Juliana POLATTO

Ms. Juliana POLATTO


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 October 2017 in Antibodies
Verified
Journal Article
Open access
PDF file
LRLeticia Barboza Rocha
Leticia Barboza Rocha
RARúbens Alves
Rúbens Alves
BCBruna Caetano
Bruna Caetano
Lennon PereiraLennon Pereira
Lennon Pereira
TMThais MItsunari
Thais MItsunari
Roxane Maria Fontes PiazzaRoxane Maria Fontes Piazza
Roxane Maria Fontes Piazza
Dengue nonstructural protein 1 (NS1) is a multi-functional glycoprotein with essential functions both in viral replication and modulation of host innate immune responses. NS1 has been established as a good surrogate marker for infection. In the present study, we generated four anti-NS1 monoclonal antibodies against recombinant NS1 protein from dengue virus serotype 2 (DENV2), which were used to map three NS1 epitopes. The sequence 193AVHADMGYWIESALNDT209 was recognized by monoclonal antibodies 2H5 and 4H1BC, which also cross-reacted with Zika virus (ZIKV) protein. On the other hand, the sequence 25VHTWTEQYKFQPES38 was recognized by mAb 4F6 that did not cross react with ZIKV. Lastly, a previously unidentified DENV2 NS1-specific epitope, represented by the sequence 127ELHNQTFLIDGPETAEC143, is described in the present study after reaction with mAb 4H2, which also did not cross react with ZIKV. The selection and characterization of the epitope, specificity of anti-NS1 mAbs, may contribute to the development of diagnostic tools able to differentiate DENV and ZIKV infections.

18 April 2023 in Microorganisms
Verified
Journal Article
Open access
PDF file
ASAndré Valencio Siqueira
André Valencio Siqueira
MSMíriam Aparecida da SILVA
Míriam Aparecida da SILVA
FSFernanda Fernandes dos Santos
Fernanda Fernandes dos Santos
JPJuliana POLATTO
Juliana POLATTO
MMMarcelo F.M. Marcondes
Marcelo F.M. Marcondes
AGAna Cristina Gales
Ana Cristina Gales
The detection of KPC-type carbapenemases is necessary for guiding appropriate antibiotic therapy and the implementation of antimicrobial stewardship and infection control measures. Currently, few tests are capable of differentiating carbapenemase types, restricting the lab reports to their presence or not. The aim of this work was to raise antibodies and develop an ELISA test to detect KPC-2 and its D179 mutants. The ELISA-KPC test was designed using rabbit and mouse polyclonal antibodies. Four different protocols were tested to select the bacterial inoculum with the highest sensitivity and specificity rates. The standardisation procedure was performed using 109 previously characterised clinical isolates, showing 100% of sensitivity and 89% of specificity. The ELISA-KPC detected all isolates producing carbapenemases, including KPC variants displaying the ESBL phenotype such as KPC-33 and -66.

14 January 2022 in Microorganisms
Verified
Journal Article
Open access
PDF file
BCBruna Caetano
Bruna Caetano
MDMarta de Oliveira Domingos
Marta de Oliveira Domingos
MSMíriam Aparecida da SILVA
Míriam Aparecida da SILVA
JSJessika Cristina Alves da Silva
Jessika Cristina Alves da Silva
JPJuliana POLATTO
Juliana POLATTO
Roxane Maria Fontes PiazzaRoxane Maria Fontes Piazza
Roxane Maria Fontes Piazza
The secretion of α-hemolysin by uropathogenic Escherichia coli (UPEC) is commonly associated with the severity of urinary tract infections, which makes it a predictor of poor prognosis among patients. Accordingly, this toxin has become a target for diagnostic tests and therapeutic interventions. However, there are several obstacles associated with the process of α-hemolysin purification, therefore limiting its utilization in scientific investigations. In order to overcome the problems associated with α-hemolysin expression, after in silico prediction, a 20.48 kDa soluble α-hemolysin recombinant denoted rHlyA was constructed. This recombinant is composed by a 182 amino acid sequence localized in the aa542–723 region of the toxin molecule. The antigenic determinants of the rHlyA were estimated by bioinformatics analysis taking into consideration the tertiary form of the toxin, epitope analysis tools, and solubility inference. The results indicated that rHlyA has three antigenic domains localized in the aa555–565, aa600–610, and aa674–717 regions. Functional investigation of rHlyA demonstrated that it has hemolytic activity against sheep red cells, but no cytotoxic effect against epithelial bladder cells. In summary, the results obtained in this study indicate that rHlyA is a soluble recombinant protein that can be used as a tool in studies that aim to understand the mechanisms involved in the hemolytic and cytotoxic activities of α-hemolysin produced by UPEC. In addition, rHlyA can be applied to generate monoclonal and/or polyclonal antibodies that can be utilized in the development of diagnostic tests and therapeutic interventions.

