José Alexandre Reis

Dr. José Alexandre Reis

Oral Rehabilitation, Instituto Universitário Egas Moniz, Caparica, Portugal
+1
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 November 2024 in Materials
Verified
Journal Article
Open access
PDF file
RARim BEN ABDELADHIM
Rim BEN ABDELADHIM
José Alexandre ReisJosé Alexandre Reis
José Alexandre Reis
AVAna Maria Vieira
Ana Maria Vieira
M. Catarina M.D. De AlmeidaM. Catarina M.D. De Almeida
M. Catarina M.D. De Almeida
Polyhydroxyalkanoates (PHAs) are promising biopolymers as an alternative to traditional synthetic polymers due to their biodegradability and biocompatibility. The PHA market is blooming in response to the growing demand for biodegradable and environmentally friendly plastics. These biopolyesters are produced and degraded by a variety of microorganisms, making them environmentally friendly, while offering benefits such as biocompatibility (when adequately processed) and biodegradability. Their versatility extends to various areas, from biomedicine to agriculture and composite materials, where they pave the way for significative innovations. In the field of regenerative medicine, some PHAs have key applications, namely in vascular grafts, oral tissue regeneration, and development of self-healing polymers. In addition, PHAs have the potential to be used in the creation of dental implant materials and dental medical devices. PHAs can also be used to encapsulate hydrophobic drugs, providing an approach for more targeted and effective treatments. To summarize, PHAs open new perspectives in the field of medicine by improving drug delivery and offering ecologically biocompatible solutions for medical devices. The aim of this review is to present the medical and dental applications of PHA, their advantages, disadvantages, and indications.

1 January 2016 in Procedia Structural Integrity
Verified
Journal Article
Open access
PBP. Bicudo
P. Bicudo
José Alexandre ReisJosé Alexandre Reis
José Alexandre Reis
ADAugusto Moita Deus
Augusto Moita Deus
LRLuis Reis
Luis Reis
MVMaria De Fátima Reis Vaz
Maria De Fátima Reis Vaz
Dental implants are in general made of titanium, since this material promotes a stable and functional connection between the bone and the surface of the implant. Efforts produced during the chewing cycles may interfere with this union, affecting the process of osseointegration and eventually compromising the stability of the implant.Given the difficulty in working with bone in vivo, in the present study two implant systems were inserted in polymer samples, known as Sawbones, which simulate the structure of trabecular bone. The performance of the implants was evaluated through experimental fatigue tests. The qualitative analysis of the damage in the structure of the samples was performed using scanning electron microscope images. Determination and comparison of stress fields and deformations at the Sawbone-implant interface using an analytical model of indentation and the finite element method (FEM) to model indentation and penetration were undertaken.The experimental results showed that the performance of the Morse taper implant was greater than the external hexagonal implant when both were tested cyclically in samples of different densities. It was shown that the diameter, length, density and type of implant-abutment interface affected the behaviour of the implants. The numerical results of indentation model were very similar to those obtained by the analytical model. The results of the FEM penetration model had the same tendency as the experimental values and the indentation analysis with increasing the density of the polymer foam. It could be concluded that, as in foams, the increase of the bone density will induce an increased stability to the implants

1 October 2016 in Theoretical and Applied Fracture Mechanics
Verified
Journal Article
Closed access
PBP. Bicudo
P. Bicudo
José Alexandre ReisJosé Alexandre Reis
José Alexandre Reis
ADAugusto Moita Deus
Augusto Moita Deus
LRLuis Reis
Luis Reis
MVMaria De Fátima Reis Vaz
Maria De Fátima Reis Vaz

1 March 2019 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
Ana Catarina BrancoAna Catarina Branco
Ana Catarina Branco
VMV. Moreira
V. Moreira
José Alexandre ReisJosé Alexandre Reis
José Alexandre Reis
Rogerio ColacoRogerio Colaco
Rogerio Colaco
CCelio Figueiredo-Pina
Celio Figueiredo-Pina
Ana Paula SerroAna Paula Serro
Ana Paula Serro

1 January 2017 in Acta Biomaterialia Odontologica Scandinavica
Verified
Journal Article
Open access
FMFrancisco Martins
Francisco Martins
PBPatrícia Branco
Patrícia Branco
José Alexandre ReisJosé Alexandre Reis
José Alexandre Reis
INIgnacio Barbero Navarro
Ignacio Barbero Navarro
PMPaulo Durão Maurício
Paulo Durão Maurício
Objective: Oral rehabilitation success is enhanced by an accurate and reproducible final impression. The purpose of this study is to evaluate the dimensional changes of a polyether and addition silicone subjected to disinfection and/or sterilization after a long storage period. Material and methods: Ninety samples were obtained from polyether ImpregumTM PentaTM (3M ESPETM, Seefeld, Germany) and 90 of addition silicone ImprintTM 4 PentaTM Putty (3M ESPETM, Seefeld, Germany) according to ISO 4823:2000. The samples of each material were split to form three groups with 30 samples each: a control group, a hypochlorite group (disinfection) and an autoclave group (sterilization). Samples were stored in the Portuguese Institute for Quality for six months at 23 °C. Samples were measured by laser interferometry, according to the Michelson technique before calculating dimensional stability according ISO 4823:2000. A statistical analysis via a three-way mixed ANOVA was performed. Results: Significant shrinkage of ImpregumTM PentaTM was 0.77 ± 0.17% in the control group, 0.42 ± 0.19% in the hypochlorite group and 0.52 ± 0.28% in the autoclave group. For ImprintTM 4 PentaTM Putty, the control group had a shrinkage of 0.42 ± 0.12%, the hypochlorite group 0.36 ± 0.09% and the autoclave group 0.59 ± 0.13%. Conclusions: The long-term storage of samples subjected to disinfection with 5.25% hypochlorite or autoclave sterilization can be used in a clinical setting as the dimensional changes are below the maximum permitted by the ISO 4823:2000, since there are no clinically significant changes in the dimension of the samples during the storage period.

1 August 2019 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
FMFrancisco Martins
Francisco Martins
José Alexandre ReisJosé Alexandre Reis
José Alexandre Reis
INIgnacio Barbero Navarro
Ignacio Barbero Navarro
PMPaulo Durão Maurício
Paulo Durão Maurício
Oral rehabilitation success depends upon the accuracy and dimensional stability of the impressions. The purpose of this study is to evaluate the dimensional changes of a first impression type VPS (Vinyl Polysiloxane) (Imprint™ 4 Preliminary Penta™ Super Quick, 3M ESPE™, St Paul, MN, USA). 10 samples were obtained from this silicone with an automatic mixing machine (Pentamix 2, 3M ESPE™, Seefeld, Germany) according to International Organization for Standardization (ISO) 4823:2000 and stored in the IPQ (Portuguese Institute for Quality) for one week. The measurements were performed by laser interferometry, according to the Michelson technique. The dimensional stability was calculated according to the formula specified in ISO (International Organization for Standardization) 4823:2000. A statistical analysis via a one-way repeated measures ANOVA was performed. The material shrinkage was 0.29 ± 0.15% after setting, 0.32 ± 0.21% at 24 h and 0.30 ± 0.23% after 1 week. No significant shrinkage of the silicone under investigation was found over time. This material can be stored for a week without the risk of clinically significant dimensional changes.