Hermann Franz Sussitz

Mr. Hermann Franz Sussitz


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 June 2014 in Biosensors
Verified
Journal Article
Open access
PDF file
VPV. H. Nam Phan
V. H. Nam Phan
HSHermann Franz Sussitz
Hermann Franz Sussitz
PLPeter Lieberzeit
Peter Lieberzeit
Designing Molecularly Imprinted Polymers for sensing proteins is still a somewhat empirical process due to the inherent complexity of protein imprinting. Based on Bovine Serum Albumin as a model analyte, we explored the influence of a range of experimental parameters on the final sensor responses. The optimized polymer contains 70% cross linker. Lower amounts lead to higher sensitivity, but also sensor response times substantially increase (to up to 10 h) at constant imprinting effect (signal ratio MIP/NIP on quartz crystal microbalance—QCM). However, by shifting the polymer properties to more hydrophilic by replacing methacrylic acid by acrylic acid, part of the decreased sensitivity can be recovered leading to appreciable sensor responses. Changing polymer morphology by bulk imprinting and nanoparticle approaches has much lower influence on sensitivity.

10 January 2018 in Sensors
Verified
Journal Article
Open access
PDF file
VPV. H. Nam Phan
V. H. Nam Phan
HSHermann Franz Sussitz
Hermann Franz Sussitz
ELEva Ladenhauf
Eva Ladenhauf
DPDietmar Pum
Dietmar Pum
PLPeter Lieberzeit
Peter Lieberzeit
Herein we report novel approaches to the molecular imprinting of proteins utilizing templates sizing around 10 nm and some 100 nm. The first step comprised synthesizing nanoparticles of molecularly imprinted polymers (MIP) towards bovine serum albumin (BSA) and characterizing them according to size and binding capacity. In a second step, they were utilized as templates. Quartz crystal microbalances (QCM) coated with MIP thin films based on BSA MIP nanoparticles lead to a two-fold increase in sensor responses, compared with the case of directly using the protein as the template. This also established that individual BSA molecules exhibit different “epitopes” for molecular imprinting on their outer surfaces. In light of this knowledge, a possible MIP-based biomimetic assay format was tested by exposing QCM coated with BSA MIP thin films to mixtures of BSA and imprinted and non-imprinted polymer (NIP) nanoparticles. At high protein concentrations (1000 ppm) measurements revealed aggregation behavior, i.e., BSA binding MIP NP onto the MIP surface. This increased sensor responses by more than 30% during proof of concept measurements. At lower a BSA concentration (500 ppm), thin films and particles revealed competitive behavior.

23 May 2019 in Sensors
Verified
Journal Article
Open access
PDF file
MZMartin Zeilinger
Martin Zeilinger
HSHermann Franz Sussitz
Hermann Franz Sussitz
WCWim Cuypers
Wim Cuypers
CJChristoph Jungmann
Christoph Jungmann
PLPeter Lieberzeit
Peter Lieberzeit
Food standards and quality control are important means to ensure public health. In the last decade, melamine has become a rather notorious example of food adulteration: Spiking products with low-cost melamine in order to feign high amino acid content exploits the lack in specificity of the established Kjeldahl method for determining organic nitrogen. This work discusses the responses of a sensor based on quartz crystal microbalances (QCM) coated with molecularly imprinted polymers (MIP) to detect melamine in real life matrices both in a selective and a sensitive manner. Experiments in pure milk revealed no significant sensor responses. However, sensor response increased to a frequency change of −30Hz after diluting the matrix ten times. Systematic evaluation of this effect by experiments in melamine solutions containing bovine serum albumin (BSA) and casein revealed that proteins noticeably influence sensor results. The signal of melamine in water (1600 mg/L) decreases to half of its initial value, if either 1% BSA or casein are present. Higher protein concentrations decrease sensor responses even further. This suggests significant interaction between the analyte and proteins in general. Follow-up experiments revealed that centrifugation of tagged serum samples results in a significant loss of sensor response, thereby further confirming the suspected interaction between protein and melamine.