Di Shi

Dr. Di Shi

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 February 2024 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
YSYixin Shao
Yixin Shao
DSDi Shi
Di Shi
YFYanggang Feng
Yanggang Feng
WZWuxiang Zhang
Wuxiang Zhang
XDXilun Ding
Xilun Ding
This article presents a novel variable stiffness actuator (VSA) capable of wide-range stiffness regulation and has a compact structure. A cam-circular beam mechanism is proposed in the design of variable stiffness mechanisms. By adjusting the pivot position, the stiffness of the actuator can be regulated from a minimum value to near infinite. Different from the VSAs, which use rotation-to-translation converting mechanisms in the design of stiffness regulation mechanisms, the stiffness regulation of the proposed actuator is achieved by simply rotating the pivot shaft with the help of circular beams. This contributes to the improvement of the compactness and power density of the actuator. Moreover, the transmission ratio between the beam deformation and the joint deflection is determined by the cam mechanism, then the stiffness profile and range of the stiffness can be customized. The control of the actuator is realized by using a proxy-based control method, and an adaptive law is proposed to adjust the control parameter and the joint mechanical stiffness online. Then, significant force compliance is achieved at the control and mechanical level, which guarantees interaction safety when unexpected interruptions occur. The prototype of the proposed actuator is developed and experiments are carried out, which verify the stiffness regulation capability of the actuator and the control performance.

27 May 2022 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
DSDi Shi
Di Shi
WZWei Zhang
Wei Zhang
LWLiduan Wang
Liduan Wang
WZWuxiang Zhang
Wuxiang Zhang
YFYanggang Feng
Yanggang Feng
XDXilun Ding
Xilun Ding
A serial–parallel lower limb rehabilitation exoskeleton can achieve a kinematic function similar to that of the human lower limb. Based on this bionic structure, joint-angle coordination is needed for model-based control. Because the kinematics of the parallel mechanism is difficult to solve, real-time attitude control of the task space cannot be realized. Moreover, owing to structural errors and parameter uncertainty, accurate modeling cannot be realized, which causes difficulties in system control. Therefore, based on existing modeling methods, adaptive control of a serial–parallel lower limb rehabilitation exoskeleton is proposed. The sensor of the parallel mechanism can realize accurate perception of the attitude, and the controller is designed to solve the control problem of the task space of the parallel component. A radial basis function neural network adaptive controller is used to compensate for the uncertainty and external disturbance of the model. Experiments were conducted to verify the effectiveness of the dynamic modeling and control system.

15 December 2021 in Sensors
Verified
Journal Article
Open access
PDF file
YWYapeng Wang
Yapeng Wang
WZWei Zhang
Wei Zhang
DSDi Shi
Di Shi
YGYunhai Geng
Yunhai Geng
A knee exoskeleton with an adaptive instantaneous rotation center and impact absorption is used for rehabilitation. Due to the human knee joint’s special physiological structure and motion characteristics, the exoskeleton mechanism needs to be designed for both static and dynamic aspects. Therefore, a novel knee exoskeleton mechanism was designed. To adapt to the rotation center of the knee joint, a mechanism with cross-configuration was designed according to the equivalent degree of freedom and the stiffness of the springs was calculated by its combination with gait motion, so that the average force of the human body was minimized. A dynamic model of the exoskeleton was established. To overcome the uncertainty in the parameters of the human and robotic limbs, an adaptive controller was designed and a Lyapunov stability analysis was conducted to verify the system. A simulation was conducted and experimental results show that the tracking error of the knee joint angle between the actual and desired trajectory was within the range of −1 to 1 degree and indicate the effectiveness of the controller.

