Philip Mckeen

Mr. Philip Mckeen


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 July 2014 in Buildings
Verified
Journal Article
Open access
PDF file
PMPhilip Mckeen
Philip Mckeen
Alan S. FungAlan S. Fung
Alan S. Fung
This paper examines the energy consumption of varying aspect ratio in multi-unit residential buildings in Canadian cities. The aspect ratio of a building is one of the most important determinants of energy efficiency. It defines the building surface area by which heat is transferred between the interior and exterior environment. It also defines the amount of building area that is subject to solar gain. The extent to which this can be beneficial or detrimental depends on the aspect ratio and climate. This paper evaluates the relationship between the geometry of buildings and location to identify a design vernacular for energy-efficient designs across Canada.

15 May 2021 in Building Simulation
Verified
Journal Article
Closed access
PDF file
PMPhilip Mckeen
Philip Mckeen
ZLZaiyi Liao
Zaiyi Liao

24 September 2019 in Buildings
Verified
Journal Article
Open access
PDF file
PMPhilip Mckeen
Philip Mckeen
Zaiyi LiaoZaiyi Liao
Zaiyi Liao
Airflow into stairwells due to stack effect is a concern affecting fire safety, energy performance, and indoor air quality. Stack effect in tall buildings can create significant pressure differentials in vertical shafts when differences in outdoor and indoor temperature exist. The pressure differentials drive air through openings or gaps in walls and floors. Vertical shafts, consisting of stairs and elevators, may transport significant volumes of air. During heating season, this results in the infiltration of cold air at lower floors and the exhaust of warm air on the upper floors. Correspondingly, it results in the spread of air and potential contaminants within the building. Stack effect driven airflow will change according to size and distribution of leakage paths. The size of leakage areas can be approximated by a cross-sectional area of an orifice that would allow equivalent flow. This leakage area is dependent on construction material, workmanship, and even operation, as openings from windows and doors equate to large orifices. A building’s composition of these leakage areas can greatly impact the effective area and airflow. The effect of openings from stairwell doors can change the Neutral Pressure Plane location (NPP), altering airflow patterns within a building. This paper investigates the influence of effective area on airflow within stairwells for multi-unit residential buildings (MURB) due to stack effect. A range of parameters reflective of industry standards are evaluated using network modeling and computational fluid dynamics (CFD). Parametric analysis is used to determine the sensitivity to which they affect airflow between building and stairwells. The effect of airflow within vertical shafts has consequences on indoor air quality (IAQ) and smoke spread, energy efficiency, and thermal comfort. The benefit of reducing leakage in buildings can be understood by comparing the quantity and patterns in airflow in and out of stairwells. Improving air tightness of the building envelope or vertical shafts can have a significant impact on airflow.

17 November 2018 in Building Simulation
Verified
Journal Article
Closed access
PDF file
PMPhilip Mckeen
Philip Mckeen
ZLZaiyi Liao
Zaiyi Liao