Amani A. Fawzi

Amani A. Fawzi

orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Ophthalmology
Verified
Journal Article
Closed access
CFChristina J. Flaxel
Christina J. Flaxel
RARon A. Adelman
Ron A. Adelman
SBSteven T. Bailey
Steven T. Bailey
AFAmani A. Fawzi
Amani A. Fawzi
JLJennifer I. Lim
Jennifer I. Lim
GYGui-Shuang Ying
Gui-Shuang Ying

1 October 2013 in JAMA Ophthalmology
Verified
Journal Article
Closed access
PDF file
DSDavid Sarraf
David Sarraf
EREhsan Rahimy
Ehsan Rahimy
AFAmani A. Fawzi
Amani A. Fawzi
ESElliott H Sohn
Elliott H Sohn
IBIrene Barbazetto
Irene Barbazetto
KFK. Bailey Freund
K. Bailey Freund
Research from JAMA Ophthalmology — Paracentral Acute Middle Maculopathy — A New Variant of Acute Macular Neuroretinopathy Associated With Retinal Capillary Ischemia

1 October 2016 in Ophthalmology
Verified
Journal Article
Open access
LCLyndon da Cruz
Lyndon da Cruz
JDJessy D. Dorn
Jessy D. Dorn
MHMark S. Humayun
Mark S. Humayun
GDGislin Dagnelie
Gislin Dagnelie
JHJames Handa
James Handa
RGRobert J. Greenberg
Robert J. Greenberg
The Argus II Retinal Prosthesis System (Second Sight Medical Products, Inc, Sylmar, CA) was developed to restore some vision to patients blind as a result of retinitis pigmentosa (RP) or outer retinal degeneration. A clinical trial was initiated in 2006 to study the long-term safety and efficacy of the Argus II System in patients with bare or no light perception resulting from end-stage RP. Prospective, multicenter, single-arm clinical trial. Within-patient controls included the nonimplanted fellow eye and patients' native residual vision compared with their vision with the Argus II. Thirty participants in 10 centers in the United States and Europe. The worse-seeing eye of blind patients was implanted with the Argus II. Patients wore glasses mounted with a small camera and a video processor that converted images into stimulation patterns sent to the electrode array on the retina. The primary outcome measures were safety (the number, seriousness, and relatedness of adverse events) and visual function, as measured by 3 computer-based, objective tests. Secondary measures included functional vision performance on objectively scored real-world tasks. Twenty-four of 30 patients remained implanted with functioning Argus II Systems at 5 years after implantation. Only 1 additional serious adverse event was experienced after the 3-year time point. Patients performed significantly better with the Argus II on than off on all visual function tests and functional vision tasks. The 5-year results of the Argus II trial support the long-term safety profile and benefit of the Argus II System for patients blind as a result of RP. The Argus II is the first and only retinal implant to have market approval in the European Economic Area, the United States, and Canada.

1 January 2020 in Ophthalmology
Verified
Journal Article
Closed access
CFChristina J. Flaxel
Christina J. Flaxel
RARon A. Adelman
Ron A. Adelman
SBSteven T. Bailey
Steven T. Bailey
AFAmani A. Fawzi
Amani A. Fawzi
JLJennifer I. Lim
Jennifer I. Lim
GYGui-Shuang Ying
Gui-Shuang Ying

1 May 2017 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
PNPeter L. Nesper
Peter L. Nesper
PRPhilipp K. Roberts
Philipp K. Roberts
AOAlex C. Onishi
Alex C. Onishi
HCHaitao Chai
Haitao Chai
LLLei Liu
Lei Liu
AFAmani A. Fawzi
Amani A. Fawzi
Purpose: We quantified retinal and choriocapillaris microvascular changes in healthy control eyes and different stages of diabetic retinopathy (DR) using optical coherence tomography angiography (OCTA). Methods: This retrospective cross-sectional study included 137 eyes of 86 patients with different stages of DR and 44 eyes of 26 healthy age-matched controls. Participants were imaged with a commercial OCTA device (RTVue-XR Avanti). We analyzed the superficial (SCP) and deep (DCP) retinal capillary plexus, the full retina, and choriocapillaris for the following OCTA parameters: foveal avascular zone, vessel density, percent area of nonperfusion (PAN), and adjusted flow index (AFI). We adjusted for age, sex, and the correlation between eyes of the same study participant in our statistical models. Results: All OCTA parameters showed a significant linear correlation with DR severity (P < 0.05) in the univariate models except for AFI measured in the SCP and these correlations remained significant after correcting for covariates. Compared to the other capillary layers, the AFI at the DCP decreased significantly with DR severity. When comparing individual disease severity groups as categories, eyes of subjects with diabetes without DR had significantly increased PAN and AFI in the SCP compared to healthy subjects (P < 0.05). Conclusions: Retinal and choriocapillaris vascular nonperfusion in OCTA is correlated significantly with disease severity in eyes with DR. Higher flow in the SCP may be an early marker of diabetic microvascular changes before clinical signs of DR. The steep decline of blood flow in the DCP with increasing DR severity suggests that alterations at the DCP warrant further investigation.

12 February 2010 in Optics Express
Verified
Journal Article
Open access
PDF file
SJShuliang Jiao
Shuliang Jiao
MJMinshan Jiang
Minshan Jiang
JHJianming Hu
Jianming Hu
AFAmani A. Fawzi
Amani A. Fawzi
QZQifa Zhou
Qifa Zhou
HZHao F. Zhang
Hao F. Zhang
We have developed a non-invasive photoacoustic ophthalmoscopy (PAOM) for in vivo retinal imaging. PAOM detects the photoacoustic signal induced by pulsed laser light shined onto the retina. By using a stationary ultrasonic transducer in contact with the eyelids and scanning only the laser light across the retina, PAOM provides volumetric imaging of the retinal micro-vasculature and retinal pigment epithelium at a high speed. For B-scan frames containing 256 A-lines, the current PAOM has a frame rate of 93 Hz, which is comparable with state-of-the-art commercial spectral-domain optical coherence tomography (SD-OCT). By integrating PAOM with SD-OCT, we further achieved OCT-guided PAOM, which can provide multi-modal retinal imaging simultaneously. The capabilities of this novel technology were demonstrated by imaging both the microanatomy and microvasculature of the rat retina in vivo.