24 August 2023 in IEEE Transactions on Automation Science and Engineering
Verified
Journal Article
Closed access
YSYixin Shao
Yixin Shao
DSDi Shi
Di Shi
WZWuxiang Zhang
Wuxiang Zhang
XDXilun Ding
Xilun Ding
This paper presents a novel variable stiffness actuator (VSA) based on a cam-leaf spring mechanism, namely, CLSM-VSA. A sophisticatedly designed cam is used to regulate the transmission ratio between the deformation of the leaf spring and the deflection angle of the VSA, such that the stiffness profile of the actuator can be customized (linear, softening, or hardening). This property is meaningful for specific applications, e.g., VSAs with softening stiffness profiles help reduce the collision force, which is verified by our experiments. Moreover, the stiffness of the proposed actuator can also be continuously regulated by adjusting the location of the pivots that are in contact with the leaf springs. In this case, the stiffness not only can be changed passively with fast speed when the applied torque changes, but can also be regulated actively for different circumstances. Compared to other designs with similar output torque or power, the CLSM-VSA has the merits of compactness, low-power cost stiffness regulation, and high-power density. Additionally, the CLSM-VSA also features wide-range stiffness regulation, and the ratio between the maximum and minimum stiffness is approximately 20. The stiffness characteristics, control performances, and stiffness regulation efficiency of the proposed design are experimentally evaluated. Note to Practitioners —The VSA is a class of compliant actuators that can perform joint positioning and mechanical stiffness regulation, and its inherent compliance makes it suitable for robotics that have physical interaction with environments. In the design of VSAs, compactness and the capability of stiffness regulation are always the most critical features. This paper proposes a novel VSA based on a cam-leaf spring mechanism, which can derive customized stiffness profiles for specific requirements, e.g., softening stiffness for enhancing collision safety. Additionally, we can also actively regulate the actuator stiffness by using a stiffness regulation motor over a wide range and with low-power cost, which makes the actuator suitable for different circumstances. The use of cams and parallelly assembled leaf springs results in a compact design, and the power density ranks high among the designs in the literature. Moreover, the stiffness ranges can be changed by replacing cams, which does not affect the overall dimension of the actuator and benefitsmodularization. In the future, we will focus on the application oftheproposed VSA and further explore the advantages of VSAs with adjustable nonlinear stiffness properties.

1 January 2020 in Biology Open
Verified
Journal Article
Open access
PDF file
DSDi Shi
Di Shi
WZWuxiang Zhang
Wuxiang Zhang
XDXilun Ding
Xilun Ding
LSLei Sun
Lei Sun
For robot-assisted rehabilitation and assessment of the patients with motor dysfunction, the parametric generation of their normal gait as the input for the robot is essential to match with the features of the patient to a greater extent. In addition, the gait needs to be in three-dimensional space, which meets the physiological structure of the human better, rather than only in sagittal plane. Thus, a method for the parametric generation of three-dimensional gait based on the influence of the motion parameters (MPs) and structure parameters (SPs) is presented. First, the three-dimensional gait kinematic of participants is collected, and trajectories of ankle joint angle and ankle center position are calculated. Second, for the trajectories, the gait features are extracted including gait events indicating the physiological features of the walking gait in additional to extremes indicating the geometrical features of the trajectories. Third, regression models are derived after using leave-one-out cross-validation for model optimization. Finally, cubic splines are fitted between the predicted gait features to generate the trajectories for a full gait cycle. It is inferred the generated curves well match the measured curves. The method presented herein will gives an important reference for the research of the lower limb rehabilitation robots.

2 May 2022 in Frontiers in Robotics and AI
Verified
Journal Article
Open access
LMLufan Mo
Lufan Mo
PFPengbo Feng
Pengbo Feng
YSYixin Shao
Yixin Shao
DSDi Shi
Di Shi
LJLinhang Ju
Linhang Ju
XDXilun Ding
Xilun Ding
Lower limb exoskeletons are widely used for rehabilitation training of patients suffering from neurological disorders. To improve the human–robot interaction performance, series elastic actuators (SEAs) with low output impedance have been developed. However, the adaptability and control performance are limited by the constant spring stiffness used in current SEAs. In this study, a novel load-adaptive variable stiffness actuator (LaVSA) is used to design an ankle exoskeleton. To overcome the problems of the LaVSA with a larger mechanical gap and more complex dynamic model, a sliding mode controller based on a disturbance observer is proposed. During the interaction process, due to the passive joints at the load side of the ankle exoskeleton, the dynamic parameters on the load side of the ankle exoskeleton will change continuously. To avoid this problem, the designed controller treats it and the model error as a disturbance and observes it with the disturbance observer (DOB) in real time. The first-order derivative of the disturbance set is treated as a bounded value. Subsequently, the parameter adaptive law is used to find the upper bound of the observation error and make corresponding compensation in the control law. On these bases, a sliding mode controller based on a disturbance observer is designed, and Lyapunov stability analysis is given. Finally, simulation and experimental verification are performed. The wearing experiment shows that the resistance torque suffered by humans under human–robot interaction is lower than 120 Nmm, which confirms that the controller can realize zero-impedance control of the designed ankle exoskeleton.