Peng Yu

Peng Yu

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2016 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
PYPeng Yu
Peng Yu
YLYunqing Liu
Yunqing Liu
Xiaohua ZhangXiaohua Zhang
Xiaohua Zhang
JZJiawan Zhou
Jiawan Zhou
EXErhu Xiong
Erhu Xiong
JCJinhua Chen
Jinhua Chen

1 October 2014 in Journal of Electroanalytical Chemistry
Verified
Journal Article
Closed access
PYPeng Yu
Peng Yu
JZJiawan Zhou
Jiawan Zhou
LWLiang Wu
Liang Wu
EXErhu Xiong
Erhu Xiong
XZXiaohua Zhang
Xiaohua Zhang
JCJinhua Chen
Jinhua Chen

4 November 2015 in Scientific Reports
Verified
Journal Article
Open access
PDF file
PYPeng Yu
Peng Yu
XZXiaohua Zhang
Xiaohua Zhang
JZJiawan Zhou
Jiawan Zhou
EXErhu Xiong
Erhu Xiong
XLXiaoyu Li
Xiaoyu Li
JCJinhua Chen
Jinhua Chen
A novel competitive host-guest strategy regulated by protein biogate was developed for sensitive and selective analysis of prion protein. The methylene blue (MB)-tagged prion aptamer (MB-Apt) was introduced to the multiwalled carbon nanotubes-β-cyclodextrins (MWCNTs-β-CD) composites-modified glassy carbon (GC) electrode through the host-guest interaction between β-CD and MB. In the absence of prion, MB-Apt could be displaced by ferrocenecarboxylic acid (FCA) due to its stronger binding affinity to β-CD, resulting in a large oxidation peak of FCA. However, in the presence of prion, the specific prion-aptamer interaction drove the formation of protein biogate to seal the cavity of β-CD, which hindered the guest displacement of MB by FCA and resulted in the oxidation peak current of MB (IMB) increased and that of FCA (IFCA) decreased. The developed aptasensor showed good response towards the target (prion protein) with a low detection limit of 160 fM. By changing the specific aptamers, this strategy could be easily extended to detect other proteins, showing promising potential for extensive applications in bioanalysis.

1 November 2016 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
PYPeng Yu
Peng Yu
Xiaohua ZhangXiaohua Zhang
Xiaohua Zhang
EXErhu Xiong
Erhu Xiong
JZJiawan Zhou
Jiawan Zhou
XLXiaoyu Li
Xiaoyu Li
JCJinhua Chen
Jinhua Chen

21 September 2019 in Sensors
Verified
Journal Article
Open access
PDF file
PYPeng Yu
Peng Yu
MDMuhan Deng
Muhan Deng
Yi YangYi Yang
Yi Yang
A simple, low-cost technique has been developed for the rapid fabrication of single-layered paper-based microfluidic devices (μPADs). This technique, for the first time, made use of the deposition of patterned adhesive tape into the filter paper to construct hydrophobic barriers, with the help of toluene. Unlike other reported multi-layered μPADs that merely made use of adhesive tape as a separate layer for sealing or fluid flow controlling, the patterned adhesive tape was simultaneously dissolved and penetrated into the filter paper, which resulted in the successful transfer of the pattern from the tape to the filter paper. To demonstrate the effectiveness of this approach, nitrite and glucose were individually measured; detection limits as low as 0.015 ± 0.004 mM and 0.022 ± 0.006 mM were reported for nitrite and glucose, respectively. Multiplexed analysis of both analytes was also carried out with respective detection limits of 0.048 ± 0.005 mM and 0.025 ± 0.006 mM for nitrite and glucose. The application of the method was demonstrated by measuring nitrite and glucose in spiked artificial urine samples and satisfied recovery results were obtained.

24 July 2020 in Sensors
Verified
Journal Article
Open access
PDF file
PYPeng Yu
Peng Yu
MDMuhan Deng
Muhan Deng
Yi YangYi Yang
Yi Yang
BNBeixi Nie
Beixi Nie
SZShaoyu Zhao
Shaoyu Zhao
The concentrations of nitrite and thiocyanate in saliva can be used as the biomarkers of the progression of periodontitis disease and environmental tobacco smoke exposure, respectively. Therefore, it is particularly necessary to detect these two indicators in saliva. Herein, the three-dimensional single-layered paper-based microfluidic analytical devices (3D sl-μPADs) were, for the first time, fabricated by the spraying technique for the colorimetric detection of nitrite and thiocyanate at the same time. The conditions for 3D sl-μPADs fabrication were optimized in order to well control the penetration depth of the lacquer in a paper substrate. Then, the developed 3D sl-μPADs were utilized to simultaneously detect nitrite and thiocyanate and the limits of detection are 0.0096 and 0.074 mM, respectively. What is more, the μPADs exhibited good specificity, good repeatability, and acceptable recoveries in artificial saliva. Therefore, the developed 3D sl-μPADs show a great potential to determine nitrite and thiocyanate for the assessment of the human health.