Naoko Yoshida

Dr. Naoko Yoshida

Kanazawa University

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2020 in Forensic Science International
Verified
Journal Article
Open access
TSTomoko Sanada
Tomoko Sanada
NYNaoko Yoshida
Naoko Yoshida
RMRyo Matsushita
Ryo Matsushita
KKKazuko Kimura
Kazuko Kimura
HTHirohito Tsuboi
Hirohito Tsuboi
The adverse health effects of falsified medicines for erectile dysfunction have been reported in Japan. We purchased tadalafil (Cialis) tablets online and assessed their authenticity and quality. Of the 45 samples we tested, nine were genuine, 23 were falsified, nine were unregistered/unlicensed samples, and the authenticity of four samples could not be ascertained. Observation of packaging and tablet size, weight, and color revealed differences between some genuine and falsified samples. All genuine samples contained the active pharmaceutical ingredient tadalafil at adequate quantities, while falsified samples contained sildenafil (Viagra). Some falsified samples contained insufficient quantities of tadalafil. All unregistered/unlicensed samples contained neither tadalafil nor sildenafil. Some falsified samples did not dissolve/disintegrate sufficiently. The status of most samples was detectable by Raman scattering and near-infrared spectroscopy. Restricting consumer access to falsified medicines can prevent undesirable health effects.

18 June 2013 in BMC Pharmacology and Toxicology
Verified
Journal Article
Open access
PDF file
MKMohiuddin Hussain Khan
Mohiuddin Hussain Khan
KHKirara Hatanaka
Kirara Hatanaka
TSTey Sovannarith
Tey Sovannarith
NNNam Nivanna
Nam Nivanna
LCLidia Cecilia Cadena Casas
Lidia Cecilia Cadena Casas
KKKazuko Kimura
Kazuko Kimura
The use of substandard and degraded medicines is a major public health problem in developing countries such as Cambodia. A collaborative study was conducted to evaluate the quality of amoxicillin–clavulanic acid preparations under tropical conditions in a developing country. Amoxicillin-clavulanic acid tablets were obtained from outlets in Cambodia. Packaging condition, printed information, and other sources of information were examined. The samples were tested for quantity, content uniformity, and dissolution. Authenticity was verified with manufacturers and regulatory authorities. A total of 59 samples were collected from 48 medicine outlets. Most (93.2%) of the samples were of foreign origin. Using predetermined acceptance criteria, 12 samples (20.3%) were non-compliant. Eight (13.6%), 10 (16.9%), and 20 (33.9%) samples failed quantity, content uniformity, and dissolution tests, respectively. Samples that violated our observational acceptance criteria were significantly more likely to fail the quality tests (Fisher’s exact test, p < 0.05). Improper packaging and storage conditions may reduce the quality of amoxicillin–clavulanic acid preparations at community pharmacies. Strict quality control measures are urgently needed to maintain the quality of amoxicillin–clavulanic acid in tropical countries.

1 January 2020 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Closed access
SZShu Zhu
Shu Zhu
NYNaoko Yoshida
Naoko Yoshida
KKKazuko Kimura
Kazuko Kimura
RMRyo Matsushita
Ryo Matsushita
HTHirohito Tsuboi
Hirohito Tsuboi

5 March 2014 in BMC Pharmacology and Toxicology
Verified
Journal Article
Open access
PDF file
NYNaoko Yoshida
Naoko Yoshida
MKMohiuddin Hussain Khan
Mohiuddin Hussain Khan
HTHitomi Tabata
Hitomi Tabata
EDEav Dararath
Eav Dararath
TSTey Sovannarith
Tey Sovannarith
KKKazuko Kimura
Kazuko Kimura
Access to good-quality medicines in many countries is largely hindered by the rampant circulation of spurious/falsely labeled/falsified/counterfeit (SFFC) and substandard medicines. In 2006, the Ministry of Health of Cambodia, in collaboration with Kanazawa University, Japan, initiated a project to combat SFFC medicines.

24 April 2012 in Pharmacoepidemiology and Drug Safety
Verified
Journal Article
Closed access
PDF file
KHKatsuhito Hori
Katsuhito Hori
KYKasumi Yamakawa
Kasumi Yamakawa
NYNaoko Yoshida
Naoko Yoshida
KOKazunori Ohnishi
Kazunori Ohnishi
JKJunichi Kawakami
Junichi Kawakami

6 June 2018 in The American Journal of Tropical Medicine and Hygiene
Verified
Journal Article
Closed access
TKTomoko Kakio
Tomoko Kakio
HNHitomi Nagase
Hitomi Nagase
TTTakashi Takaoka
Takashi Takaoka
NYNaoko Yoshida
Naoko Yoshida
JHJunichi Hirakawa
Junichi Hirakawa
KKKazuko Kimura
Kazuko Kimura
The World Health Organization has warned that substandard and falsified medical products (SFs) can harm patients and fail to treat the diseases for which they were intended, and they affect every region of the world, leading to loss of confidence in medicines, health-care providers, and health systems. Therefore, development of analytical procedures to detect SFs is extremely important. In this study, we investigated the quality of pharmaceutical tablets containing the antihypertensive candesartan cilexetil, collected in China, Indonesia, Japan, and Myanmar, using the Japanese pharmacopeial analytical procedures for quality control, together with principal component analysis (PCA) of Raman spectrum obtained with handheld Raman spectrometer. Some samples showed delayed dissolution and failed to meet the pharmacopeial specification, whereas others failed the assay test. These products appeared to be substandard. Principal component analysis showed that all Raman spectra could be explained in terms of two components: the amount of the active pharmaceutical ingredient and the kinds of excipients. Principal component analysis score plot indicated one substandard, and the falsified tablets have similar principal components in Raman spectra, in contrast to authentic products. The locations of samples within the PCA score plot varied according to the source country, suggesting that manufacturers in different countries use different excipients. Our results indicate that the handheld Raman device will be useful for detection of SFs in the field. Principal component analysis of that Raman data clarify the difference in chemical properties between good quality products and SFs that circulate in the Asian market.