Przemysław Markiewicz

Dr. Przemysław Markiewicz

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 March 2019 in Energies
Verified
Journal Article
Open access
PDF file
RSRoman Sikora
Roman Sikora
PMPrzemysław Markiewicz
Przemysław Markiewicz
The paper presents the results of laboratory tests concerning the measurements of electrical parameters of road lighting luminaires. These measurements were focused on determining the dependence of the electrical parameters of the luminaires versus the changes of the RMS (Root Mean Square) value of the supply voltage and the level of disturbances in the supply voltage. The basic electrical parameters for light-emitting diode (LED) luminaires were analysed with the option of luminous flux adjustment if it existed. During the laboratory measurements, the luminaires were powered from the Agilent 6834B distorted voltage generator within the assumed acceptable range of the changes in the deformation level resulting from the applicable legal provisions for the reproduction of actual power supply conditions.

29 May 2018 in Energies
Verified
Journal Article
Open access
PDF file
RSRoman Sikora
Roman Sikora
PMPrzemysław Markiewicz
Przemysław Markiewicz
WPWiesława Pabjańczyk
Wiesława Pabjańczyk
Before the use of regulated street luminaires with variable power and luminous flux, computations were performed using constant values for their electrical and photometric parameters. At present, where such lighting is in use, it is no longer possible to base calculations on such assumptions. Computations of energy and power losses, for example, need to be performed for all dimming levels and based on the applied regulation algorithm. Based on measurements carried out on regulated luminaires, it was found that certain electrical parameters have a nonlinear dependence on the dimming level. Electrical parameters were also observed to depend on the value of the supply voltage. The results of the measurements are presented in this article. Failure to take account of power losses in computations of the energy efficiency of street lighting in accordance with the applicable EN 13201 standard causes values of energy efficiency indicators to be overstated. Power loss computations are presented in this article for a sample street lighting system with regulated luminaires, for the whole range of dimming levels and additionally for fluctuations of ±10% in the supply voltage. In addition, a mathematical model of a regulated luminaire is constructed with the use of regression methods, and a practical application of that model is described.


12 December 2018 in Sustainability
Verified
Journal Article
Open access
PDF file
RSRoman Sikora
Roman Sikora
PMPrzemysław Markiewicz
Przemysław Markiewicz
WPWiesława Pabjańczyk
Wiesława Pabjańczyk
In accordance with the requirements of PN EN 13201-5 standard for road lighting installation, energy performance indicators should be descripted. In order to calculate energy performance indicators, it is necessary to know the active power of the road lighting system. The above standard does not specify whether active power losses should be taken into account in calculations. The main purpose of the article is to estimate the active power losses in the road lighting installation. The article presents methods for calculating active power losses, taking into account losses in all main elements of the installation. The obtained calculation results show the relationship between active power losses and the power of luminaires, their number and spacing between poles. Calculations of active power losses were made for single-phase and three-phase installations. The active power losses in a three-phase system do not exceed 1.5% and in a single-phase installation they may be greater than 7%. Therefore, in order to obtain exact values of energy performance indicators (and also predict electricity consumption), active power losses should be taken into account in calculations. In addition, a comparative analysis of the effect of luminaires dimming and active power losses on annual CO2 emissions was made. Not taking into account the active power losses in the calculation of the lighting installation’s power, for single-phase installations in particular, understates the calculated value of CO2 emissions by more than 6%.

5 June 2020 in Energies
Verified
Journal Article
Open access
PDF file
RSRoman Sikora
Roman Sikora
PMPrzemysław Markiewicz
Przemysław Markiewicz
Road lighting is an important element of road infrastructure influencing on the road safety. It helps road users to identify potential hazards on the road and reduces the risk of a road accident. Improving the energy efficacy of road lighting installations requires using new technologies. Currently, high-pressure sodium (HPS) lamps are still most commonly used in road lighting. Many of the luminaires with HPS lamps are still in good technical condition and there is no economic justification for replacing them (except improving energy efficacy). One of the methods of improving their energy efficacy is to replace the electromagnetic control gear (ECG) with an electronic ballast (EB). This replacement may affect the colorimetric parameters of the HPS lamps. Two methods to the estimation change of colorimetric parameters after the replacement of ECG to EB were used. The first is CIE TN 001:2014 and the second is ANSI/IES TM-30-15. The article also presents the advantages and disadvantages of these methods in relation to the evaluation of changes in colorimetric parameters of HPS lamps after the replacement of the ECG with an EB. After the replacement of ECG to EB, the smallest reduction of Ra (colour rendering index) occurred for the 150 W lamp by 31.30% and the highest reduction for the 70 W lamp by 65.52%. Considering the changes of the fidelity indicator Rf and gamut indicator Rg, their changes are significantly smaller than for Ra. The smallest change of Rf value was observed for a 150 W lamp (6.00%) and the largest for a 70 W lamp by 25.00%. In case of Rg, similar changes were observed—for 150 W lamp by 9.26% and for 70 W lamp by 21.88%. The ANSI/IES TM-30-15 method is more suitable for evaluating colorimetric parameters after replacing ECG with EB. Using only Ra to evaluate changes of HPS lamps colorimetric parameters after replacing the ballast type can lead to incorrect conclusions concerning changes of colorimetric parameters. Based on the ANSI/IES TM-30-15 method, it has been proposed to introduce the Δf,g indicator which determines the change of colorimetric parameters based on fidelity and gamut colour indicator.

14 August 2025 in Energies
Verified
Journal Article
Open access
PDF file
RSRoman Sikora
Roman Sikora
PMPrzemysław Markiewicz
Przemysław Markiewicz
Ewa KorzeniewskaEwa Korzeniewska
Ewa Korzeniewska
This paper presents an assessment of the impact of maintenance of a road lighting luminaire with a high-pressure sodium lamp and an LED luminaire on the lighting parameters on the road and the energy efficiency of the entire road lighting installation. Improper maintenance of road lighting installations, especially of luminaires, can significantly worsen road traffic safety. In addition, after performing maintenance activities, e.g., after replacing a lamp in the luminaire, the energy consumption of the road lighting installation can increase. Both active and reactive energy can increase. Using the examples of a road luminaire with a high-pressure sodium lamp and an LED luminaire, it was shown that such a phenomenon can occur. An assessment of maintenance in terms of energy performance indicators was performed for the luminaire using the indicators described in the lightning standard and those proposed by the authors of this paper. This approach allows for a comprehensive assessment of maintenance on energy performance indicators—energy efficiency.