Brett Levine

Dr. Brett Levine


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2006 in Biomaterials
Verified
Journal Article
Closed access
BLBrett Levine
Brett Levine
SSScott Sporer
Scott Sporer
RPRobert A. Poggie
Robert A. Poggie
CVCraig J. Della Valle
Craig J. Della Valle
JJJoshua J. Jacobs
Joshua J. Jacobs

19 August 2008 in Advanced Engineering Materials
Verified
Journal Article
Closed access
PDF file
BLBrett Levine
Brett Levine

25 April 2023 in Arthroplasty Today
Verified
Journal Article
Open access
VHVishal Hegde
Vishal Hegde
JSJeffrey B. Stambough
Jeffrey B. Stambough
BLBrett Levine
Brett Levine
BSBryan D. Springer
Bryan D. Springer
The 2022 American Joint Replacement Registry Annual Report includes data from over 2.8 million hip and knee procedures from over 1,250 institutions that encompass all 50 states and the District of Columbia. This represents a cumulative registered procedural volume growth of 14% compared to the previous year, making the American Joint Replacement Registry the largest arthroplasty registry by volume in the world.

29 January 2022 in Arthroplasty Today
Verified
Journal Article
Open access
ASAhmed Siddiqi
Ahmed Siddiqi
BLBrett Levine
Brett Levine
BSBryan D. Springer
Bryan D. Springer

29 February 2024 in Arthroplasty Today
Verified
Journal Article
Open access
SRSean P. Ryan
Sean P. Ryan
JSJeffrey B. Stambough
Jeffrey B. Stambough
JHJames I. Huddleston
James I. Huddleston
BLBrett Levine
Brett Levine
The 2023 report represents a full decade of published annual reports of the American Joint Replacement Registry (AJRR). The number of cases being captured continues to rapidly grow, as are over 3.2 million patients included in AJRR. Matched-pair primary and revision data is more robust with 10-year survivorship being available. Similarly, implant-specific survivorship has been included for common implants being used in the United States. The data mined from the AJRR have led to numerous publications and presentations. Numerous trends have emerged, and others have been reinforced with the most recent data. The authors encourage readers to more thoroughly review the full report at the following link: https://www.aaos.org/registries/publications/ajrr-annual-report/.

2 November 2010 in Orthopedics
Verified
Journal Article
Closed access
BLBrett Levine
Brett Levine
DFDavid Fabi
David Fabi
CDCarl Deirmengian
Carl Deirmengian
The use of digital radiography is becoming more prevalent in orthopedics. This transition impacts the ability to preoperatively plan for implants in total hip arthroplasty (THA) and total knee arthroplasty (TKA). This article reports on the clinical success of digital templating using the Advanced Case Plan (Stryker Imaging, Flower Mound, Texas) system in primary THA and TKA. Digital radiographs of 269 consecutive patients undergoing primary THA (93 cases) or TKA (176 cases) were templated using the Advanced Case Plan digital software package. A 25.4-mm metallic sphere was used as a calibrating marker. Anteroposterior hip and lateral knee radiographs were digitally templated preoperatively and compared to the actual size of the implants at the time of surgery. The accuracy of calibrating images using the metallic sphere was validated by measuring the diameter of femoral heads on 25 postoperative hip radiographs. Digital templating was accurate in predicting the correct implant size in 58.5% of THAs and 66% of TKAs. In 93% of THAs and 98.5% of TKAs, preoperative templating was within 1 size of the final implant. There were no cases in which the predicted implant size varied from the final components by >2 sizes. Calibrating the image using the metallic sphere marker was found to be highly accurate, predicting the correct femoral head size within 1.5 mm in all 25 cases (7 hemiarthroplasties and 18 THAs). Digital templating is an effective means for predicting the size of THA and TKA components, thus remaining a viable option as we transition into the modern era of digital radiography. Future studies will evaluate interobserver reliability and the impact of level of training on templating accuracy.