Gabriele Papini

Dr. Gabriele Papini

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 August 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
GPGabriele Papini
Gabriele Papini
PFPedro Fonseca
Pedro Fonseca
MGMerel M. van Gilst
Merel M. van Gilst
JBJan W. M. Bergmans
Jan W. M. Bergmans
RVRik Vullings
Rik Vullings
SOSebastiaan Overeem
Sebastiaan Overeem
A large part of the worldwide population suffers from obstructive sleep apnea (OSA), a disorder impairing the restorative function of sleep and constituting a risk factor for several cardiovascular pathologies. The standard diagnostic metric to define OSA is the apnea–hypopnea index (AHI), typically obtained by manually annotating polysomnographic recordings. However, this clinical procedure cannot be employed for screening and for long-term monitoring of OSA due to its obtrusiveness and cost. Here, we propose an automatic unobtrusive AHI estimation method fully based on wrist-worn reflective photoplethysmography (rPPG), employing a deep learning model exploiting cardiorespiratory and sleep information extracted from the rPPG signal trained with 250 recordings. We tested our method with an independent set of 188 heterogeneously disordered clinical recordings and we found it estimates the AHI with a good agreement to the gold standard polysomnography reference (correlation = 0.61, estimation error = 3±10 events/h). The estimated AHI was shown to reliably assess OSA severity (weighted Cohen’s kappa = 0.51) and screen for OSA (ROC–AUC = 0.84/0.86/0.85 for mild/moderate/severe OSA). These findings suggest that wrist-worn rPPG measurements that can be implemented in wearables such as smartwatches, have the potential to complement standard OSA diagnostic techniques by allowing unobtrusive sleep and respiratory monitoring.

31 May 2018 in BMC Sports Science, Medicine and Rehabilitation
Verified
Journal Article
Open access
PDF file
Francesco SartorFrancesco Sartor
Francesco Sartor
JGJos Gelissen
Jos Gelissen
RDRalph van Dinther
Ralph van Dinther
DRDavid Roovers
David Roovers
GPGabriele Papini
Gabriele Papini
GCGiuseppe Coppola
Giuseppe Coppola
The need for unobtrusive HR (heart rate) monitoring has led to the development of a new generation of strapless HR monitors. The aim of this study was to determine whether such an unobtrusive, wrist-worn optical HR monitor (OHRM) could be equivalent and therefore a valid alternative to a traditional chest strap during a broad range of activities in a heterogeneous healthy population and coronary artery disease (CAD) patients. One hundred ninety-nine healthy volunteers, 84 males and 115 females, including 35 overweight-obese subjects, 53 pregnant women, and 20 CAD patients were tested in the present study. Second-by-second HR measured by the OHRM was concurrently evaluated against an ECG-based chest strap monitor during a broad range of activities (i.e., walking, running, cycling, gym, household, and sedentary activities). Data coverage, percentage of time the OHRM provides a HR not larger than 10 bpm from the reference, went from a minimum of 92% of the time in the least periodic activity (i.e., gym), to 95% during the most intense activity (i.e., running), and to a maximum of 98% for sedentary activities. The limits of agreement of the difference between the OHRM and the chest strap HR were within the range of ±15 bpm. The OHRM showed a concordance correlation coefficient of 0.98. Overall, the mean absolute error was not larger than 3 bpm, which can be considered clinically acceptable for a number of applications. A similar performance was found for CAD (94.2% coverage, 2.4 bpm error), but the small sample size does not allow any quantitative comparison. Heart rate measured by OHRM at the wrist and ECG-based HR measured via a traditional chest strap are acceptably close in a broad range of activities in a heterogeneous, healthy population, and showed initial promising results also in CAD patients.

2 July 2018 in Journal of Medical Internet Research
Verified
Journal Article
Open access
Francesco SartorFrancesco Sartor
Francesco Sartor
GPGabriele Papini
Gabriele Papini
LCLieke Cox
Lieke Cox
JCJohn George Franklin Cleland
John George Franklin Cleland
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet

