Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
22 November 2017 in IEEE Transactions on Terahertz Science and Technology
Reflection-mode terahertz (THz) imaging of corneal tissue water content (CTWC) is a proposed method for early accurate detection and study of corneal diseases. Despite promising results from ex vivo and in vivo cornea studies, interpretation of the reflectivity data is confounded by the contact between corneal tissue and dielectric windows used to flatten the imaging field. Herein, we present an optical design for noncontact THz imaging of cornea. A beam-scanning methodology performs angular normal incidence sweeps of a focused beam over the corneal surface while keeping the source, detector, and patient stationary. A quasi-optical analysis method is developed to analyze the theoretical resolution and imaging field intensity profile. These results are compared to the electric field distribution computed with a physical optics analysis code. Imaging experiments validate the optical theories behind the design and suggest that quasi-optical methods are sufficient for designing of THz corneal imaging systems. Successful imaging operations support the feasibility of noncontact in vivo imaging. We believe that this optical system design will enable the first, clinically relevant, in vivo exploration of CTWC using THz technology.
Absolute thickness and free water content gradients in gelatin-based corneal phantoms with physiologically accurate radii of curvature, and aqueous backing were extracted via coherent submillimeter wave reflectometry at 220 330 GHz. Fourier-domain based calibration methods, utilizing temporal and spatial gating, were developed and yielded peak-to-peak amplitude and phase clutter of 10-3 and 0.1, respectively for signal to noise ratios between 40 dB and 50 dB. Twelve phantoms were fabricated. Calibration methods enabled quantification of target sphericity that strongly correlated with optical coherence tomography-based sphericity metrics via image segmentation. Extracted free water volume fraction varied less than 5 % in the 5 phantoms whose fabrication yielded the most spherical geometry. Submillimeter wave-based thickness accuracy was better than 111 m (~/9) with average of 65 m (~/17) and standard deviation of 44 m (~/25) for phantoms with physiologically relevant geometry. Monte Carlo simulations of measurement noise and uncertainty limits agree with experimental data analysis and indicates a lower thickness accuracy limit of 33 m, and water content sensitivities of 0.5 % and 11.8 % for the anterior and posterior segments respectively. Numerical analysis suggests measurement fidelity was SNR limited and identified optical path length ambiguities within the cornea where a continuum of thickness/water gradient pairs produce statistically insignificant differences in complex reflection coefficient for finite SNR. This is the first known submillimeter-wave measurement technique able to extract both the thickness and water content gradients from a soft-tissue phantom, with a water backing, without the need for ancillary measurements.
We report that an ErAs quantum-dot array in a GaAs matrix under 1550 nm pulsed excitation produces cooperative spontaneous emission—Dicke superradiance—in the terahertz frequency region at room temperature. Two key points pertain to the experimental evidence: (i) the pulsed THz emission power is much greater than the continuous wave (CW) photomixing power; and (ii) the ultrafast time-domain waveform displays ringing cycles. A record of ~117 μW pulsed THz power was obtained, with a 1550 nm-to-THz power conversion efficiency of ~0.2%.
10 June 2021 in IEEE Transactions on Terahertz Science and Technology
This paper presents measurements of the permittivity of gelatin hydrogels between 220 and 330 GHz. Hydrated gelatin was treated as a binary mixture of free water and a compound consisting of water bound to collagen. Submillimeter-wave reflectometry was used to estimate the hydrated gelatin permittivity, hydrated gelatin density, and free-water volume fraction in phantoms composed of 62, 67, 72, and 77% water by weight. A hydrated dry/wet density ratio of 0.335 was validated with optical-coherence tomography. A constant non-freezing bound-water mass of 0.6 g/g was observed and confirmed with differential-scanning calorimetry. Good agreement between results from different modalities supports the dielectric spectroscopy methods and data analysis. Depending on the hydrodynamics at the sample/air interface, measurements indicate a bound-water compound permittivity of 3.77 - j2.52 to 3.95 - j2.49 contrasting the pure-water average permittivity of 5.16 j5.63. The loss related to bound water was much higher than anticipated and characterization will help reduce uncertainty in measurements of gelatin hydrogel-based tissue phantoms; particularly corneal phantoms where adjacent free water creates complex hydration gradients. This is the first known, submillimeter-wave, frequency domain measurement of complex permittivity of the bound-water component in solid, proteinaceous matter.