Hendrik Neubert

Dr. Hendrik Neubert

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 December 2012 in Analytical Chemistry
Verified
Journal Article
Closed access
HNHendrik Neubert
Hendrik Neubert
DMDavid Muirhead
David Muirhead
MKMusarat Kabir
Musarat Kabir
CGChris Grace
Chris Grace
ACAdriaan Cleton
Adriaan Cleton
RARosalin Arends
Rosalin Arends

16 April 2008 in Journal of Proteome Research
Verified
Journal Article
Closed access
HNHendrik Neubert
Hendrik Neubert
TBTimothy P. Bonnert
Timothy P. Bonnert
KRKlaus Rumpel
Klaus Rumpel
BHBrandon T. Hunt
Brandon T. Hunt
EHErnst S. Henle
Ernst S. Henle
IJIan T. James
Ian T. James

1 September 2010 in Clinical Chemistry
Verified
Journal Article
Closed access
PDF file
HNHendrik Neubert
Hendrik Neubert
JGJeremy Gale
Jeremy Gale
DMDavid Muirhead
David Muirhead
BACKGROUND: Detection limit challenges associated with measuring low-abundance protein biomarkers can be addressed with hybrid immunoaffinity–mass spectrometric assays, such as antipeptide antibody capture followed by liquid chromatography/tandem mass spectrometry (LC-MS/MS). Popular assay formats use magnetic bead–based immunoaffinity enrichment and nanoflow LC-MS/MS or high-flow immunoaffinity chromatography coupled online to conventional LC-MS/MS. As a proof of principle, we describe a novel online immunoaffinity LC-MS/MS configuration that combines high-flow peptide immunoaffinity enrichment and nanoflow LC-MS/MS. METHODS: We configured and validated an assay for the measurement of total pepsin/pepsinogen from human saliva that uses a pepsinogen standard. Saliva was heat-inactivated to quench residual enzymatic activity and then digested with endoproteinase AspN. Online immunoaffinity enrichment using an antipeptide antibody directed against the pepsin C-terminal sequence, DRANNQVGLAPVA, was linked to nanoflow liquid chromatography and selected reaction monitoring mass spectrometry. We used the assay to measure pepsin/pepsinogen concentrations in human saliva from presumed healthy volunteers. RESULTS: Heat inactivation at 100 °C for 25 min stabilized the target peptide. The final assay had <15% interassay relative error and <15% interassay CV across a range of 4.08–2980 pmol/L human pepsinogen (0.165–120 μg/L). Low but quantifiable signals were observed in some samples from presumed normal healthy volunteers ranging from 4.3 to 16.6 pmol/L (0.17–0.67 μg/L) total salivary pepsin/pepsinogen. CONCLUSIONS: This assay approach provides a high-sensitivity platform for protein bioanalysis in the low picomolar range. It bears the potential to deliver additional data on the salivary occurrence of pepsin/pepsinogen with greater confidence than previously.

15 August 2008 in Analytical Chemistry
Verified
Journal Article
Closed access
HNHendrik Neubert
Hendrik Neubert
CGChristopher Grace
Christopher Grace
KRKlaus Rumpel
Klaus Rumpel
IJIan James
Ian James

15 August 2019 in Biomolecules
Verified
Journal Article
Open access
PDF file
YFYAO-YUN FAN
YAO-YUN FAN
VFVahid Farrokhi
Vahid Farrokhi
TCTeresa Caiazzo
Teresa Caiazzo
MWMengmeng Wang
Mengmeng Wang
DODenise M. O’hara
Denise M. O’hara
HNHendrik Neubert
Hendrik Neubert
System-wide quantitative characterization of human neonatal Fc receptor (FcRn) properties is critical for understanding and predicting human PK (pharmacokinetics) as well as the distribution of mAbs and Fc-fusion proteins using PBPK (physiologically-based pharmacokinetic) modeling. To this end, tissue-specific FcRn expression and half-life are important model inputs. Herein, human FcRn tissue expression was measured by peptide immunoaffinity chromatography coupled with high-resolution mass spectrometry. FcRn concentrations across 14 human tissues ranged from low to 230 pmol per gram of tissue. Furthermore, the FcRn half-life was determined to be 11.1 h from a human stable isotope labelled leucine pulse labeling experiment. The spatial and temporal quantitative human FcRn data now promise to enable a refined PBPK model with improved accuracy of human PK predictions for Fc-containing biotherapeutics.

23 November 2012 in Bioanalysis
Verified
Journal Article
Closed access
HNHendrik Neubert
Hendrik Neubert
SFScott Fountain
Scott Fountain
LKLindsay King
Lindsay King
TCTracey Clark
Tracey Clark
YWYan Weng
Yan Weng
EFEric Fluhler
Eric Fluhler
Contemporary drug discovery leverages quantitative modeling and simulation with increasing emphasis, both to gain deeper knowledge of drug targets and mechanisms as well as improve predictions between preclinical models and clinical applications, such as first-in-human dose projections. Proliferation of novel biotherapeutic modalities increases the need for applied PK/PD modeling as a quantitative tool to advance new therapies. Of particular relevance is the understanding of exposure, target binding and associated pharmacology at the target site of interest. Bioanalytical methods are key to informing PK/PD models and require assessment of both PK and PD end points. Where targets are sequestered in tissues (noncirculating), the ability to quantitatively measure drug or biomarker in tissue compartments becomes particularly important. This perspective provides an overview of contemporary applications of quantitative bioanalysis in tissue compartments as applied to PK and PD assessments associated with novel biotherapeutics. Case studies and key references are provided.