13 December 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Francesco SartorFrancesco Sartor
Francesco Sartor
Matteo BonatoMatteo Bonato
Matteo Bonato
GPGabriele Papini
Gabriele Papini
ABAndrea Bosio
Andrea Bosio
RMRahil A. Mohammed
Rahil A. Mohammed
HKHans-Peter Kubis
Hans-Peter Kubis
Cardio-respiratory fitness (CRF) is a widespread essential indicator in Sports Science as well as in Sports Medicine. This study aimed to develop and validate a prediction model for CRF based on a 45 second self-test, which can be conducted anywhere. Criterion validity, test re-test study was set up to accomplish our objectives. Data from 81 healthy volunteers (age: 29 ± 8 years, BMI: 24.0 ± 2.9), 18 of whom females, were used to validate this test against gold standard. Nineteen volunteers repeated this test twice in order to evaluate its repeatability. CRF estimation models were developed using heart rate (HR) features extracted from the resting, exercise, and the recovery phase. The most predictive HR feature was the intercept of the linear equation fitting the HR values during the recovery phase normalized for the height2 (r2 = 0.30). The Ruffier-Dickson Index (RDI), which was originally developed for this squat test, showed a negative significant correlation with CRF (r = -0.40), but explained only 15% of the variability in CRF. A multivariate model based on RDI and sex, age and height increased the explained variability up to 53% with a cross validation (CV) error of 0.532 L ∙ min-1 and substantial repeatability (ICC = 0.91). The best predictive multivariate model made use of the linear intercept of HR at the beginning of the recovery normalized for height2 and age2; this had an adjusted r2 = 0. 59, a CV error of 0.495 L·min-1 and substantial repeatability (ICC = 0.93). It also had a higher agreement in classifying CRF levels (κ = 0.42) than RDI-based model (κ = 0.29). In conclusion, this simple 45 s self-test can be used to estimate and classify CRF in healthy individuals with moderate accuracy and large repeatability when HR recovery features are included.

1 November 2018 in Physiological Measurement
Verified
Journal Article
Closed access
PDF file
GPGabriele Papini
Gabriele Papini
PFPedro Fonseca
Pedro Fonseca
LELinda M Eerikäinen
Linda M Eerikäinen
SOSebastiaan Overeem
Sebastiaan Overeem
JBJan W M Bergmans
Jan W M Bergmans
RVRik Vullings
Rik Vullings
Objective : Wrist-worn photoplethysmography (PPG) can enable free-living physiological monitoring of people during diverse activities, ranging from sleep to physical exercise. In many applications, it is important to remove the pulses not related to sinus rhythm beats from the PPG signal before using it as a cardiovascular descriptor. In this manuscript, we propose an algorithm to assess the morphology of the PPG signal in order to reject non-sinus rhythm pulses, such as artefacts or pulses related to arrhythmic beats. Approach : The algorithm segments the PPG signal into individual pulses and dynamically evaluates their morphological likelihood of being normal sinus rhythm pulses via a template-matching approach that accounts for the physiological variability of the signal. The normal sinus rhythm likelihood of each pulse is expressed as a quality index that can be employed to reject artefacts and pulses related to arrhythmic beats. Main results : Thresholding the pulse quality index enables near-perfect detection of normal sinus rhythm beats by rejecting most of the non-sinus rhythm pulses (positive predictive value 98%–99%), both in healthy subjects and arrhythmic patients. The rejection of arrhythmic beats is almost complete (sensitivity to arrhythmic beats 7%–3%), while the sensitivity to sinus rhythm beats is not compromised (96%–91%). Significance : The developed algorithm consistently detects normal sinus rhythm beats in a PPG signal by rejecting artefacts and, as a first of its kind, arrhythmic beats. This increases the reliability in the extraction of features which are adversely influenced by the presence of non-sinus pulses, whether related to inter-beat intervals or to pulse morphology, from wrist-worn PPG signals recorded in free-living conditions.

1 July 2017
Verified
Conference Paper
Closed access
GPGabriele Papini
Gabriele Papini
PFPedro Fonseca
Pedro Fonseca
XAXavier L. Aubert
Xavier L. Aubert
SOSebastiaan Overeem
Sebastiaan Overeem
JBJan W.M. Bergmans
Jan W.M. Bergmans
RVRik Vullings
Rik Vullings
Photoplethysmography (PPG) is one of the key technologies for unobtrusive physiological monitoring, with ongoing attempts to use it in several medical fields, ranging from night to night sleep analysis to continuous cardiac arrhythmia monitoring. However, the PPG signals are susceptible to be corrupted by noise and artifacts, caused, e.g., by limb or sensor movement. These artifacts affect the morphology of PPG waves and prevent the accurate detection and localization of beats and subsequent cardiovascular feature extraction. In this paper a new algorithm for beat detection and pulse quality assessment is described. The algorithm segments the PPG signal in pulses, localizes each beat and grades each segment with a quality index. The obtained index results from a comparison between each pulse and a template derived from the surrounding pulses, by mean of dynamic time warping barycenter averaging. The quality index is used to discard corrupted pulse beats. The algorithm is evaluated by comparing the detected beats with annotated PPG signals and the results are published over the same data. The described method achieves an improved sensitivity and a higher predictive value.