the hypothesis that metabolic remodeling, characterized by increased myocardial glucose uptake, precedes structural and functional remodeling in HTN-induced LVH. Methods: We recruited 31 patients: 11 with HTN only, 9 with HTN and LVH and 11 normotensive controls without LVH. Transthoracic echocardiography was performed to assess the function, mass, wall thickness and diastolic function of the left ventricle. Positron emission tomography imaging was performed, and the rate of myocardial 2-deoxy-2-[18F]fluoro-D-glucose uptake, Ki, was determined using a 3-compartment kinetic model. Results: The mean Ki values were significantly higher in HTN patients than in those with HTN and LVH (p < 0.001) and in controls (p = 0.003). The unexpected decrease in Ki with LVH may be secondary to a decreased Ki with diastolic dysfunction (DD), 0.039 ± 0.032 versus 0.072 ± 0.013 (p = 0.004). There was also a significant stepwise decrease in Ki with increasing DD grade (p = 0.04). Conclusion: Glucose metabolic remodeling is detectable in hypertensive patients before the development of LVH. Furthermore, lower glucose uptake rates are observed in patients with DD. The mechanism for this last finding requires further investigation.

17 June 2020 in Sensors
Verified
Journal Article
Open access
PDF file
XLXujia Liang
Xujia Liang
ZHZhonghua Huang
Zhonghua Huang
LLLiping Lu
Liping Lu
ZTZhigang Tao
Zhigang Tao
BYBing Yang
Bing Yang
YLYinlin Li
Yinlin Li
With the rapid development of autonomous vehicles and mobile robotics, the desire to advance robust light detection and ranging (Lidar) detection methods for real world applications is increasing. However, this task still suffers in degraded visual environments (DVE), including smoke, dust, fog, and rain, as the aerosols lead to false alarm and dysfunction. Therefore, a novel Lidar target echo signal recognition method, based on a multi-distance measurement and deep learning algorithm is presented in this paper; neither the backscatter suppression nor the denoise functions are required. The 2-D spectrogram images are constructed by using the frequency-distance relation derived from the 1-D echo signals of the Lidar sensor individual cell in the course of approaching target. The characteristics of the target echo signal and noise in the spectrogram images are analyzed and determined; thus, the target recognition criterion is established accordingly. A customized deep learning algorithm is subsequently developed to perform the recognition. The simulation and experimental results demonstrate that the proposed method can significantly improve the Lidar detection performance in DVE.

20 October 2017 in Sensors
Verified
Journal Article
Open access
PDF file
MZMengqi Zhu
Mengqi Zhu
ZHZhonghua Huang
Zhonghua Huang
CMChao Ma
Chao Ma
YLYinlin Li
Yinlin Li
Sports-related concussion is a common sports injury that might induce potential long-term consequences without early diagnosis and intervention in the field. However, there are few options of such sensor systems available. The aim of the study is to propose and validate an automated concussion administration and scoring approach, which is objective, affordable and capable of detecting all balance errors required by the balance error scoring system (BESS) protocol in the field condition. Our approach is first to capture human body skeleton positions using two Microsoft Kinect sensors in the proposed configuration and merge the data by a custom-made algorithm to remove the self-occlusion of limbs. The standing balance errors according to BESS protocol were further measured and accessed automatically by the proposed algorithm. Simultaneously, the BESS test was filmed for scoring by an experienced rater. Two results were compared using Pearson coefficient r, obtaining an excellent consistency (r = 0.93, p < 0.05). In addition, BESS test–retest was performed after seven days and compared using intraclass correlation coefficients (ICC), showing a good test–retest reliability (ICC = 0.81, p < 0.01). The proposed approach could be an alternative of objective tools to assess postural stability for sideline sports concussion diagnosis.

