Francisco Martins

Prof. Francisco Martins

CiiEM - Centro de Investigação Interdisciplinar Egas Moniz, Almada, Setúbal, Portugal
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in Acta Biomaterialia Odontologica Scandinavica
Verified
Journal Article
Open access
FMFrancisco Martins
Francisco Martins
PBPatrícia Branco
Patrícia Branco
José Alexandre ReisJosé Alexandre Reis
José Alexandre Reis
INIgnacio Barbero Navarro
Ignacio Barbero Navarro
PMPaulo Durão Maurício
Paulo Durão Maurício
Objective: Oral rehabilitation success is enhanced by an accurate and reproducible final impression. The purpose of this study is to evaluate the dimensional changes of a polyether and addition silicone subjected to disinfection and/or sterilization after a long storage period. Material and methods: Ninety samples were obtained from polyether ImpregumTM PentaTM (3M ESPETM, Seefeld, Germany) and 90 of addition silicone ImprintTM 4 PentaTM Putty (3M ESPETM, Seefeld, Germany) according to ISO 4823:2000. The samples of each material were split to form three groups with 30 samples each: a control group, a hypochlorite group (disinfection) and an autoclave group (sterilization). Samples were stored in the Portuguese Institute for Quality for six months at 23 °C. Samples were measured by laser interferometry, according to the Michelson technique before calculating dimensional stability according ISO 4823:2000. A statistical analysis via a three-way mixed ANOVA was performed. Results: Significant shrinkage of ImpregumTM PentaTM was 0.77 ± 0.17% in the control group, 0.42 ± 0.19% in the hypochlorite group and 0.52 ± 0.28% in the autoclave group. For ImprintTM 4 PentaTM Putty, the control group had a shrinkage of 0.42 ± 0.12%, the hypochlorite group 0.36 ± 0.09% and the autoclave group 0.59 ± 0.13%. Conclusions: The long-term storage of samples subjected to disinfection with 5.25% hypochlorite or autoclave sterilization can be used in a clinical setting as the dimensional changes are below the maximum permitted by the ISO 4823:2000, since there are no clinically significant changes in the dimension of the samples during the storage period.

1 August 2019 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
FMFrancisco Martins
Francisco Martins
José Alexandre ReisJosé Alexandre Reis
José Alexandre Reis
INIgnacio Barbero Navarro
Ignacio Barbero Navarro
PMPaulo Durão Maurício
Paulo Durão Maurício
Oral rehabilitation success depends upon the accuracy and dimensional stability of the impressions. The purpose of this study is to evaluate the dimensional changes of a first impression type VPS (Vinyl Polysiloxane) (Imprint™ 4 Preliminary Penta™ Super Quick, 3M ESPE™, St Paul, MN, USA). 10 samples were obtained from this silicone with an automatic mixing machine (Pentamix 2, 3M ESPE™, Seefeld, Germany) according to International Organization for Standardization (ISO) 4823:2000 and stored in the IPQ (Portuguese Institute for Quality) for one week. The measurements were performed by laser interferometry, according to the Michelson technique. The dimensional stability was calculated according to the formula specified in ISO (International Organization for Standardization) 4823:2000. A statistical analysis via a one-way repeated measures ANOVA was performed. The material shrinkage was 0.29 ± 0.15% after setting, 0.32 ± 0.21% at 24 h and 0.30 ± 0.23% after 1 week. No significant shrinkage of the silicone under investigation was found over time. This material can be stored for a week without the risk of clinically significant dimensional changes.

12 January 2023 in Polymers
Verified
Journal Article
Open access
PDF file
CGCatarina Gomes
Catarina Gomes
FMFrancisco Martins
Francisco Martins
José Alexandre ReisJosé Alexandre Reis
José Alexandre Reis
PMPaulo Durão Maurício
Paulo Durão Maurício
Maria Piedad  Ramirez FernandezMaria Piedad Ramirez Fernandez
Maria Piedad Ramirez Fernandez
The purpose of this study was to evaluate the color changes of feldspathic ceramics CEREC Blocs (Dentsply Sirona, Milford, DE, USA) when cemented with different luting agents, while varying the ceramic thickness. Seventy ceramic discs of feldspathic ceramic (A2 shade) were obtained with 0.5 and 0.8 mm thicknesses. Seventy composite discs (A3 shade) 1 mm in thickness were used as substrates. After being polished and conditioned, the ceramic and composite discs were cemented with different resin cements and a flowable composite: Variolink® Esthetic Light, Neutral and Warm (Ivoclar Vivadent, Schaan, Liechtenstein); RelyXTM Veneer B0.5, Translucent and A3 Opaque/yellow shades (3M Oral Care, St. Paul, MN, USA); G-aenial® Universal Flow A2 (GC Europe, Leuven, Belgium). Color difference (ΔE) was determined using a spectrophotometer. A two-way ANOVA and multiple comparisons were performed using the Bonferroni method with a 95% confidence interval. Variolink® Neutral showed the highest ΔE (15.12 ± 0.71) and RelyXTM Veneer A3 the lowest value (1.59 ± 0.33). There are no statistically significant differences between the two ceramic thicknesses for Variolink® Light (p = 0.230) and RelyXTM Veneer B0.5 (p = 0.318) cements. The feldspathic ceramic final color is influenced by the cement used and the ceramic thickness. The use of different cements in a thin ceramic has a clinically significant impact on the final esthetic result.

