Jaanus Hallik

Jaanus Hallik


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

19 July 2019 in Buildings
Verified
Journal Article
Open access
PDF file
JHJaanus Hallik
Jaanus Hallik
HGHeleen Gustavson
Heleen Gustavson
TKTargo Kalamees
Targo Kalamees
Air leakage through the building envelope joints is usually one of the main reasons why airtightness targets are not achieved. The objective of this study was to analyse the air leakage of joints filled with polyurethane foam and its influencing factors. Wooden test specimens (54 in total) with planed, sawn and plastic-coated cavities and two cavity thicknesses were filled with three different polyurethane foams and tested according to standard EN 12114. The surface type and thickness of the joint had a significant effect on the air leakage of joints filled with polyurethane foam. In laboratory conditions, a consistent and very low air leakage rate was obtained with planed timber surfaces. Joints with plastic-coated and sawn timber surfaces performed worse, on average, by a factor of two or more and contributed to very variable airtightness, with up to 28% and 50% of the test specimens failing the airtightness testing. On the basis of the high ‘failure rate’, polyurethane foam may classify as a not completely trustworthy solution in guaranteeing the airtightness of construction joints. A comparison of estimated and previously measured overall airtightness of an entire building envelope showed dependency on ‘failure rate’ rather than on average measured leakage rate.


30 June 2020
Verified
Conference Paper
Open access
PDF file
JHJaanus Hallik
Jaanus Hallik
TKTargo Kalamees
Targo Kalamees
A well-insulated, airtight and thermal bridge free building envelope is a key factor for nearly zero energy buildings (nZEB). However, increased insulation thickness and minimized air leakages increase the effect of thermal bridges on overall energy efficiency of the nZEBs. Although several more prominent linear thermal bridges are accounted for in the practice the three-dimensional heat flow through vast array of fixation elements, mounting brackets and other point thermal bridges are usually neglected due to time-consuming model preparation routine, lack of input data as well as high number of different thermal bridges that have to be assessed for a single project. In this study a new method was proposed for predicting three-dimensional heat flow and the point thermal transmittance of thermal bridges caused by full or partial penetration of the building envelope with metal elements with uniform geometry in third dimension based on multiple two-dimensional numerical heat flow calculations. A new parameter (equivalent length of thermal bridge) was defined which incorporates the effect of additional thermal transmittance in third dimension when multiplied by the difference of two thermal coupling coefficients derived for two-dimensional cross section. Multiple linear regression model was fitted on database with 102 cases and verified with separate case of window to wall connection incorporating metal penetration at fixation points. The proposed methodology can be useful in general practice where the design team lacks the skills or software tools for conducting detailed numerical analysis in three dimensions.

7 September 2022 in Journal of Building Engineering
Verified
Journal Article
Closed access
JHJaanus Hallik
Jaanus Hallik
PKPaul Klõšeiko
Paul Klõšeiko
RPReimo Piir
Reimo Piir
TKTargo Kalamees
Targo Kalamees

1 September 2026 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
JHJaanus Hallik
Jaanus Hallik
KKKristo Kalbe
Kristo Kalbe
TKTargo Kalamees
Targo Kalamees
Airtightness of the building envelope is critical for reducing energy use, limiting convective moisture transport, improving indoor air quality and safeguarding the durability of building components. Despite two decades of regulatory airtightness requirements in Estonia, the absence of coherent national guidance has led to inconsistent on-site results and frequent underperformance relative to design assumptions. The new standard prEVS 946:2025 Guidance for improvement of building-envelope airtightness measures addresses this gap through an action-research process involving cyclic literature review, field measurements and stakeholder feedback. The standard introduces a process-oriented framework covering both new construction and renovation: it assigns clear responsibilities to a client-appointed airtightness specialist and a planner-side specialist and establishes mandatory phase-based deliverables from the project brief through intermediate blower-door testing to final verification in accordance with ISO 9972. The standard includes a large collection of illustrated examples of good and bad practice, covering material selection, junction detailing, installation quality and common failure modes. Field measurements in newly completed apartment buildings confirm that leakage is systematic rather than random, concentrated at window and door junctions, balcony connections, service penetrations and roof–wall interfaces, however object-specific other failures can occur. Measurements tracking one construction company over five years with recorded values between 0.67 and 1.45 m 3 /(h·m 2 ) demonstrate that a systematic approach yields steady airtightness improvement. The selected central performance criterion for air permeability at q E50 ≤ 1 m 3 /(h·m 2 ) for new energy-efficient buildings, balance ambition with practicality: they are stringent enough to deliver measurable energy and moisture-safety benefits while remaining achievable with coordinated practice.