In this study, tests were carried out on a brushless permanent magnet DC motor with different winding configurations. Three configurations were compared: star, delta and combined star–delta. A mathematical model was constructed for the motor, taking into account the different winding configurations. An analysis of the operation of the motor in the different configurations was performed, based on numerical calculations. The use of different winding configurations affects the properties of the motor. This is significant in the case of the occurrence of various fault states. Based on numerical calculations, an analysis of an open-circuit fault in one of the phases of the motor was performed. Fast Fourier Transform—FFT analysis of the artificial neutral-point voltage was used for the detection of fault states. The results were verified by tests carried out under laboratory conditions. It was shown that the winding configuration has an impact on the behaviour of the motor in the case of an open circuit in one of the phases. The classical star configuration is the worst of the possible arrangements. The most favourable in this respect is the delta configuration. In the case of the combined star–delta configuration, the consequences of the fault depend on the location of the open circuit.
1 December 2016 in Archives of Electrical Engineering
In the paper, the modified (compared to the classical asymmetric half-bridge) converter for a switched reluctance machine with an asymmetric rotor magnetic circuit was analysed. An analysis for two various structures of switched reluctance motors was conducted. The rotor shaping was used to obtain required start-up torque or/and to obtain less electromagnetic torque ripple. The discussed converter gives a possibility to turn a phase off much later while reduced time of a current flows in a negative slope of inductance. The results of the research in the form of waveforms of currents, voltages and electromagnetic torque were presented. Conclusions were formulated concerning the comparison of the characteristics of SRM supplied by the classic converter and by the one supplied by the analysed converter.
This paper presents a description and the results of simulations and laboratory tests of proposed methods for dependent torque control in a Switched Reluctance Motor (SRM). The proposed methods are based on Dependent Torque Motor Control (Rising Slope), DTMC(RC), and Dependent Torque Motor Control (Falling Slope), DTMC(FC). The results of these studies were compared with those on the Classical Torque Motor Control (CTMC) method. Studies were conducted for each of the analyzed control methods by determining the efficiency of the drive and the RMS of the source current and analyzing the vibrations generated for each of the control methods. The harmonics of the phase currents, which caused an increase in the level of vibrations generated, were determined. The usefulness of the proposed methods for controlling SRMs was assessed based on simulations and experiments. Additionally, the natural frequencies of the stator of the tested SRM were determined by a simulation using the Ansys Maxwell suite. The levels of vibration acceleration generated by the SRM were compared for the considered control methods.
This paper analyses the condition of a partial short-circuit in a brushless permanent magnet motor. Additionally, the problem was analysed for three stator winding configurations: star, delta and star-delta connection. The paper presents an original mathematical model allowing a winding configurations to be analysed. What is more, the said mathematical model allows taking account of the partial short-circuit condition. Frequency analysis (Fast Fourier Transform—FFT) of the artificial neutral point voltage was proposed for the purpose of detecting the partial short-circuit condition. It was demonstrated that a partial short-circuit causes a marked increase in the diagnostic frequencies of the voltage signal. The proposed brushless permanent magnet motor diagnostic method is able to detect the fault regardless of the stator winding configuration type.
Achieving increased fault tolerance in an electric motor requires decisions to be made about the type and specifications of the motor machine and its appropriate design. Depending on the type of motor, there are generally three ways to achieve an increased resistance of the drive system to tolerate resulting faults. The simplest way is to select the right motor and design it appropriately. Switched reluctance motors (SRMs) have a high tolerance for internal faults (in the motor windings). Failure tolerance can be improved by using parallel paths. The SRM 24/16 solution has been proposed, which allows for operation with four parallel paths. In this paper, a mathematical model designed to analyse the problem under consideration is provided. Based on numerical calculations, the influence of typical faults (open and partial short circuit in one of the paths) on the electromagnetic torque generated as well as its ripple and (source and phase) currents were determined. The higher harmonics of the source current (diagnostic signal) were determined. Laboratory tests were performed to verify the various configurations for the symmetric and emergency operating states. The feasibility of SRM correct operation monitoring was determined from an FFT analysis of the source current.
In this study, a permanent magnet brushless direct current machine with multi-phase windings is proposed for critical drive systems. We have named the solution, which has four-stator winding, a quad-channel permanent magnet brushless direct current (QCBLDC) motor. The stator windings are supplied by four independent power converters under quad-channel operation (QCO) mode. After a fault in either one, two, or three channels, further operation of the machine can be continued in triple-channel operation (TCO) mode, dual-channel operation (DCO) mode, or single-channel operation (SCO) mode. In this paper, a novel mathematical model is proposed for a QCBLDC machine. This model takes into account the nonlinearity of a magnetic circuit and all of the couplings between the phases within a given channel, as well as between channels. Based on numerical calculations, the static electromagnetic moment and the coupled fluxes were determined for the individual windings of the variants and work modes being analyzed. A normal work condition can be achieved in the QCO or DCO modes. For the DCO mode, an acceptable case uses a balanced magnetic pull (A and C channels supplied). The DCO A and B type work mode is comparable to the DCO A and C mode with regard to its efficiency in processing electrical energy. The vibroacoustic parameters of this mode, however, are much worse. In fault states, TCO, DCO, and SCO work modes are possible. As the number of active channels decreases, the efficiency of energy processing also decreases. In a critical situation, the motor works in overload mode (SCO mode). Laboratory tests conducted for one of the variants demonstrated that the TCO work mode is characterized by worse vibroacoustic parameters than the DCO A and C mode.