Ting Ting Fu

Dr. Ting Ting Fu

Division of Neonatology, Perinatal Institute Cincinnati Children’s Hospital Medical Center, 3333 Burnet Avenue MLC 7009, Cincinnati, OH 45229, USA
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2020 in Clinical Nutrition
Verified
Journal Article
Open access
CKCelia Kwan
Celia Kwan
GFGerhard Fusch
Gerhard Fusch
NRNiels Rochow
Niels Rochow
CFChristoph Fusch
Christoph Fusch
SES. El-Helou
S. El-Helou
OBO. Barbarska
O. Barbarska
Human milk analyzers are increasingly used to rapidly measure the macronutrient content in breast milk for individual target fortification, to reduce the risk of postnatal growth restriction. However, many milk analyzers are used without calibration, validation or quality assurance. To investigate measurement quality between different human milk analyzers, to test whether accuracy and precision of devices can be improved by establishing individual calibration curves, and to assess long-term stability of measurements, following good clinical laboratory practice (GCLP). Sets of identical breast milk samples were sent to 13 participating centres in North America and Europe, for a total of 15 devices. The study included 3 sets of samples: A) initial assessment of the device's performance consisting of 10 calibration samples with random replicates; B) long term stability and quality control consisting of 2 batches of samples to be measured every time before the device is used, over 6 months; C) ring trial consisting of 2 samples to be measured monthly. The devices tested were Unity SpectraStar (n = 5) and MIRIS Human Milk Analyzer (n = 10). There are significant variations in accuracy and precision between different milk analyzers' fat, protein and lactose measurements. However, the accuracy of measurements can be improved by establishing individual correction algorithms. Repeated measurements are more robust when coming from a larger batch volume. Long term stability also varies between devices. The variations in measurements between devices are clinically significant and would impact both daily dietary prescriptions, and the outcomes of clinical studies assessing the effect of targeted adjustment of nutrient intake in preterm babies. This study shows that it is crucial to follow GCLP when using milk analyzers to ensure proper measurement of macronutrients, similar to what is required of other medical devices.

1 June 2017 in Clinics in Perinatology
Verified
Journal Article
Closed access
KMKera McNelis
Kera McNelis
Ting Ting FuTing Ting Fu
Ting Ting Fu
BPBrenda Poindexter
Brenda Poindexter

13 August 2019 in Nutrients
Verified
Journal Article
Open access
PDF file
Ting Ting FuTing Ting Fu
Ting Ting Fu
PSPaige Schroder
Paige Schroder
BPBrenda B. Poindexter
Brenda B. Poindexter
The macronutrient composition of target-pooled donor breast milk (DBM) (milk combined strategically to provide 20 kcal/oz) and growth patterns of preterm infants receiving it have not been characterized. Caloric target-pooled DBM samples were analyzed by near-infrared spectroscopy. Weekly growth velocities and anthropometric z-scores were calculated for the first 30 days and at 36 weeks corrected gestational age (CGA) for 69 very low birthweight (VLBW) infants receiving minimum one week of DBM. Samples contained mean 18.70 kcal/oz, 0.91 g/dL protein, 3.11 g/dL fat, 7.71 g/dL carbohydrate (n = 96), less than labeled values by 2.43 kcal/oz and 0.11 g/dL protein (p < 0.001). By week 3, growth reached 16.58 g/kg/day, 0.95 cm/week (length), and 1.01 cm/week (head circumference). Infants receiving 50% DBM had similar growth, but infants receiving >50% DBM were more likely to receive fortification >24 kcal/oz (83% vs. 51.9% in the <50% DBM group; p = 0.005). From birth to 36 weeks CGA (n = 60), there was a negative z-score change across all parameters with the greatest in length (−1.01). Thus, target-pooling does not meet recommended protein intake for VLBW infants. Infants fed target-pooled DBM still demonstrate a disproportionate negative change in length z-score over time.

20 August 2021 in Nutrients
Verified
Journal Article
Open access
PDF file
Ting Ting FuTing Ting Fu
Ting Ting Fu
HKHeather Kaplan
Heather Kaplan
TFTrayce Fields
Trayce Fields
AFAlonzo T. T. Folger
Alonzo T. T. Folger
KGKatelyn Gordon
Katelyn Gordon
BPBrenda B. Poindexter
Brenda B. Poindexter
Protein content is often inadequate in donor breast milk (DBM), resulting in poor growth. The use of protein-enriched target-pooled DBM (DBM+) has not been examined. We compared three cohorts of very low birth weight (VLBW) infants, born ≤ 1500 g: DBM cohort receiving > 1-week target-pooled DBM (20 kcal/oz), MBM cohort receiving ≤ 1-week DBM, and DBM+ cohort receiving > 1-week DBM+. Infants followed a standardized feeding regimen with additional fortification per clinical discretion. Growth velocities and z-scores were calculated for the first 4 weeks (n = 69 for DBM, 71 for MBM, 70 for DBM+) and at 36 weeks post-menstrual age (n = 58, 64, 59, respectively). In total, 60.8% MBM infants received fortification >24 kcal/oz in the first 30 days vs. 78.3% DBM and 77.1% DBM+. Adjusting for SGA, length velocity was greater with DBM+ than DBM in week 1. Average weight velocity and z-score change were improved with MBM compared to DBM and DBM+, but length z-score decreased similarly across all groups. Incidences of NEC and feeding intolerance were unchanged between eras. Thus, baseline protein enrichment appears safe in stable VLBW infants. Weight gain is greatest with MBM. Linear growth comparable to MBM is achievable with DBM+, though the overall length trajectory remains suboptimal.

26 May 2023 in Clinics in Perinatology
Verified
Journal Article
Closed access
Ting Ting FuTing Ting Fu
Ting Ting Fu
BPBrenda B. Poindexter
Brenda B. Poindexter

17 August 2024 in Pediatric Research
Verified
Journal Article
Open access
PDF file
Ting Ting FuTing Ting Fu
Ting Ting Fu
MAMaame Arhin
Maame Arhin
ASAshley T. Schulz
Ashley T. Schulz
AGAbigail Gardiner
Abigail Gardiner
SCStacie Chapman
Stacie Chapman
JKJae H. Kim
Jae H. Kim
Background: Use of standardized feeding protocols and donor breast milk (DBM) have been studied primarily in infants born 1500 g. Methods: In this retrospective pre-post-implementation cohort study, we evaluated a protocol for preterm infants born >1500 g that was implemented clinically to standardize feeding advancements at 30 mL/kg/day, with infants born <33 weeks eligible to receive DBM. We compared placement of peripherally inserted central catheters for parenteral nutrition, feeding tolerance, growth, and maternal milk provision in the 18 months before/after implementation. The association between DBM intake and growth was evaluated using multivariable linear regression. Results: We identified 133 and 148 eligible infants pre/post-implementation. Frequency of peripherally inserted central catheters and rate of maternal milk provision was not statistically different. While there was no difference in median days to full enteral volume, there was a narrower distribution post-implementation (p < 0.001). Growth was similar between eras, but each 10% increase in DBM was associated with 1.0 g/d decrease in weight velocity (p < 0.001). Conclusions: A feeding protocol for preterm infants >1500 g is associated with more consistent time to full enteral volume. Further investigation is needed to clarify DBM’s impact on growth in this population. Impact: Despite practice creep, no study has examined the use of standardized feeding protocols or pasteurized donor breast milk exclusively in infants >1500 g. A feeding protocol in this population may achieve full enteral feedings more consistently. With appropriate fortification, donor breast milk can support adequate growth in infants born >1500 g but warrants further study.