4 October 2019 in Sensors
Verified
Journal Article
Open access
PDF file
YXYuan Xu
Yuan Xu
ZHZhonghua Huang
Zhonghua Huang
SYShize Yang
Shize Yang
ZWZhiqi Wang
Zhiqi Wang
BYBing Yang
Bing Yang
YLYinlin Li
Yinlin Li
Intrabody communication (IBC) has drawn extensive attention in the field of ubiquitous healthcare, entertainment, and more. Until now, most studies on the modeling and characterization of capacitive coupling IBC have been conducted in open space, while influences when using metallic-enclosed environments such as a car, airplane, or elevator have not yet been considered. In this paper, we aimed to systematically investigate the grounding effect of an enclosed metal wall of a vehicle on the transmission path loss, utilizing the finite element method (FEM) to model capacitive coupling IBC in an in-vehicle scenario. The results of a simulation and experimental validation indicated that the system gain in an in-vehicle scenario increased up to 7 dB compared to in open space. The modeling and characterization achieved in this paper of capacitive coupling IBC could facilitate an intrabody sensor design and an evaluation with great flexibility to meet the performance needs of an in-vehicle use scenario.

1 September 2015 in Molecular Imaging
Verified
Journal Article
Open access
YLYinlin Li
Yinlin Li
THTao Huang
Tao Huang
XZXinyue Zhang
Xinyue Zhang
MZMin Zhong
Min Zhong
NWNatalie N. Walker
Natalie N. Walker
BKBijoy Kundu
Bijoy Kundu
The goal of this study was to establish a quantitative method for measuring fatty acid (FA) metabolism with partial volume (PV) and spill-over (SP) corrections using dynamic [11C]palmitate positron emission tomographic (PET) images of mouse heart in vivo. Twenty-minute dynamic [11C]palmitate PET scans of four 18- to 20-week-old male C57BL/6 mice under isoflurane anesthesia were performed using a Focus F-120 PET scanner. A model-corrected blood input function, by which the input function with SP and PV corrections and the metabolic rate constants (k1–k5) are simultaneously estimated from the dynamic [11C]palmitate PET images of mouse hearts in a four-compartment tracer kinetic model, was used to determine rates of myocardial fatty acid oxidation (MFAO), myocardial FA esterification, myocardial FA use, and myocardial FA uptake. The MFAO thus measured in C57BL/6 mice was 375.03 ± 43.83 nmol/min/g. This compares well to the MFAO measured in perfused working C57BL/6 mouse hearts ex vivo of about 350 nmol/g/min and 400 nmol/min/g. FA metabolism was measured for the first time in mouse heart in vivo using dynamic [11C]palmitate PET in a four-compartment tracer kinetic model. MFAO obtained with this model was validated by results previously obtained with mouse hearts ex vivo.

8 September 2017 in Sensors
Verified
Journal Article
Open access
PDF file
CMChao Ma
Chao Ma
ZHZhonghua Huang
Zhonghua Huang
ZWZhiqi Wang
Zhiqi Wang
LZLinxuan Zhou
Linxuan Zhou
YLYinlin Li
Yinlin Li
Capacitive coupling intra-body communication (CC-IBC) has become one of the candidates for healthcare sensor networks due to its positive prevailing features of energy efficiency, transmission rate and security. Under the CC-IBC scheme, some of the electric field emitted from signal (SIG) electrode of the transmitter will couple directly to the ground (GND) electrode, acting equivalently as an internal impedance of the signal source and inducing considerable energy losses. However, none of the previous works have fully studied the problem. In this paper, the underlying theory of such energy loss is investigated and quantitatively evaluated using conventional parameters. Accordingly, a method of electric active shielding is proposed to reduce the displacement current across the SIG-GND electrodes, leading to less power loss. In addition, the variation of such loss in regard to frequency range and positions on human body was also considered. The theory was validated by finite element method simulation and experimental measurement. The prototype result shows that the receiving power has been improved by approximate 5.5 dBm while the total power consumption is maximally 9 mW less using the proposed technique, providing an energy efficient option in physical layer for wearable and implantable healthcare sensor networks.