Mohsen K. Keshavarz

Dr. Mohsen K. Keshavarz

McGill University
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2018 in Journal of Alloys and Compounds
Verified
Journal Article
Closed access
MRMasoud Roknian
Masoud Roknian
AFArash Fattah-alhosseini
Arash Fattah-alhosseini
SGSeyed Omid Gashti
Seyed Omid Gashti
Mohsen K. KeshavarzMohsen K. Keshavarz
Mohsen K. Keshavarz

1 September 2022 in Journal of Magnesium and Alloys
Verified
Journal Article
Open access
AFArash Fattah-alhosseini
Arash Fattah-alhosseini
RCRazieh Chaharmahali
Razieh Chaharmahali
KBKazem Babaei
Kazem Babaei
MNMeisam Nouri
Meisam Nouri
Mohsen K. KeshavarzMohsen K. Keshavarz
Mohsen K. Keshavarz
Mosab KaseemMosab Kaseem
Mosab Kaseem

15 December 2022 in Coatings
Verified
Journal Article
Open access
PDF file
HMHanane Mozafarnia
Hanane Mozafarnia
AFArash Fattah-alhosseini
Arash Fattah-alhosseini
RCRazieh Chaharmahali
Razieh Chaharmahali
MNMeisam Nouri
Meisam Nouri
Mohsen K. KeshavarzMohsen K. Keshavarz
Mohsen K. Keshavarz
Mosab KaseemMosab Kaseem
Mosab Kaseem
Plasma electrolytic oxidation (PEO) is a promising surface treatment for generating a thick, adherent coating on valve metals using an environmentally friendly alkaline electrolyte. In this study, the PEO method was used to modify the surface of AZ31 Mg alloy. The composite coatings were formed in a phosphate-based electrolyte containing hydroxyapatite nanoparticles (NPs) and different concentrations (1, 2, 3, and 4 g/L) of TiO2 NPs. The results showed that the incorporation of TiO2 NPs in the composite coatings increased the porosity, coating thickness, surface roughness, and surface wettability of the coatings. The corrosion-resistance results of coatings in simulated body fluid (SBF) were tested for up to 72 h and all coatings showed superior corrosion resistance compared to the bare substrate. Among samples containing TiO2, the sample containing 1 g/L TiO2 had the highest inner layer resistance (0.51 kΩ·cm2) and outer resistance (285 kΩ·cm2) and the lowest average friction coefficient (395.5), so it had the best wear and corrosion resistance performance. The antibacterial tests showed that the higher the concentration of TiO2 NPs, the lower the adhesion of bacteria, resulting in enhanced antibacterial properties against S. aureus. The addition of 4 g/L of TiO2 NPs to the electrolyte provided an antibacterial rate of 97.65% for the coating.

1 December 2016 in Journal of Alloys and Compounds
Verified
Journal Article
Closed access
SGS.O. Gashti
S.O. Gashti
AFArash Fattah-alhosseini
Arash Fattah-alhosseini
Yousef MazaheriYousef Mazaheri
Yousef Mazaheri
Mohsen K. KeshavarzMohsen K. Keshavarz
Mohsen K. Keshavarz

27 September 2022 in Ceramics International
Verified
Journal Article
Closed access
YVYemurai Vengesa
Yemurai Vengesa
AFArash Fattah-alhosseini
Arash Fattah-alhosseini
HEHassan Elmkhah
Hassan Elmkhah
OIOmid Imantalab
Omid Imantalab
Mohsen K. KeshavarzMohsen K. Keshavarz
Mohsen K. Keshavarz

1 August 2016 in Journal of Alloys and Compounds
Verified
Journal Article
Closed access
SVS. Vafaeian
S. Vafaeian
AFArash Fattah-alhosseini
Arash Fattah-alhosseini
Mohsen K. KeshavarzMohsen K. Keshavarz
Mohsen K. Keshavarz
Yousef MazaheriYousef Mazaheri
Yousef Mazaheri