28 February 2023 in Viruses
Verified
Journal Article
Open access
PDF file
CPCarlos Roberto Prudencio
Carlos Roberto Prudencio
VCVivaldo Gomes da Costa
Vivaldo Gomes da Costa
LRLeticia Barboza Rocha
Leticia Barboza Rocha
HCHernan Hermes Monteiro da Costa
Hernan Hermes Monteiro da Costa
DODiego Jose Belato Y Orts
Diego Jose Belato Y Orts
Roxane Maria Fontes PiazzaRoxane Maria Fontes Piazza
Roxane Maria Fontes Piazza
Zika virus (ZIKV), a mosquito-borne pathogen, is an emerging arbovirus associated with sporadic symptomatic cases of great medical concern, particularly among pregnant women and newborns affected with neurological disorders. Serological diagnosis of ZIKV infection is still an unmet challenge due to the co-circulation of the dengue virus, which shares extensive sequence conservation of structural proteins leading to the generation of cross-reactive antibodies. In this study, we aimed to obtain tools for the development of improved serological tests for the detection of ZIKV infection. Polyclonal sera (pAb) and a monoclonal antibody (mAb 2F2) against a recombinant form of the ZIKV nonstructural protein 1 (NS1) allowed the identification of linear peptide epitopes of the NS1 protein. Based on these findings, six chemically synthesized peptides were tested both in dot blot and ELISA assays using convalescent sera collected from ZIKV-infected patients. Two of these peptides specifically detected the presence of ZIKV antibodies and proved to be candidates for the detection of ZIKV-infected subjects. The availability of these tools opens perspectives for the development of NS1-based serological tests with enhanced sensitivity regarding other flaviviruses.

28 September 2023 in Microorganisms
Verified
Journal Article
Open access
PDF file
FCFabiana Fioravante Coelho
Fabiana Fioravante Coelho
MSMíriam Aparecida da SILVA
Míriam Aparecida da SILVA
TLThiciany Blener Lopes
Thiciany Blener Lopes
JPJuliana POLATTO
Juliana POLATTO
NCNatalia Salazar Castro
Natalia Salazar Castro
AFAna Paula Fernandes
Ana Paula Fernandes
SARS-CoV-2 diagnostic tests have become an important tool for pandemic control. Among the alternatives for COVID-19 diagnosis, antigen rapid diagnostic tests (Ag-RDT) are very convenient and widely used. However, as SARS-CoV-2 variants may continuously emerge, the replacement of tests and reagents may be required to maintain the sensitivity of Ag-RDTs. Here, we describe the development and validation of an Ag-RDT during an outbreak of the Omicron variant, including the characterization of a new monoclonal antibody (anti-DTC-N 1B3 mAb) that recognizes the Nucleocapsid protein (N). The anti-DTC-N 1B3 mAb recognized the sequence TFPPTEPKKDKKK located at the C-terminus of the N protein of main SARS-CoV-2 variants of concern. Accordingly, the Ag-RDT prototypes using the anti-DTC-N 1B3 mAB detected all the SARS-CoV-2 variants—Wuhan, Alpha, Gamma, Delta, P2 and Omicron. The performance of the best prototype (sensitivity of 95.2% for samples with Ct ≤ 25; specificity of 98.3% and overall accuracy of 85.0%) met the WHO recommendations. Moreover, results from a patients’ follow-up study indicated that, if performed within the first three days after onset of symptoms, the Ag-RDT displayed 100% sensitivity. Thus, the new mAb and the Ag-RDT developed herein may constitute alternative tools for COVID-19 point-of-care diagnosis and epidemiological surveillance.