Previous randomized controlled trials (RCT)s showed similar outcomes in patients with atrial fibrillation (AF) and heart failure with reduced ejection fraction (HFrEF) treated with anti-arrhythmic drugs (AAD) compared to rate control therapy. We sought to evaluate whether catheter ablation is superior to medical therapy in patients with AF and HFrEF. We searched electronic databases for all RCTs that compared catheter ablation and medical therapy (with or without use of AAD). We used random-effects models to summarize the studies. The primary end-point was all-cause mortality. Secondary outcomes included heart failure-related hospitalizations and change in left ventricular ejection fraction (LVEF). We retrieved and summarized 7 randomized controlled trials, enrolling 856 patients (429 in the catheter ablation arm and 427 in the medical therapy arm). Compared with medical therapy (including use of AAD), AF catheter ablation was associated with a significant reduction in mortality (risk ratio 0.50; 95% confidence interval [CI]: 0.34 to 0.74; P = 0.0005) and heart failure-related hospitalizations (risk ratio 0.56; 95% CI: 0.44 to 0.71; P < 0.0001). Furthermore, catheter ablation led to significant improvements in LVEF (weighted mean difference, 7.48; 95% CI: 3.71 to 11.26; P < 0.0001). Compared to medical therapy, including use of AAD, catheter ablation for AF was associated with a significant reduction in mortality and heart failure-related hospitalizations as well as an improvement in LVEF in patients with HFrEF. Larger trials are needed to confirm whether rhythm control with ablation is superior to rate control in patients with AF and heart failure.
Subclinical atrial fibrillation (SCAF) describes asymptomatic episodes of atrial fibrillation (AF) that are detected by cardiac implantable electronic devices (CIED). The increased utilization of CIEDs renders our understanding of SCAF important to clinical practice. Furthermore, 20% of AF present initially as a stroke event and prolonged cardiac monitoring of stroke patients is likely to uncover a significant prevalence of SCAF. New evidence has shown that implanting cardiac monitors into patients with no history of atrial fibrillation but with risk factors for stroke will yield an incidence of SCAF approaching 30–40% at around three years. Atrial high rate episodes lasting longer than five minutes are likely to represent SCAF. SCAF has been associated with an increased risk of stroke that is particularly significant when episodes of SCAF are greater than 23 h in duration. Longer episodes of SCAF are incrementally more likely to progress to episodes of SCAF >23 h as time progresses. While only around 30–40% of SCAF events are temporally related to stroke events, the presence of SCAF likely represents an important risk marker for stroke. Ongoing trials of anticoagulation in patients with SCAF durations less than 24 h will inform clinical practice and are highly anticipated. Further studies are needed to clarify the association between SCAF and clinical outcomes as well as the factors that modify this association.
1 December 2019 in The American Journal of Cardiology
A significant proportion of patients’ experience recurrence of atrial fibrillation (AF) despite pulmonary venous isolation (PVI), especially those with persistent AF. Isolation of the left atrial appendage (LAA) may reduce AF recurrence. The aim of this study was to assess the efficacy of LAA isolation in addition to PVI compared with PVI alone. We conducted a comprehensive search of electronic databases, up to April 21st, 2017, for all studies comparing the effect LAA electrical isolation or ligation in addition to PVI, as opposed to PVI alone, on the recurrence of atrial fibrillation after catheter ablation. We used random‐effects meta‐analysis models to summarize the studies. One RCT and four observational studies enrolling 781 patients were retained. Four studies assessed the added effect of LAA catheter ablation, and one study evaluated the effect of LAA ligation with the aim of LAA electrical isolation. Four studies exclusively enrolled patients with persistent atrial fibrillation and one study predominantly enrolled patients with persistent atrial fibrillation. Follow‐up ranged from 12 to 15 months. The addition of LAA isolation to PVI reduced AF recurrence compared with the latter alone (odds ratio (OR) = 0.19; 95% confidence intervals (CI) = 0.10‐0.37; P < 0.00001). Left atrial appendage isolation was also associated with a reduction in AF recurrence after repeat ablation (OR = 0.40; CI = 0.25‐0.65; P = 0.0003). The addition of LAA isolation to PVI was associated with a decrease in AF recurrence in patients with persistent AF. Further studies are needed to assess the effect on long‐term risk of stroke.
Whether reprogramming of cardiac resynchronization therapy (CRT) to increase electrical synchrony translates into echocardiographic improvement remains unclear. SyncAV is an algorithm that allows fusion of intrinsic conduction with biventricular pacing. We aimed to assess whether reprogramming chronically implanted CRT devices with SyncAV is associated with improved echocardiographic parameters. Patients at a quaternary center with previously implanted CRT devices with a programmable SyncAV algorithm underwent routine electrocardiography-based SyncAV optimization during regular device clinic visits. This analysis included only patients who could be programmed to the SyncAV algorithm (i.e., in sinus rhythm with intrinsic atrioventricular conduction). Echocardiography was performed before and 6 months after CRT optimization. Of 64 consecutive, potentially eligible patients who underwent assessment, 34 who were able to undergo SyncAV programming were included. Their mean age was 74 ± 9 years, 41% were female, and 59% had ischemic cardiomyopathy. The mean time from CRT implant to SyncAV optimization was 17.8 ± 8.5 months. At 6-month follow-up, SyncAV optimization was associated with a significant increase in left ventricular ejection fraction (LVEF) (mean LVEF 36.5% ± 13.3% vs 30.9% ± 13.3%; P < 0.001) and a reduction in left ventricular end-systolic volume (LVESV) (mean LVESV 110.5 ± 57.5 mL vs 89.6 ± 52.4 mL; P < 0.001) compared with baseline existing CRT programming. CRT reprogramming to maximize biventricular fusion pacing significantly increased LVEF and reduced LVESV in patients with chronic CRT devices. Further studies are needed to assess if a continuous fusion pacing algorithm improves long-term clinical outcomes and to identify which patients are most likely to derive benefit.