28 June 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JPJoana Pereira
Joana Pereira
José Alexandre ReisJosé Alexandre Reis
José Alexandre Reis
FMFrancisco Martins
Francisco Martins
PMPaulo Durão Maurício
Paulo Durão Maurício
M. Victoria FuentesM. Victoria Fuentes
M. Victoria Fuentes
(1) Background: The shade of resin-based materials and ceramic thickness influence the optical color of laminate restorations. The purpose of this study is to evaluate—in vitro—the effect of resin-based cement shade and ceramic thickness on fluorescence of feldspathic laminate veneers; (2) Methods: 180 samples of feldspathic ceramic A2 shade with two different thicknesses (0.5 and 0.8 mm) were obtained. The samples were cemented to composite resin substrates with one of the following materials in different shades (n = 10): resin cement (Variolink Esthetic in Light, Neutral and Warm shades; or RelyX Veneer in B0.5 /white, Translucent and A3 Opaque/yellow opaque shades); flowable composite resin (G-aenial Flo in A2 and A3 shades) or a pre-heated composite resin (Filtek Supreme XTE, A3 body shade). The fluorescence spectra were obtained by means of a spectrofluorometer. Two-way ANOVA, Tukey, and Student’s t-tests were performed (α = 0.05); (3) Results: Fluorescence values were significantly influenced by the resin-based agent tested (p < 0.001), the thickness of ceramic (p < 0.001), and their interaction (p < 0.001). The lowest fluorescence values were achieved by RelyX Veneer resin cement regardless its shade and the ceramic thickness; (4) Conclusions: both the shade of resin-based agent and the feldspathic ceramic thickness influenced the fluorescence of laminate restorations.

9 January 2022 in Clinical and Experimental Dental Research
Verified
Journal Article
Open access
PDF file
CGCatarina Gomes
Catarina Gomes
FMFrancisco Martins
Francisco Martins
José Alexandre ReisJosé Alexandre Reis
José Alexandre Reis
CMCarlos Pérez-Albacete Martínez
Carlos Pérez-Albacete Martínez
PMPaulo Durão Maurício
Paulo Durão Maurício
Objective: The purpose of this study is to evaluate the color changes of lithium disilicate ceramics when cemented with different brands of cement by varying the thickness of the ceramic.Materials and Methods: Forty ceramic discs, shade A2, were fabricated with 0.5 and 0.8 mm thickness. Forty composite resin discs, shade A3, were also produced. The ceramic samples were cemented to the composite resin discs, with two colors of resin cement, Neutral and Warm. A spectrophotometer evaluation was made. Translucency and color change analysis was performed by calculating the ΔE. A two‐way analysis of variance test and multiple comparisons were performed using the Bonferroni method with a 95% confidence interval.Results: There are statistically significant differences between the two ceramic thicknesses with different brands of cement (p < .001). In addition, using the translucency analysis it was found that there are statistically significant differences between the two ceramic thicknesses in both types of cement (p < .001).Conclusions: The use of different cementation materials on lithium disilicate ceramics appears to have little visible influence at the clinical level. Different ceramic thicknesses have a clinically visible influence on the final restoration color.

11 July 2019 in Tribology Letters
Verified
Journal Article
Closed access
PDF file
Ana Catarina BrancoAna Catarina Branco
Ana Catarina Branco
JBJ. Brito
J. Brito
MCM. Codorniz
M. Codorniz
MSM. Steinhausen
M. Steinhausen
FMFrancisco Martins
Francisco Martins
Ana Paula SerroAna Paula Serro
Ana Paula Serro